• 제목/요약/키워드: Pulse plasma

검색결과 497건 처리시간 0.025초

Lateral growth of PEO films on Al7050 alloy in 0.1 M NaAlO2

  • Moon, Sungmo;Kim, Gi Yeob
    • 한국표면공학회지
    • /
    • 제54권4호
    • /
    • pp.200-208
    • /
    • 2021
  • This paper investigated generation behavior of micro-arcs and growth behavior of PEO films on the AA7050 disc specimen in 0.1 M NaAlO2 solution under the application of 1200 Hz anodic pulse current. Morphologies, thickness and surface roughness of PEO films were examined at the edge part and central part separately. Micro-arcs were generated first at the edge part and then moved towards the central part with PEO treatment time, indicating lateral growth of PEO films. The lateral growth resulted in uniform PEO thickness of about 5 ㎛ and surface roughness of about 0.5 ㎛. Moving of the arcs from the edge towards the central part appeared only one time and large size arcs were generated at the edge before completing the central part with small size micro-arcs. This suggests that vertical growth starts before completing the lateral growth. Large size arcs generated at the edge resulted in the formation of relatively large size pores within the PEO films on the AA7050 disc specimen.

Development of a neural network method for measuring the energy spectrum of a pulsed electron beam, based on Bremsstrahlung X-Ray

  • Sohrabi, Mohsen;Ayoobian, Navid;Shirani, Babak
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.266-272
    • /
    • 2021
  • In the pulsed electron beam generators, such as plasma focus devices and linear induction accelerators whose electron pulse width is in the range of nanosecond and less, as well as in cases where there is no direct access to electron beam, like runaway electrons in Tokamaks, measurement of the electron energy spectrum is a technical challenge. In such cases, the indirect measurement of the electron spectrum by using the bremsstrahlung radiation spectrum associated with it, is an appropriate solution. The problem with this method is that the matrix equation between the two spectrums is an ill-conditioned equation, which results in errors of the measured X-ray spectrum to be propagated with a large coefficient in the estimated electron spectrum. In this study, a method based on the neural network and the MCNP code is presented and evaluated to recover the electron spectrum from the X-ray generated by collision of the electron beam with a target. Multilayer perceptron network showed good accuracy in electron spectrum recovery, so that for the X-ray spectrum with errors of 3% and 10%, the network estimated the electron spectrum with an average standard error of 8% and 11%, on all of the energy intervals.

Electroabsorption modulator-integrated distributed Bragg reflector laser diode for C-band WDM-based networks

  • Oh-Kee Kwon;Chul-Wook Lee;Ki-Soo Kim
    • ETRI Journal
    • /
    • 제45권1호
    • /
    • pp.163-170
    • /
    • 2023
  • We report an electroabsorption modulator (EAM)-integrated distributed Bragg reflector laser diode (DBR-LD) capable of supporting a high data rate and a wide wavelength tuning. The DBR-LD contains two tuning elements, plasma and heater tunings, both of which are implemented in the DBR section, which have blue-shift and red-shift in the Bragg wavelength through a current injection, respectively. The light created from the DBR-LD is intensity-modulated through the EAM voltage, which is integrated monolithically with the DBRLD using a butt-joint coupling method. The fabricated chip shows a threshold current of approximately 8 mA, tuning range of greater than 30 nm, and static extinction ratio of higher than 20 dB while maintaining a side mode suppression ratio of greater than 40 dB under a window of 1550 nm. To evaluate its modulation properties, the chip was bonded onto a mount including a radiofrequency line and a load resistor showing clear eye openings at data rates of 25 Gb/s nonreturn-to-zero and 50 Gb/s pulse amplitude modulation 4-level, respectively.

Lupus anticoagulant hypoprothrombinemia syndrome associated with a hemorrhagic ovarian cyst in a girl with systemic lupus erythematosus: a case report

  • Min Hwa Son;Hyung Eun Yim
    • Childhood Kidney Diseases
    • /
    • 제28권2호
    • /
    • pp.80-85
    • /
    • 2024
  • Lupus anticoagulant hypoprothrombinemia syndrome (LAHPS) is a rare entity characterized by the presence of lupus anticoagulant (LA) and prothrombin (factor II) deficiency. It may cause severe bleeding contrary to classical antiphospholipid syndrome. Here, we report a case of LAHPS presenting with a hemorrhagic ovarian cyst in a 17-year-old girl with systemic lupus erythematosus (SLE) nephritis. She had been followed up for 8 years. Her first manifestation of SLE was prolonged gingival bleeding after tooth extraction at 9 years of age. During the follow-up period, she had neither severe bleeding nor thrombotic complications despite a positive LA and a prolonged activated partial thromboplastin time (aPTT). At this visit, the patient presented with colicky abdominal pain, a hemorrhagic ovarian cyst, a prolonged prothrombin time, a prolonged aPTT, a low factor II level, and a positive LA, leading to the diagnosis of LAHPS. While a hemorrhagic ovarian cyst resolved completely in 3 months, she received oral pill, transfusions of red blood cells and plasma, and intravenous cyclophosphamide pulse therapy in combination with glucocorticoids due to persistent menorrhagia, anemia, prolonged aPTT, and lupus flaring. Thus, LAHPS needs to be considered in SLE patients with positive LA and prolonged aPTT.

