• Title/Summary/Keyword: Pulse diagnosis analysis

Search Result 131, Processing Time 0.028 seconds

Clinical Investigation of Survey and Test in Korean Oriental Pediatrics (한방소아과 설문지 및 검사에 관한 임상현황연구)

  • Hwang, Young-Jun;Kim, Ki-Bong;Min, Sang-Yeon;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.1
    • /
    • pp.25-34
    • /
    • 2008
  • Objectives The purpose of this study is to investigate whether Korean oriental pediatrics hospitals are using their feedback surveys to improve their medical conditions. Methods We selected 24 oriental medicine university hospitals and sent surveys to investigate. 15 of those surveys were analyzed. Results The results were classified as follows; Only 9 of university hospital said that they are currently using their feedback surveys to improve their services. Question for asking the purpose of doing their feedback surveys, 58.3% of hospital responded to get some information for diagnosis, 25% of them said to see the progress of treatment of specific disease, and 16.7% answered for using their data to the further studies. The question about the reason why hospital were need to make these feedback surveys, 46.2% of them answered to apply better service, 38.4% of them said to post medical journal. The question for asking what do oriental medical hospitals check from feedback surveys, 40% of them said they check Ryodoraku, 33.3% was pulse diagnostic apparatus, EAV(Electro-puncture According to Voll) was 26.7%. The classification according to purpose of test resulted as follows; information for diagnosis was 48.1%, the progress of a disease was 37.3%. In addition oriental medical test there were blood test, radiological test, brain waves test, Hair Tissue Mineral Analysis(HTMA), ultrasonic test, body composition analysis. Conclusions Further clinical research is necessary for improvement of using the feedback survey effectively.

  • PDF

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

Cold-Heat and Excess-Deficiency Pattern Identification Based on Questionnaire, Pulse, and Tongue in Cancer Patients: A Feasibility Study (암 환자 대상 설문지, 맥진기, 설진기 결과를 활용한 한열허실변증에 대한 예비 연구)

  • Choi, Yujin;Kim, Soo-Dam;Kwon, Ojin;Park, Hyo-Ju;Kim, JiHye;Choi, Woosu;Ko, Myung-Hyun;Ha, Su-Jeung;Song, Si-Yeon;Park, So-Jung;Yoo, Hwa-Seung;Jeong, Mi-Kyung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Objectives: This pilot study aimed to evaluate the agreement between traditional face-to-face Korean medicine (KM) pattern identification and non-face-to-face KM pattern identification using the data from related questionnaires, tongue image, and pulse features in patients with cancer. Methods: From January to June 2020, 16 participants with a cancer diagnosis were recruited at the one Korean medicine hospital. Three experienced Korean medicine doctors independently diagnosed the participants whether they belong to the cold pattern or not, heat pattern or not, deficiency pattern or not, and excess pattern or not. Another researcher collected KM pattern related data using questionnaires including Cold-Heat Pattern Identification (CHPI), tongue image analysis system, and pulse analyzer. Collected KM pattern related data without participants' identifier was provided for the three Korean medicine doctors in random order, and non-face-to-face KM pattern identification was carried out. The kappa value between face-to-face and non-face-to-face pattern identification was calculated. Results: From the face-to-face pattern identification, there were 13/3 cold/non-cold pattern, 4/12 heat/non-heat pattern, 14/2 deficiency/non-deficiency pattern, and 0/16 excess/non-excess pattern participants. In cold/non-cold pattern, kappa value was 0.455 (sensitivity: 0.85, specificity: 0.67, accuracy: 0.81). In heat/non-heat pattern, the kappa value was 0.429 (sensitivity: 0.75, specificity: 0.72, accuracy: 0.75). The kappa value of deficiency/non-deficiency and excess/non-excess pattern was not calculated because of the few participants of non-deficiency, and excess pattern. Conclusions: The agreement between traditional face-to-face pattern identification and non-face-to-face pattern identification seems to be moderate. The non-face-to-face pattern identification using questionnaires, tongue, and pulse features may feasible for the large clinical study.

