• Title/Summary/Keyword: Pulse echo method

Search Result 149, Processing Time 0.028 seconds

Corrosion visualization under organic coating using laser ultrasonic propagation imaging

  • Shi, Anseob;Park, Jinhwan;Lee, Heesoo;Choi, Yunshil;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.301-309
    • /
    • 2022
  • Protective coatings are most widely used anticorrosive structures for steel structures. The corrosion under the coating damages the host material, but this damage is completely hidden. Therefore, a field-applicable under-coating-corrosion visualization method has been desired for a long time. Laser ultrasonic technology has been studied in various fields as an in situ nondestructive inspection method. In this study, a comparative analysis was carried out between a guided-wave ultrasonic propagation imager (UPI) and pulse-echo UPI, which have the potential to be used in the field of under-coating-corrosion management. Both guided-wave UPI and pulse-echo UPI were able to successfully visualize the corrosion. Regarding the field application, the guided-wave UPI performing Q-switch laser scanning and piezoelectric sensing by magnetic attachment exhibited advantages owing to the larger distance and incident angle in the laser measurement than those of the pulse-echo UPI. Regarding the corrosion visualization methods, the combination of adjacent wave subtraction and variable time window amplitude mapping (VTWAM) provided acceptable results for the guided-wave UPI, while VTWAM was sufficient for the pule-echo UPI. In addition, the capability of multiple sensing in a single channel of the guided-wave UPI could improve the field applicability as well as the relatively smaller size of the system. Thus, we propose a guided-wave UPI as a tool for under-coating-corrosion management.

Pulse-echo Response of Ultrasonic Transducer Fabricated by PZT-Polymer 3-3 Type Composite Resonator for Distance Measurement Applications (거리측정용 PZT-고분자 3-3형 복합압전체 트랜스듀서의 펄스에코 응답특성)

  • 주용관;박정학;최헌일;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.205-208
    • /
    • 1995
  • PZT powders were prepared by the molten salt synthesis method. The porous PZT specimens were prepared from a mixture of PZT and Polyvinylalcohol(PVA) powders by BURPS(Burnout Plastic Sphere) technique. The pulse-echo response of PZT-polymer 3-3 type composite transducer with various PVA wt.% were studied, The fall time of pulse-echo response of PZT-polymer 3-3 type composite transducer was shorten to that of solid PZT-maded transducer. Therefore, a good transmitting and receiving properties could be obtained. The distance between transducer and reflector was in good agreement both solid PZT and PZT-polymer 3-3 type composite fabricated transducer.

  • PDF

Pulse-echo Response of Ultrasonic Transducer Fabricated by Porous Piezoceramics PZT Resonator (다공질 압전소자(PZT)로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • Joo, Yong-Khoan;Lee, Su-Ho;Park, Jung-Hak;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.358-360
    • /
    • 1995
  • PZT powders were prepared by the molten salt synthesis method. The porous PZT specimens were prepared from a mixture of PZT and polyvinylalcohol(PVA) powders by BURPS(Burnout Plastic Sphere) technique. The pulse-echo response of porous PZT transducer with various PVA wt.% were studied. The fall time of pulse-echo response of porous PZT transducer was shorten to that of solid PZT-maded transducer. Therefore, a good transmitting and receiving properties could be obtained. The distance between transducer and reflector was in good agreement both solid PZT and porous PZT fabricated transducer.

  • PDF

Pulse-echo response of 1-3 type piezoelectric composite transducers for distance measurement (거리 측정용 1-3형 복합압전체 트랜스듀서의 펄스에코 응답 특성)

  • 최헌일;박정학;이수호;사공건
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.211-216
    • /
    • 1995
  • In this study, the piezoelectric ceramics/polymer composite transducers with 1-3 connectivity have been studied. A piezoelectric ceramics PZT prepared by Wet-Dry Combination method was used as a filler in polymer matrix Eccogel. We've got the pulse-echo response for 1-3 type piezc-electric composite transducers in water. It was shown that the transmitting and receiving sensitivity of 1-3 type piezoelectric composite transducers could be improved in comparison with that- of solid PZT transducers. The reason is for that 1-3 type Piezoelectric composites have low dielectric constant and density. There was in a good agreement between the resonant frequencies calculated from one period and observed results on the Ultrasonic Transducer Analyzer. According to these results we could be figured out the distance in water by virture of the pulse-echo response.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducers (압전 세라믹-고분자 1-3형 복합 압전체 트랜스듀서의 펄스에코 특성)

