• Title/Summary/Keyword: Pulse oximeter

Search Result 81, Processing Time 0.026 seconds

Comparative efficacy of three topical anesthetics on 7-11-year-old children: a randomized clinical study

  • Dasarraju, Rupak Kumar;SVSG, Nirmala
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.1
    • /
    • pp.29-37
    • /
    • 2020
  • Background: This study evaluated the efficacy of three intraoral topical anesthetics in reducing the injection needle prick pain from local anesthetic among children aged 7-11 years old. Methods: It is a prospective, Interventional, parallel design, single-blind, randomized clinical trial in which subjects (n=90) aged 7-11 years were included in the study based on an inclusion criteria. Subjects were divided into three groups based on computer-generated randomization with an allocation ratio of 1:1:1. Groups A, B, and C received benzocaine 20% jelly (Mucopain gel, ICPA health products Ltd, Ankleshwar, India), cetacaine anesthetic liquid (Cetylite Industries, Inc, Pennsauken, NJ), and EMLA cream (2% AstraZeneca UK Ltd, Luton, UK), respectively, according to manufacturer's instructions, for 1 minute prior to local anesthetic injection. After application of topical anesthetic agent, for all the groups, baseline pre-operative (prior to topical anesthetic administration) and post-operative scores (after local anesthetic administration) of pulse rate was recorded using Pulse oximeter (Gibson, Fingertip Pulse Oximeter, MD300C29, Beijing Choice Electronic). Peri-operative (i.e., during the administration of local anesthesia) scores were recorded using Face, Legs, Activity, Cry, Consolability (FLACC) Scale, Modified Children hospital of Eastern Ontario Pain Scale (CPS) behavior rating scale, and Faces Pain Scale (FPS-R) - Revised (For self-reported pain). Direct self-reported and physiological measures were ascertained using FPS-R - Revised and Pulse oximeter, respectively, whereas CPS and FLACC scales assessed behavioral measures. To test the mean difference between the three groups, a one way ANOVA with post hoc tests was used. For statistical significance, a two-tailed probability value of P < 0.05 was considered as significant. Results: The Cetacaine group had significantly lower pain scores for self-report (P < 0.001), behavioral, and physiological measures (P < 0.001) than the other two groups. However, there was no significant difference between the Benzocaine group and EMLA group during palatal injection prick. Conclusion: Cetacaine can be considered as an effective topical anesthetic agent compared to benzocaine 20% jelly (Mucopain gel) and EMLA cream.

PULSE RATE AND OXYGEN SATURATION IN CHILDREN DURING ROUTINE RESTORATIVE DENTISTRY (소아 치과치료시 심박동과 동맥혈 산소포화도의 변화)

  • Kim, Ha-Na;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.65-72
    • /
    • 2008
  • Pulse oximeter to monitor oxygen saturation during pediatric dental sedations enables early detection of hypoxemia. The purpose of this study was to monitor the hemoglobin oxygen saturation level and pulse rate of nonmedicated pediatric patients during routine restorative procedures to study the effect of procedure and treated jaw. We obtained data from 53 children treated at the Department of Pediatric Dentistry, Chonbuk national university hospital. Pulse rate and oxygen saturation were measured and recorded using pulse oximetry at each step of treatment. The results are as follows: 1. In non-anesthesia group, steep increase of pulse rate was observed during rubber dam application in the maxilla and during cavity preparation in the mandible. 2. In anesthesia group, pulse rate started to decrease after the rubber dam application in the maxilla, while its decrease observed since cavity preparation step in the mandible. 3. In non-anesthesia group, oxygen saturation level was relatively constant during all steps in the maxilla, but in mandible, it was higher during operation compared to its pre and post operation baseline. 4. In anesthesia group, oxygen saturation level was observed at 99% level through all steps in both jaw groups, and there was no statistical significance between the maxilla and the mandible groups(p>0.05). The purpose of this study was to evaluate the effect of routine dental treatment on the pulse rate and oxygen saturation level in nonmedicated pediatric patients during routine restorative procedures in the maxilla and mandible.