A study for Oriental Medicine Pulse diagnosis of pulse wave analysis on left/right blood vessel (좌우 맥파분석을 통한 혈관특성 및 한의맥진연구)

  • Lee, Yu-Jung;Woo, Young-Jae;Lee, Hae-Jung;Jeon, Young-Ju;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1968_1969
    • /
    • 2009
  • 한의학에서 맥진을 하는 위치인 좌, 우 요골동맥상의 촌(寸), 관(關), 척(尺) 위치는 손목에 있는 요골 경상돌기(styloid preocess) 부근의 볼록한 지점인 고골(高骨)을 기준으로 맥이 느껴지는 위치를 검지, 중지, 약지를 이용해 찾는다. 각각의 위치는 한의학적인 관점에서 각기 다른 장부의 기능과 연결되며 그 차이를 인지하여 맥을 진단하는데 그 결과에 따라 병증을 진단하는 요소로 활용되게 된다. 그러나 생리학적으로 좌, 우 요골동맥의 차이는 크지 않다고 알려져 있으며 차이에 대한 연구도 많지 않다. 본 연구에서는 기존연구에서 밝혀진 좌, 우 요골동맥의 혈류속도의 차이를 근거로 한의사 맥진시 센서 역할을 하는 손가락에서 감지된 좌, 우 맥진위치의 차이가 실제 맥진기에서도 나타나는지를 측정을 통해 확인 해 보고자 한다. 건강한 20대 남자 135명을 대상으로 맥파를 측정하여 맥파 파라메터 중 차이를 보이는 파라메터를 통계분석하였다. 그 결과, 11개의 파라메터가 좌, 우 맥진위치에서 차이를 보이는 것을 확인하였다. 차이를 보이는 변수는 특정 변수로 한정되지 않고 맥압과 관련된 (h1~5) 변수와 피크가 나타나는 시간의 변수, 맥파 파형의 면적 등 다양한 변수에서 차이를 확인할 수 있었다.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

Image Evaluation and Association Analysis of the Cardiovascular Disease of the Degree of Pancreatic Steatosis in Ultrasonography

  • Cho, Jin-Young;Ye, Soo-Young;Ko, Seong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • Increasing fat tissue of obese people, increases the rate of cardiovascular disease, diabetes, metabolic syndromes and dyslipidemia. An increase in the focal tissue of pancreas is a known risk factor of these diseases. Although there exists sufficient research on the diagnosis and treatment of pancreatic cancer, studies have been done on fatty pancreas. In this study, based on ultrasound imaging and using a texture characteristic of GLCM, fatty pancreas was divided into three categories: mild, moderate and severe. We compared and analyzed the three groups was by Pancreatic ultrasonography and body characteristics, serological tests, pressure and the degree of arteriosclerosis, against normal control group. The following parameters of control and test groups were measured: WC (waist circumference),BMI (body mass index), TC (total cholesterol), TG (triglyceride), HDL-C (High-density lipoprotein cholesterol) and LDL-C (Low-density lipoprotein cholesterol), SBP (systolic blood pressure), BST (Blood Sugar Test) and aortic PWV (pulse wave velocity). We observed the values correspondingly increasing fat deposition. However, ABI (Ankle Brachial pressure index) stenosis and HDL-C levels decreased with increasing fat deposit (p <0.05); a drop in these parameters are known to be harmful to the human body. The difference in texture characteristics between normal control group and pancreatic fatty group (mild, moderate, and severe) was statistically confirmed. Ultrasound imaging of pancreatic steatosis categorized the disease as mild, moderate and severe based on the characteristic texture. In conclusion, we observed on increase in metabolic syndrome, dyslipidemia, and arteriosclerosis, proportional to the degree of pancreatic fat deposition. The escalation of these diseases was confirmed and was directly related with predictors of cardiovascular diseases.

Elevated Levels of Serum Lipids Accelerate Biological Vascular Aging evaluated by the Second Derivative of Photoplethysmogram Waveform in the Middle-Age Adults (중년 성인남녀의 혈중 지질농도가 가속도맥파에 미치는 영향)

  • Nam, Tong-Hyun;Koh, Hyung-Kyun;Park, Young-Bae
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.126-137
    • /
    • 2002
  • Objective : There is accumulating data that cardiovascular diseases, including hypertension, cerebro-vascular accident, coronary heart disease, relate to atherosclerotic changes. Increased serum levels of lipids could play a role in these circumstances. the SDPTG(the second derivative of photoplethysmogram waveform) is noninvasive methods for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. Methods : To study the effects of serum lipid levels on the SDPTG in the middle-age adults, data on serum lipid levels and the SDPTG were collected in 80 healthy middle age with varying serum lipid concentrations. Biological vascular age was assessed using the SDPTG. the SDPTG consists of an a, b, c, and d wave in systole and an e wave in diastole; an SDPTG aging index(Al) was calculated as (b-c-d-e)/a. Results : Serum triglyceride, total cholesterol, total lipid, phospholipid, HDL cholesterol levels were respectively and significantly correlated with SDPTG Al. Serum lipid levels and blood pressure are age-dependent and the SDPTG is blood pressure-dependent. Restricting analysis to age and blood pressure yield strong positive correlations between serum triglyceride, total lipid levels and SDPTG Al, but no correlations between serum total cholesterol, phospholipid levels and SDPTG Al. Conclusion : The results of this study suggest that preventive acupuncture programs or herbal medications for reducing serum lipid, especially triglyceride, levels in middle-age should include a evaluation of biological vascular aging with the second derivative of photoplethysmogram waveform.