배리어방전을 이용한 메탄전환반응에서 함산소 가스가 전환율 및 생성물변화에 미치는 영향 (The Conversion of Methane with Oxygenated Gases using Atmospheric Dielectric Barrier Discharge)

  • 이광식;여영구;최재욱;이화웅;송형근;나병기
    • 에너지공학
    • /
    • 제15권1호
    • /
    • pp.52-59
    • /
    • 2006
  • 본 연구에서는 배리어 방전을 이용한 메탄전환 반응에서 수소 및 다른 탄화수소류 화합물의 생성율과 분포에 관하여 알아보았다. 반응기의 외부전극과 내부전극은 SUS로 만들어진 원통형을 사용하였으며, 배리어 방전을 일으키기 위해서 전극 사이에 알루미나 튜브를 사용하였다. 전환된 메탄으로부터 다양한 생성물을 얻기 위해서 유입가스의 조성, 유량변화, 주파수 및 전압을 변화시켜 주면서 실험하였다. 플라즈마 반응에 의한 주요한 생성물들은 에틸렌, 에탄, 프로판, 부탄, 수소, 일산화탄소, 그리고 이산화탄소 등으로 나타났다. 비활성 가스의 사용과 인가전압의 증가에 의해서 메탄 전환율 및 탄화수소류의 선택도가 향상되었다. 유입가스 내에 수증기의 첨가로 인해서 메탄의 전환율 및 수소의 수율이 증가되었다. 수증기 첨가 반응에서 에탄, 프로판 그리고 부탄은 더 높은 전압을 인가하였을 때 수율이 증가하였으며, 아세틸렌과 에틸렌은 보다 낮은 전압에서 수율이 증가함을 알 수 있었다.

IBC형 태양전지 제작을 위한 p-a-Si:H 증착층의 파이버 레이저 가공에 관한 연구 (Study on Fiber Laser Annealing of p-a-Si:H Deposition Layer for the Fabrication of Interdigitated Back Contact Solar Cells)

  • 김성철;이영석;한규민;문인용;권태영;경도현;김영국;허종규;윤기찬;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.430-430
    • /
    • 2008
  • Using multi plasma enhanced chemical vapor deposition system (Multi-PECVD), p-a-Si:H deposition layer as a $p^+$ region which was annealed by laser (Q-switched fiber laser, $\lambda$ = 1064 nm) on an n-type single crystalline Si (100) plane circle wafer was prepared as new doping method for single crystalline interdigitated back contact (IBC) solar cells. As lots of earlier studies implemented, most cases dealt with the excimer (excited dimer) laserannealing or crystallization of boron with the ultraviolet wavelength range and $10^{-9}$ sec pulse duration. In this study, the Q-switched fiber laser which has higher power, longer wavelength of infrared range ($\lambda$ = 1064 nm) and longer pulse duration of $10^{-8}$ sec than excimer laser was introduced for uniformly deposited p-a-Si:H layer to be annealed and to make sheet resistance expectable as an important process for IBC solar cell $p^+$ layer on a polished n-type Si circle wafer. A $525{\mu}m$ thick n-type Si semiconductor circle wafer of (100) plane which was dipped in a buffered hydrofluoric acid solution for 30 seconds was mounted on the Multi-PECVD system for p-a-Si:H deposition layer with the ratio of $SiH_4:H_2:B_2H_6$ = 30:120:30, at $200^{\circ}C$, 50 W power, 0.2 Torr pressure for 20 minutes. 15 mm $\times$ 15 mm size laser cut samples were annealed by fiber laser with different sets of power levels and frequencies. By comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 50 mm/s of mark speed, 160 kHz of period, 21 % of power level with continuous wave mode of scanner lens showed the features of small difference of lifetime and lowering sheet resistance than before the fiber laser treatment with not much surface damages. Diode level device was made to confirm these experimental results by measuring C-V, I-V characteristics. Uniform and expectable boron doped layer can play an important role to predict the efficiency during the fabricating process of IBC solar cells.

  • PDF

Midazolam을 이용한 의식진정시 flumazenil의 투여경로에 따른 생징후 및 행동양상의 비교 연구 (A COMPARATIVE STUDY ON THE VITAL SIGN AND BEHAVIOR APPEARANCE DEPENDING ON THE ROUTE OF FLUMAZENIL ADMINISTRATION IN CONSCIOUS SEDATION BY MIDAZOLAM)

  • 김현식;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.159-167
    • /
    • 2002
  • 본 연구의 목적은 midazolam을 이용한 의식진정 시 길항제인 flumazenil의 투여경로에 따른 효과와 안전성을 평가하기 위함이다. 연구대상으로는 $22{\sim}24$세의 건강한 15명의 자원자를 이용하였으며, 그들은 midazolam 0.2mg/Kg을 비강내 분무하여 진정하였으며, midazolam 투여 40분 후 길항제인 flumazenil 0.2mg을 정맥 내 투여 및 비강 내 투여하였다. 각 투여경로의 안전성과 효과를 평가하기 위해 다음과 같은 관찰이 실시되었다. 대상의 생징후를 관찰하기 위해 pulse oxymeter(Nellcor symphony N-3000, Nellcor Puritan CO., USA)을 이용하여 $SaO_2$ 및 맥박수를 관찰하였고, 전자혈압계(Heartcare 200, National CO., Japan)을 이용하여 이완기 및 수축기 혈압을 관찰하였다. 또한 실험대상의 주관적 평가를 위해 visual analogue scale(VAS)를 이용하여, 진정, 수면, 피로 그리고 태도에 대해 주관적인 평가를 실시하였다. 모든 대상은 특이할 부작용없이 회복되었다. 연구결과를 요약하면 다음과 같다. 1. 비강내 분무된 flumazenil은 정맥내 투여된 flumazenil에 비해 빠른 회복을 보였으나, 곧이어 정맥내 투여에 비해 깊은 수면상태에 빠졌다. 2. 비강내 투여된 flumazenil 및 정적내 투여된 경우 모두 주의할 부작용 및 생징후의 악화는 관찰되지 않았다. 회복의 목적으로 비강내 분무된 flumazenil의 결과로 미루어 볼 때, midazolam을 이용한 의식진정시 flumazenil의 비강 내 분무를 통해 보다 안전하고, 효과적인 의식진정하 치과치료가 가능하리라 사료된다. 하지만, flumazenil의 적절한 용량 및 효과를 알기위해, midazolam과 flumazenil의 혈장농도를 평가하는 약물동력학적 연구가 계속되어야 하리라 사료된다.

  • PDF

박동류 및 비박동류에 의한 체외순환의 비교 (Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass)

  • 선경;백광제;김요한;임창영;김광택;김학제;김형묵
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

Simple one-step synthesis of carbon nanoparticles from aliphatic alcohols and n-hexane by stable solution plasma process

  • Park, Choon-Sang;Kum, Dae Sub;Kim, Jong Cheol;Shin, Jun-Goo;Kim, Hyun-Jin;Jung, Eun Young;Kim, Dong Ha;Kim, Daseulbi;Bae, Gyu Tae;Kim, Jae Young;Shin, Bhum Jae;Tae, Heung-Sik
    • Carbon letters
    • /
    • 제28권
    • /
    • pp.31-37
    • /
    • 2018
  • This paper examines a simple one-step and catalyst-free method for synthesizing carbon nanoparticles from aliphatic alcohols and n-hexane with linear molecule formations by using a stable solution plasma process with a bipolar pulse and an external resistor. When the external resistor is adopted, it is observed that the current spikes are dramatically decreased, which induced production of a more stable discharge. Six aliphatic linear alcohols (methanol-hexanol) containing carbon with oxygen sources are studied as possible precursors for the massive production of carbon nanoparticles. Additional study is also carried out with the use of n-hexane containing many carbons without an oxygen source in order to enhance the formation of carbon nanoparticles and to eliminate unwanted oxygen effects. The obtained carbon nanoparticles are characterized with field emission-scanning electron microscopy, energy dispersive X-ray spectroscopy, and Raman spectroscopy. The results show that with increasing carbon ratios in alcohol content, the synthesis rate of carbon nanoparticles is increased, whereas the size of the carbon nanoparticles is decreased. Moreover, the degree of graphitization of the carbon nanoparticles synthesized from 1-hexanol and n-hexane with a high carbon (C)/oxygen (O) ratio and low or no oxygen is observed to be greater than that of the carbon nanoparticles synthesized from the corresponding materials with a low C/O ratio.

Nd:$YVO_4$ 레이저 빔을 이용한 인듐 주석 산화물 직접 묘화 기술 (Direct Patterning Technology of Indium Tin Oxide Layer using Nd:$YVO_4$ Laser Beam)

  • 김광호;권상직
    • 대한전자공학회논문지SD
    • /
    • 제45권11호
    • /
    • pp.8-12
    • /
    • 2008
  • AC PDP에 사용되는 ITO 전극의 공정시간을 단축시키고 생산성을 향상시키기 위해서 Nd:$YVO_4$ laser를 사용하여 ITO 전극 패턴을 하였다. ITO etchant를 사용하여 ITO 전극패턴을 형성한 샘플과 비교해서 laser를 사용하여 제작한 샘플은 ITO 라인 끝 부분에 shoulder와 물결무늬가 형성되었다. shoulder와 물결무늬의 제거를 위해서 laser의 펄스반복율과 스캔 속도에 변화를 주었다. 또한 shoulder와 물결무늬를 갖는 ITO 전극이 PDP에 주는 영향을 알아보기 위해서 방전특성분석을 하였다. 실험결과 40 kHz와 500 mm/s를 기본 조건으로 결정하였다. 본 실험을 통하여 레이저를 이용한 PDP용 ITO 전극막의 직접 패터닝 가능성을 확인할 수 있었다.