  • PDF

A Light Control Algorithm for Pulse Oximeter (펄스옥시미터 시스템의 광조절 알고리즘 구성 방법)

  • Kang, Min-Soo;Lee, Jeong-Whan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.229-231
    • /
    • 2012
  • 본 논문에서는 펄스옥시미터 시스템의 측정 신뢰성 향상을 위해 Perfusion Index값을 이용한 광량조절의 방법을 제시한다. 본 방법은 펄스옥시미터의 광출력 값의 조정을 미약한 신호 상황에 대한 적응 가능한 광출력을 줄 수 있으며, 산소포화도 측정값의 변화율에 직접적으로 영향을 주는 광량을 보다 정확하게 조절하여 안정적인 측정이 가능하다. 또한 미약한 신호의 측정을 일괄적으로 조절 가능한 기능을 통해 다양한 사람들에게 사용되는 펄스옥시미터의 특성상 보다 정확한 값을 제공할 수 있다.

  • PDF

Smart watch with reflective Pulse Oximeter (반사형 Pulse Oximeter를 통한 스마트 손목시계)

  • Lee, Hooseok;Thap, Tharoeun;Moon, Chanki;Nam, Yunyoung;Lee, Jinseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.1046-1048
    • /
    • 2015
  • 본 논문은 웨어러블 디바이스의 한 종류로써의 스마트와치에 적용할 수 있는 헬스케어 기술에 대한 제안이다. RED LED와 IR LED를 통해 얻어진 신호로부터 아날로그 필터 증폭을 통해 얻어진 PPG신호를 이용하여 생체신호인 심박수와 $SpO_2$를 측정하여 보았다. 이 신호를 블루투스 통신을 통해 PC에서 데이터를 받아 보았고, 추후에 스마트폰과 연동하여 실용적으로 사용 될 수 있다.

On a Reading Aloud to Relieve the Decrease in Blood Oxygen Saturation when Jogging

  • Tian, Zhixing;Bae, MyungJin
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.95-100
    • /
    • 2020
  • Recently, the problem of hypoxia caused by jogging is attracting attention. To solve this problem, this paper proposed a new solution. This paper proved that as a vocalization method of reading aloud, it is possible to increase air intake and activate lung function to exchange more air and obtain more oxygen. Then, blood oxygen saturation was used as an evaluation index for the body's oxygen content level to prove its effectiveness. A photoelectric pulse oximeter developed on the basis of different light absorption principles in blood was used to test blood oxygen saturation. Experimental results show that a certain degree of hypoxia is induced when a lot of oxygen is required due to jogging. Therefore, it was proved that the new vocal breathing method by reading books can increase the blood oxygen saturation of the body and improve the hypoxia of the body. Reading vocal breathing is a simple and efficient oxygen saturation recovery breathing method.

Pulse wave analysis system using wrist type oximeter for u-Health service (u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

Analysis of Photoplethysmographic Waveform for Assessment of Pulpal Blood Flow in Children (소아 환자의 치수 혈류 평가를 위한 광용적맥파 파형 분석)

  • Kim, Hyo-Eun;Shin, Teo Jeon;Kong, Hyoun-Joong;Kim, Pil-Jong;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.2
    • /
    • pp.158-165
    • /
    • 2016
  • The purpose of this study was to analyze photoplethysmographic waveforms from pulse oximeter using raw data of red and infrared light and investigate the reference values of parameters (Height, Width50, Maximum slope, Minimum slope, Area) for evaluating pulpal blood flow in maxillary central incisors with normal pulp vitality in children. The study was performed in 30 pediatric patients, aged 7-16 years old, using pulse oximeter (MEKICS Co., Ltd, Korea) combined with a custom-made sensor. The raw data was obtained and recorded by custom-made software and analyzed by LabChart (v.7.3, ADInstruments, Germany) offline. In this study, we analyzed photoplethysmographic waveforms from pulse oximeter applied to maxillary central incisor for assessment of pulpal blood flow and suggested several reference values of young permanent maxillary central incisor with normal pulp. On average, the waveform of red light was higher, stiffer and wider than that of infrared light. Future studies about reference values for other normal teeth and the teeth with impaired pulp vitality are needed.

Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation (독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출)

  • Jeon, Hak-Jae;Kim, Jeong-Do;Lim, Seung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

SpO2 Measurement Algorithm for PPG Signal with Motion Artifacts (동잡음을 가진 PPG 센서에서의 산소포화도 측정 알고리즘)

  • Jang, Seong-Jin;Choi, Kue-Lak;Park, Keun-Hae;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.192-198
    • /
    • 2018
  • Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it because Masimo's patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The proposed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF