• 제목/요약/키워드: Pulse studies

검색결과 474건 처리시간 0.021초

맥상 분류 기준에 대한 방법론적 고찰 - "빈호맥학(瀕湖脈學)"을 중심으로 - (The Methodic Study on a Standard of Classification of Pulse Condition -a Focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$-)

  • 이주호;최환수;김철중
    • 한국한의학연구원논문집
    • /
    • 제10권1호
    • /
    • pp.49-61
    • /
    • 2004
  • The Standardization of terms in The Pulse studies(脈學) is a need for development of learning. This study, for the correction of existing misused terms in The Pulse studies, we study on modernly and objectively the terms in The Pulse studies. By a focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$, we studies on the new classification of pulse condition. The error of a existing technical books on Pulse studies begin that the classification of pulse condition is not establish a Standardization. For the correction of existing misused terms in The Pulse studies, we study on the pulse condition is expressed objectively a blood vessel that it is a subject of pulse condition. The expression of blood vessel contain a depth of blood vessel, a speed of pulsation, a curve of blood vessel, thickness of blood vessel, a diameter of blood vessel in expand and contract of blood vessel, a interval in expand and contract of blood vessel, a distinctness on a boundary of blood vessel, a speed of blood flow in blood vessel, a volume of blood flow in blood vessel, a condition of blood in blood vessel, a propelling power of blood vessel. These is standard of the new classification of pulse condition.

  • PDF

사상체질과 맥진기 검사 결과와의 상관성에 대한 연구 - 국내 논문에 대한 체계적 고찰 - (Study on the Correlation between Sasang Constitution and the Data of Pulse Diagnosis Device - A Systematic Review in Korean Articles -)

  • 이혜윤;정아람;손한범;황만석;이정원;김경철;윤영주
    • 동의생리병리학회지
    • /
    • 제26권5호
    • /
    • pp.621-629
    • /
    • 2012
  • This study aimed to examine the possibility of data from pulse diagnosis device to be used for diagnosis of Sasang constitution. Systematic searches of 5 major Korean medical database were conducted for articles published up to May 2012. Searching key word was "Sasang" or "Constitution". Studies dealt with correlation between Sasang constitution and the pulse wave data from pulse diagnosis machine were included. Totally 2886 studies are searched and 3 studies are added from references of evaluated articles. Among them, 12 studies were met our inclusion criteria (2 Xishu Mac, 2 Self-made pulse diagnosis machine, 8 3D-Mac). Three of the eight 3D-Mac studies intended to develop a formula of constitutional differential diagnosis, 2 studies compared variables by Sasang constitution in healthy group and 3 studies compared variables by Sasang constitution in healthy group and special disease group. They all reported some significant variables, however results are not consistent between studies. The accuracy of the formula of constitutional differential diagnosis using 3D-Mac pulse diagnosis devices is 46.0% by now. Improvements in measuring pulse are required to achieve more accurate result and be used for diagnosis of Sasang constitution. Compensating B.M.I. among Sasang constitutional groups and separating constitutional pulse factors from acquired characteristics are also needed in further study.

Marx 펄스발생기를 응용한 소형 고전압 급준 펄스 발생장치 (Fast Rise Time High Voltage Pulse Generator Applying The Marx Generator)

  • 박승록;정석환;김진규;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.72-78
    • /
    • 2001
  • A compact size high voltage pulse generator with nanosecond rise time has been designed and investigated experimentally. The inductance of a pulse generator can be reduced by fixing the Marx generator and pulse forming network components into a single cylindrical unit. As a result, nanosecond rise time about $8{\sim}10[ns]$ and pulse width of several hundred [ns] can be obtained from a modified Marx pulse generator. And parametric studies showed that the rise time of the output pulse was depended little on the change of the load resistance and the charging capacitance while, the pulse width of the output pulse was depended greatly upon the change of the load resistance and the charging capacitance. The theoretical showed the possibility to design the laboratory-size pulse generator very fast rising time and a proper pulse width by minimizing stray inductance and varying resistance and capacitance.

  • PDF

맥진 연구의 국내 동향에 대한 고찰 (Review of the Domestic Trend of Pulse Diagnosis Studies in Korea)

  • 강세영
    • 대한한방내과학회지
    • /
    • 제40권6호
    • /
    • pp.1152-1168
    • /
    • 2019
  • Objectives: The aim of this study was to present several proposals for future pulse diagnosis practice and research by investigating the trend of pulse diagnosis studies in Korea. Methods: We searched online medical databases, including National Discovery for Science Leaders (NDSL), the Oriental Medicine Advanced Searching Integrated System (OASIS), the Research Information Sharing Service (RISS), and the Korean Traditional Knowledge Portal (KTKP), for pulse diagnosis articles in Korea. We selected articles on pulse diagnosis but excluded duplicate articles, articles irrelevant to pulse diagnosis, and articles published in foreign countries. Results: In the first screening, 801 articles were selected. We found 251 articles and classified them according to category. The medical engineering field had 148 articles. A total of 24 articles were related to algorithms for pulse wave detection, 34 to sensors, five to pressurization technology, 16 to systems, 11 to remote medical service, five to mobiles, nine to trends, and 44 to basic research. The Korean medicine field had 103 articles. A total of 41 articles were devoted to literature reviews, 20 to case reports, 11 to constitutional medicine, six to experimental studies, and 25 to relevant research. Conclusion: More efforts to practice pulse diagnosis for various diseases should be made and the results actively published.

