• Title/Summary/Keyword: Pulse shape

Search Result 439, Processing Time 0.023 seconds

Theoretical Analysis of Impact of Q-switch Rise Time on Output Pulse Performance in an Ytterbium-doped Actively Q-switched Fiber Laser (이터븀 첨가 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향에 대한 이론적 분석)

  • Jeon, Jinwoo;Lee, Junsu;Lee, Ju Han
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.58-63
    • /
    • 2013
  • A theoretical analysis of the impact of rise time of a Q-switch on the output pulse performance is carried out in an Ytterbium-doped actively Q-switched fiber laser. The finite difference time domain (FDTD) method is used to numerically simulate the Q-switched fiber laser. It is shown that stable Gaussian-like pulse shape can be generated when the Q-switch rise time is increased and pulse repetition rate is enlarged.

A Parametric Sturdy on Double Slit Type Rupture Disc of Pulse Separation Device (펄스분리장치의 이중 슬릿형 파열판 매개변수 연구)

  • Han, Houk-Seop;Cho, Won-Man;Koo, Song-Hoe;Lee, Bang-Eop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.105-112
    • /
    • 2010
  • Dual Pulse Rocket Motor is a solid rocket motor with two grains separated by a bulkhead and rupture disc. The elasto-plastic explicit dynamic analysis of rupture disc was conducted by finite element method. The effect of the slit geometry of a rupture disc was analyzed for rupture time and shape by the parametric study. The results can be used to control the rupture pressure by the change the slit geometry of a rupture disc.

  • PDF

Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters (충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측)

  • Jang, Kyeong-Min;Jung, Eun-Sang;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

Analysis of Magnetic Flux Path and Static Thrust Force of the Double-Side Linear Pulse Motor (양측식 리니어 펄스 모터의 자로와 정특성 해석)

  • Kim, Seong-Jong;Lee, Eun-Ung;Kim, Seong-Heon;Kim, Jun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.9
    • /
    • pp.493-498
    • /
    • 2002
  • Double-side linear pulse motor(DSLPM) has more advantages than single-side linear pulse motor because noise and vibration can be considerably decreased by countervailing the normal forces, which is generated between two stators and mover. However, DSLPM has more complicated magnetic flux path and layout of stator pole toot/mover tooth rather than single-side linear pulse motor In this paper, DSLPM is designed and fabricated by considering the air gap magnetic density, shape of tooth and slot. In order to verify the characteristics of DSLPM, the air gap magnetic flux density is analyzed by 2D FEM and the magnetic flux path is analyzed by 3D FEM. Also the static thrust forces is obtained with the analyzed results.

Observation of Plasma Shape by Continuous dc and Pulsed dc (직류 방전과 펄스 직류 방전에 의한 플라즈마 형상 관찰)

  • Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.42 no.3
    • /
    • pp.133-138
    • /
    • 2009
  • Effects of bipolar pulse driving frequency between 50 kHz and 250 kHz on the discharge shapes were analyzed by measuring plasma characteristics by OES (Optical Emission Spectroscopy) and Langmuir probe. Plasma characteristics were modeled by a simple electric field analysis and fluid plasma modeling. Discharge shapes by a continuous dc and bipolar pulsed dc were different as a dome-type and a vertical column-type at the cathode. From OES, the intensity of 811.5 nm wavelength, the one of the main peaks of Ar, decreased to about 43% from a continuous dc to 100 kHz. For increasing from 100 kHz to 250 kHz, the intensity of 811.5 nm wavelength also decreased by 46%. The electron density decreased by 74% and the electron temperature increased by 36% at the specific position due to the smaller and denser discharge shape for increasing pulse frequency. Through the numerical analysis, the negative glow shape of a continuous dc were similar to the electric potential distribution by FEM (Finite Element Method). For the bipolar pulsed dc, we found that the electron temperature increased to maximum 10 eV due to the voltage spikes by the fast electron acceleration generated in pre-sheath. This may induce the electrons and ions from plasma to increase the energetic substrate bombardment for the dense thin film growth.