  • Choi, H.I.;Park, J.H.;Lee, S.H.;SaGong, G.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1403-1405
    • /
    • 1994
  • In this study, the piezoelectric transducers with 1-3 connectivity have maded. A piezoelectric ceramic PZT prepared by Wet-Dry Combination method is used as a filler in Eccogel polymer matrix. The pulse-echo response for 1-3 type composite transducers were carried out in water. It was observed that the transmitting and receiving sensitivity of 1-3 type composite transducers were improved in comparison with that or solid PZT transducer. The reason is for that 1-3 composites have a hish piezoelectric voltage coefficients, The period of pulse-echo response for the transducer is in a good agreement with the resonant frequency of self-maded composite transducer.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducer for a Level Limit Switch Applications (Level Limit스위치용 1-3형 복합압전체 트랜스듀서의 펄스-에코응답특성)

  • Choi, H.I.;Sohn, M.H.;Kim, H.K.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.224-228
    • /
    • 2002
  • In this study, the piezoelectric ceramics PZT powder was synthesized by the Wet-Dry combination method. Flexible 1-3 type composite specimens were fabricated with the piezoceramics PZT filler phase and Eccogel polymer matrix phase. This paper represents the pulse-echo response of the 1-3 type composite transducer to check it out to investigate a basic property regarding a level limit switch. The acoustic impedance of 1-3 type composite was improved than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with the self-made 1-3 type composites resonator was better than that of the solid PZT transducer.

  • PDF

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

Reduction of Susceptibility Artifact in MR Gradient Echo Imaging (MR Gradient Echo 영상술에서 자화율에 의한 에러의 감소에 관한 연구)

  • Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.19-23
    • /
    • 1990
  • A new technique for reducing the susceptibility artifact in gradient echo imaging which uses a tailored RF pulse is proposed. It is applied to the case of imaging where artifacts and distortions arise due to the high local magnetic field inhomogeneity i. e., the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method using a tailored RF pulse is proposed. Applications of this method in imaging are given and experimental results obtained using an human volunteer with a 2.0 T KAIS NMR system are presented.

  • PDF

Homogeneity of lightweight aggregate concrete assessed using ultrasonic-echo sensing

  • Wang, H.Y.;Li, L.S.;Chen, S.H.;Weng, C.F.
    • Computers and Concrete
    • /
    • v.6 no.3
    • /
    • pp.225-234
    • /
    • 2009
  • Dredged silt from reservoirs in southern Taiwan was sintered to make lightweight aggregates (LWA), which were then used to produce lightweight aggregate concrete (LWAC).This study aimed to assess the compressive strength and homogeneity of LWAC using ultrasonic-echo sensing. Concrete specimens were prepared using aggregates of four different particle density, namely 800, 1100, 1300 and 2650 kg/$m^3$. The LWAC specimens were cylindrical and a square wall with core specimens drilled. Besides compressive strength test, ultrasonic-echo sensing was employed to examine the ultrasonic pulse velocity and homogeneity of the wall specimens and to explore the relationship between compressive strength and ultrasonic pulse velocity. Results show that LWA, due to its lower relative density, causes bloating, thus resulting in uneven distribution of aggregates and poor homogeneity. LWAC mixtures using LWA of particle density 1300 kg/$m^3$ show the most even distribution of aggregates and hence best homogeneity as well as highest compressive strength of 63.5 MPa. In addition, measurements obtained using ultrasonic-echo sensing and traditional ultrasonic method show little difference, supporting that ultrasonic-echo sensing can indeed perform non-destructive, fast and accurate assessment of LWAC homogeneity.

Determination of the Optimum-Bandwidth of Chirp-Signal for Pulse Compression Technique (펄스압축 기술을 위한 chirp 신호의 최적대역폭 결정)

  • Ko, Dae-Sik;Moon, Gun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.5-9
    • /
    • 1997
  • In this paper, when we use the chirp signal as input signal of ultrasonic signal system the technique for determining the bandwidth of the chirp signal that maximizes the amplitude of the compressed ultrasonic echo signal has been studied. In ultrasonic signal processing systems, the signal-to-noise ratio of the echo signal can be too low due to damping and scattering of the ultrasonic wave during transmission. Method of pulse compression using chirp signal is a means to increase the signal-to-noise ratio in ultrasonic pulse-echo systems. Simulation and experimental results showed that the output signal of ultrasonic system was increased by pulse width of chirp signal and the optimum-bandwidth of the chirp signal was 1.15 times larger than the bandwidth of the ultrasonic system.

  • PDF