맥진기를 활용한 대사증후군 대상 임상연구 고찰 (A Review on Clinical Studies on Metabolic Disease Using a Pulse Tonometry Device)

  • 김지혜;전영주
    • 대한한방내과학회지
    • /
    • 제39권4호
    • /
    • pp.612-623
    • /
    • 2018
  • Objective: The aim of this research was to investigate the current status and limitations of the clinical use of a pulse tonometry device (PTD). Methods: We searched online medical databases, including Oriental Medicine Advanced Searching Integrated System (OASIS), Research Information Sharing Service (RISS), DataBase Periodical Information Academic (DBpia) and PubMed, for clinical studies of metabolic diseases that used PTD. We selected articles on the clinical application of the PTD but excluded duplicate articles, clinical studies without the PTD, and non-clinical studies. In the first screening, 551 articles were selected. Ultimately, we found 10 articles and classified the articles according to the following diseases: hyperlipidemia, diabetes, overweight and obesity, hypertension, and metabolic disease. Results: Of the 10 selected articles, 4 were focused on hypertension. Two articles were focused on overweight or obesity and two articles were focused on the metabolic disease. Conclusions: This study was the first attempt to conduct a systematic review on clinical studies of metabolic disease using the PTD as a primary outcome. We suggest that the standard of pulse wave parameters and operating procedures for the PTD should be further developed. The results of this study are expected to be used as basic information for the planning and progression of clinical studies of metabolic syndrome using PTD.

Study on the Selection of Representative Pulse Wave

  • Kim, Jong-Yeol;Shin, Sang-Hoon
    • 대한한의학회지
    • /
    • 제29권5호
    • /
    • pp.104-110
    • /
    • 2008
  • Objectives : The purpose of this study is to develop the method of selecting representative pulse wave. Methods : The pulse waves were acquired at the right and the left Guan point(關部) with 1420 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results : In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions : So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave.

  • PDF

C/SiC 복합재료 제조시 Pulse-CVI에서 증착변수의 영향 연구 (Studies on Effects of Deposition Parameters in Manufacturing of C/Sic composites by Pulse-CVI)

  • 김용탁;김영준;정귀영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.141-143
    • /
    • 2001
  • Ceramic fiber-reinforced composites have good mechanical properties in hardness and durability. In this study, we studied the formation of SiC/C composites from methyltrichlorosilane and hydrogen by the Pulse-chemical vapor infiltration(PCVI) to deposit silicon carbide around the changes of the amount of deposit. SiC/C composites formed at $950^{\circ}C$, 20torr, Pulse-times (5s/60s). SEM of the cross sectional area of semple showed deposited silicon carbide around fibers.

  • PDF

A Novel Frequency-to-Digital Converter Using Pulse-Shrinking

  • Park, Jin-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.220-223
    • /
    • 2003
  • In this paper, a new frequency-to-digital converter without an analog element is proposed. The proposed circuit consists of pulse-shrinking elements, latches and D flip-flops, and the operation is based on frequency comparison by the pulse-shrinking element. In the proposed circuit, the resolution of digital output can be easily improved by increasing the number of the pulse-shrinking elements. The FDC performance is improved in viewpoints of operating speed and chip area. In designed FDC, error of frequency-to-digital conversion is less than 0.1 %.

냉자극에 대한 맥율 변화 예비 연구 (A Feasibility Study of Pulse Rate Per Respiration as an Indicator for the Reaction to Cold Stress)

  • 배장한;전영주;김현호;김재욱
    • 동의생리병리학회지
    • /
    • 제28권6호
    • /
    • pp.668-673
    • /
    • 2014
  • Cold and Heat pattern identification(CHPI) in traditional East Asian medicine(TEAM) is one of the major indicator to distinguish characteristics of disease and to determine treatment method. Basic parameters to determine CHPI include the pulse rate, respiration rate, and pulse power. Studies to associate physiological responses of human body by cold stress(CS) with CHPI in TEAM were rarely done so far. This study aims to explore the effects of cold stress on pulse signal via a feasibility study for three subjects and investigate some indices which can reflect autonomic nerve reaction(ANR). We measured radial pulse signals and respiration signal of the investigated subjects before the CS, during the CS which continues for 5 minutes, and immediately after the CS, respectively. Finally, we analyzed the pulse rate (P), respiration rate (R), pulse power, pulse depth, and pulse rate per respiration (P/R ratio). As a result, the P/R ratio showed a consistently decreasing tendency through the CS stimulation process, while other parameters behaved more complex and in subject-specific ways. It implies that, among candidate parameters, the P/R ratio is a simple but the most probable parameter that can be used as the ANR indicator. This result is also consistent with the theory in TEAM scripts, in which the P/R ratio is predicted to be a direct indicator for the CHPI. This pilot study shows that P/R ratio can be more appropriately associated with the ANR than heart rate or respiration rate alone. Extensive studies will be necessary to verify or confirm the P/R ratio as an appropriate and well defined parameter for ANR.

문헌을 통한 맥상의 물리적 요소 분석 (Analysis of Physical Quantification of Pulse Types by Pulse Diagnosis Literatures)

  • 유현희;이시우;이전;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1381-1387
    • /
    • 2007
  • Pulse diagnosis that is one of important examination methods in traditional oriental medicine has been investigated for the standardization in many ways. Pulse analyzer device and clinical studies have been tried for this purpose. Additionally, literature study has significance for this standardization. In this study, we analyzed pulse types in literatures from the viewpoint of physics. We refered to Maijing, Maijue, siyanjuyao, Binhumaixue, Yixuerumen, zhenjiazhengyan. We established some physical factors for analysis. This factors that can be detected through pulse analyzer are depth, speed, power, width, and length. In this study, we defined 18 kinds of pulse types among 28 total types by physical factors. Furthermore, 6 kinds of pulse types were classified as basic pulse from these. The results of this study will improve the pulse analyzer to detect these pulse types.