• Title/Summary/Keyword: Pulse shape

Search Result 439, Processing Time 0.023 seconds

Pulse shape discrimination using a stilbene scintillator array coupled to a large-area SiPM array for hand-held dual particle imager applications

  • Jihwan Boo;Mark D. Hammig;Manhee Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.648-654
    • /
    • 2023
  • A dual-particle imager (DPI) is configured in a hand-held form factor, then one can efficiently and conveniently deploy the DPI to detect the presence of special nuclear materials (SNM) and identify any isotopic variations that differ from their natural abundances. Here we show that by maximizing the areal coupling between a pixelated scintillator array and the partitioned photosensor readout such as a silicon photomultiplier (SiPM), the information utilization of the gamma-ray and neutron information in the radiation field can be enhanced, thus enabling one to rapidly acquire spatial maps of the distributions on gamma-ray and neutron emitters.

Analysis of Propagation Characteristics in Microstriplines Using the FDTD (FDTD를 사용한 마이크로스트립라인 전파특성 해석)

  • 류종인;김용진;박영태;이상설
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.869-872
    • /
    • 1999
  • As integrated circuits are developed, the crosstalk and the pulse distortion have been major problems in the design. In this paper. the PML and one-point resistive source are applied. This paper deal with the microstripline circuit which has the gap and three microstripline. Obtaining the Propagation pulse shape in microstripline, we prove that the use of the FDTD in the microstripline is valid.

  • PDF

Some aspects of scintillation mechanism in organic molecular dielectrics

  • Galunov, N.Z.;Grinev, B.V.;Tarasenko, O.A.;Martynenko, E.V.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.85-89
    • /
    • 2005
  • Aspects of the scintillation mechanism in organic systems obtained on the base of precise measurements of the radioluminescence pulse shape are discussed. It shown that the process of scintillation light pulse formation is mainly determined by initial conditions of exited states generation.

The Effect of Welding Parameters on the Weld Shape in Pulsed GTA Welding of a STS304L Stainless Steel Capsule (STS304L 캡슐의 펄스형 GTA 용접에서 용접변수들이 용접부 형상에 미치는 영향)

  • Lee, Hyoung-Keun;Han, Hyon-Soo;Son, Kwang-Jae
    • Journal of Welding and Joining
    • /
    • v.25 no.5
    • /
    • pp.64-71
    • /
    • 2007
  • The aim of this paper is to investigate the effects of welding parameters on the weld shape in seal-welding of STS304L capsule for manufacturing a radioisotope source which is widely used in nondestructive testing of metal structures using gamma ray. Pulsed gas tungsten arc (Pulsed GTA) welding is performed for thin cross sectional area of the capsule. Seven welding parameters including current waveform parameters and arc length etc. are selected as main process parameters using design of experiment. The weld shape such as bead width, penetration depth, weld area, aspect ratio and area rate is investigated to assess the effects of welding parameters. As results, the combination of pulse duty/welding speed largely affects on bead width, penetration depth, area and aspect ratio. Finally, it is concluded that the key parameters are the combination of pulse duty/welding speed, base current and arc length, and their optimal conditions are 50%/1.77mm/s, 6.4A and 1 mm.

Survey Study about Sasangin's Characteristics of Face, Voice, Skin and Pulse Diagnosis (사상인(四象人)의 안면, 음성, 피부 및 맥진 특성에 관한 설문조사 연구)

  • Lee, Jun-Hee;Kim, Yun-Hee;Hwang, Min-Woo;Kim, Jong-Yeol;Lee, Eui-Ju;Song, Il-Byung;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.126-143
    • /
    • 2007
  • 1. Objectives The purpose of this study is to find out the grade of practical use, the important element and the significant characteristics of Sasangin' s face, voice, skin and pulse diagnostic impression, in Sasang constitutional clinical diagnosis. 2. Methods We analysed the survey data about Sasangin' s face, voice, skin and pulse diagnostic impression, drawn up by specialist in Sasang constitutional medicine. 3. Results and Conclusions (1) In the application degree of face feature, the case which it was applied with 20-40% and 40-60% were 16 people(43.2%) respectively. In voice, the case applied with 0-20% was 19 people(51.4%), in skin, 0-20% and 20-40% were 14 people(37.8%) respectively and in pulse diagnosis, 0-20% were 25 people(73.0%). (2) In constitutional diagnosis, the important element of face were 'frontal whole shape', 'whole impression' and 'size and shape of eye, ear, mose and mouth', the important element of voice 'speed of speech', 'purity and impurity' and 'pitch', the important element of skin 'thickness', 'feel of touch' and 'size of skin pores' and the important element of pulse diagnosis 'speed of pulse', 'sinking and floating' and 'weakness and firmness'. (3) The important face characteristics of Taeyangin were 'bright eye', 'broad forehead' and 'strong impression', Soyangin 'protruding forehead', 'thin and small lips', 'narrowing and sharp chin', Taeumin 'thick lips', 'flat face', 'large eye, nose, ear and mouth' and Soeumin 'long and slender face', 'downward slanting eyes' and 'small eye, nose, ear and mouth', The important voice characteristics of Taeyangin were 'loud' and 'clear', Soyangin 'rapid' and 'high-pitched tone', Taeumin 'chick', 'slow' and 'low-pitched tone' and Soeumin 'small and feeble' and 'slow'. The important skin characteristics of Taeyangin were 'thin' and 'white', Soyangin 'thin', 'smooth' and 'elastic', Taeumin 'thick', 'large skin-pore', 'coarse' and Soeumin 'soft', 'thin' and 'subtle skin-pore'. The important pulse characteristics of Taeyangin were 'rapid' and 'large', Soyangin 'rapid' and 'floating', Taeumin 'tense', 'long' and 'solid' and Soeumin 'fine', 'weak' and 'slow'.

  • PDF

Determination of $^{241}Pu$ in Environmental Samples Using Liquid Scintillation Counting System (액체섬광계수기를 이용한 환경시료중 $^{241}Pu$분석)

  • Lee, Myung-Ho;Hong, Kwang-Hee;Choi, Yong-Ho;Kim, Sang-Bog;Choi, Geun-Sik;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 1996
  • An optimized method for determining beta-emitting $^{241}Pu$ in the presence of alpha-emitting nuclides was developed using a liquid scintillation counting system. Pulse shape analysis (PSA) level was set using pulse-shape discrimination method and the $^{241}Pu$ counting channel was adjusted for maximum value of figure of merit using the 241pu standard source. The volume of scintillant was determined for the maximum value of counting efficiency. This optimized method has been applied to environmental samples to measure concentration of $^{241}Pu$ in soils and mosses. Also it has been identified the origin of Pu deposited in Korea from the activity ratio of $^{241}Pu/^{239,\;240}Pu$.

  • PDF

Phoswich Detector for Simultaneous Measuring Alpha/beta Particles (알파/베타선 동시측정용 phoswich 검출기)

  • Kim, Gye-Hong;Park, Chan-Hee;Lee, Kune-Woo;Jung, Chong-Hun;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  • PDF

Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer

  • Kim, Chanho;Yeom, Jung-Yeol;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.53-63
    • /
    • 2019
  • Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a high-speed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a $^{137}Cs$ gamma source and a $^{252}Cf$ neutron source. We implemented digital signal processing techniques to apply two PSD methods - the charge comparison (CC) method and the constant time discrimination (CTD) method - to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in $300{\pm}100keVee$, $500{\pm}100keVee$, and $700{\pm}100keVee$ energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.