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Axial Pressing Method Using Pulse Magnetizing Field for the Preparation of Nd-Ee-B Sintered Magnets (펄스자장을 이용한 고이방화 Nd-Fe-B자석의 종축자장성형방법)

  • Kim, Dong-Hwan;Kang, Byung-Kil;Jang, Dong-Youl;Kim, Andrew S.;Kim, Sang-Myun;Jang, T.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.182-186
    • /
    • 2003
  • A new axial pressing method using pulse magnetizing field was studied to improve the remanence of Nd-Fe-B sintered magnets. In order to make near-net shape green compacts of butterfly, disk, or coin magnets, conventional axial-type pressing has been normally used. However, compared to the transverse-type pressing, it is not possible to obtain higher remanence by this method because the magnetic alignment of powder begins to deteriorate when the density of green compacts increases over a critical value. On the other hand, we found that an axial pressing under pulse magnetizing field was very effective to increase the degree of magnetic alignment of powder, yielding remanences even higher than those obtained by the transverse pressing. In this study, it was revealed that appropriate tapping density and how to apply pulse magnetic held were important to improve the grain alignment and thus remanence of Nd-Fe-B sintered magnet.

A study on The Pulse taking diagnostics of Nan Jing 1-23 Nan (난경(難經) 1-23난중(難中) 맥학조(脈學條)에 관한 연구(硏究))

  • Kim, Bup-Jin;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.131-154
    • /
    • 2000
  • Nan Jing(Difficult Classic), as a catechism, describes in detail and deeply the ideas in Nei Jing(Huangdi's Internal Classic). The description of Nan Jing is focused on basic theories including theories about some disease and is excellent in identification and analysis. The contents of Nan Jing are as follows: 1-23 Nan-pulse and pulse condition, 24~29 Nan-channels and collaterals, 30~47 Nan-viscera and bowels(Zang Fu organs), 48~61 Nan-disease, 62~68 Nan-acupuncture points, 69~91 Nan-acupuncture. Especially, diagnosis techniques in Nan Jing make 'Only method of cunkou pulse taking' that is a technique for feeling the pulse widely applied in these days in Oriental medicine clear. Thus, this book adjusts the theory of pulse and pulse condition given in 1~23 Nan of 'The Study of Nan Jing' in order to enhance an understanding about the theory of pulse and pulse condition. The text of 1~23 Nan about pulse lore centers on all pulse of human body interconnected each other and cunkou, both ends of the pulse, and contrasts regular pulse with irregular pulse. 1. 10 Nan describes the theory about five kinds of evils and hardness and softness, and unique pulse condition of each bowels. 2. 13 Nan explains that the relative difficulty of medical treatment is determined by the degree of balance or unbalance among three factors-colors, pulse and pulse condition, flesh shape. 3. 14 Nan divides pulse and pulse condition into slow pulse and rapid pulse, and explains separately abnormality, great loss of semen, death caused by slow pulse, and abnormality, great loss of semen, death caused by rapid pulse. 4. 15 Nan about taut pulse(弦), full pulse(鉤), floating pulse(毛), deep pulse(石脈) describes that pulse and pulse condition differs according to four seasons. Therefore, Nan Jing establishes clearly techniques of feeling the pulse in 'Only method of cunkou pulse taking(獨取寸口)' and advances the theory of Nei Jing. Futhermore, Nan Jing is more valuable in that it suggests unique theory different with Nei Jing.

  • PDF

Considerations on an Oriental Medical Doctor like Indentation System (한의사 맥진 가압력 재현에 대한 고찰)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, the indentation pressure is one of the most important factors as well as the change of pulse shape and the distribution of pressure via time. But, on the oriental medical doctor's indentation pressure control, the understandings of the neurophysiological meanings and mechanisms have been lacked. So, in this paper, we considered on these issues and then proposed a proper system which can imitate the OMD's indentation pressure control mechanisms. As a result, both tactile information and kinesthetic information were found to be essential to the indentation pressure control so that a system, which can measure both the physical indent pressure and the displacement of an indentation arm, has been proposed. With this proposed system, while the indentation was being controlled through the moving step number of the step motor, the physical indentation pres sure and displacement of the indentation arm were measured. From these measured data, the relationships between the moving step number and both physical indentation pressure and displacement were revealed to have linear characteristics in early phase and to have nonlinear characteristics in latter phase. Additionally, three types of graph were generated whose X axis means the moving step number, the physical indentation pressure and the displacement respectively and Y axis means the pulse pressure. By comparing these graphs, we come to conclude that different concepts on indentation pressure control cause different diagnostic results on floating/sinking degrees for the same subject. Consequently, an indentation system for the pulse diagnosis should be able to provide both the tactile information and kinesthetic information, that is, the physical indentation pressure and the displacement of the indentation arm. In future, the proposed system should be optimized to the pulse diagnosis environment and how to combine the both information for more reliable diagnosis should be studied.

  • PDF