  • PDF

Design and Implementation of Circuit Analyzer for Electronics Appliance Troubleshooting and Diagnosis using Curve Tracer Technology (파형추적기술을 이용한 전자기기 고장진단용 회로분석기 설계 및 구현)

  • 장재철;양규식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.273-280
    • /
    • 1999
  • This paper presents the design and implementation of circuit analyzer system for the convenient troubleshooting and diagnosis of the electronics appliance using the curve tracer technology of analog signature analysis. The circuit analyzer provides advanced troubleshooting capabilities to simplify testing newer technology components such as CMOS and MOS circuits, its built-in pulse generator lets thoroughly troubleshoot gate-fired devices such as SCRs, TRIACs and optocouplers. The circuit analyzer while the power to the circuitry testing is turned of, so that avoid an accidental short that could cause further damage, its allow to analyze the impedance state of a solid-state component, which makes it perfect for finding leakage or substrate damage that has brought a system or PCB down prematurely. Because it can compare suspect components to known-good equivalents, it's verified the ideal application for troubleshooting when documentation is missing or incomplete.

  • PDF

Functional Magnetic Resonance Imaging in the Diagnosis of Locally Recurrent Prostate Cancer: Are All Pulse Sequences Helpful?

  • Liao, Xiao-Li;Wei, Jun-Bao;Li, Yong-Qiang;Zhong, Jian-Hong;Liao, Cheng-Cheng;Wei, Chang-Yuan
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1110-1118
    • /
    • 2018
  • Objective: To perform a meta-analysis to quantitatively assess functional magnetic resonance imaging (MRI) in the diagnosis of locally recurrent prostate cancer. Materials and Methods: A comprehensive search of the PubMed, Embase, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews was conducted from January 1, 1995 to December 31, 2016. Diagnostic accuracy was quantitatively pooled for all studies by using hierarchical logistic regression modeling, including bivariate modeling and hierarchical summary receiver operating characteristic (HSROC) curves (AUCs). The Z test was used to determine whether adding functional MRI to T2-weighted imaging (T2WI) results in significantly increased diagnostic sensitivity and specificity. Results: Meta-analysis of 13 studies involving 826 patients who underwent radical prostatectomy showed a pooled sensitivity and specificity of 91%, and the AUC was 0.96. Meta-analysis of 7 studies involving 329 patients who underwent radiotherapy showed a pooled sensitivity of 80% and specificity of 81%, and the AUC was 0.88. Meta-analysis of 11 studies reporting 1669 sextant biopsies from patients who underwent radiotherapy showed a pooled sensitivity of 54% and specificity of 91%, and the AUC was 0.85. Sensitivity after radiotherapy was significantly higher when diffusion-weighted MRI data were combined with T2WI than when only T2WI results were used. This was true when meta-analysis was performed on a per-patient basis (p = 0.027) or per sextant biopsy (p = 0.046). A similar result was found when $^1H$-magnetic resonance spectroscopy ($^1H$-MRS) data were combined with T2WI and sextant biopsy was the unit of analysis (p = 0.036). Conclusion: Functional MRI data may not strengthen the ability of T2WI to detect locally recurrent prostate cancer in patients who have undergone radical prostatectomy. By contrast, diffusion-weight MRI and $^1H$-MRS data may improve the sensitivity of T2WI for patients who have undergone radiotherapy.

The Relationship between Oriental Medical Diagnosis and Arteriosclerosis by Carotid-Ankle Vascular Index(CAVI) in Acute Cerebral Infarction Patients (CAVI를 이용한 급성기 중풍환자의 Arteriosclerosis와 한방변증의 관련성 연구)

  • Choi, Won-Woo;Kim, Mi-Young;Kim, Young-Jee;Lee, Seung-Yeop;Leem, Jung-Tae;Kim, Chang-Hyun;Min, In-Kyu;Park, Sung-Wook;Jung, Woo-Sang;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-No;Kim, Young-Suk;Bae, Hyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.970-978
    • /
    • 2008
  • Objectives : This study aimed to clarify the relationship between the Oriental medical diagnosis and arteriosclerosis by measuring carotid-ankle vascular index(CAVI) in acute cerebral infarction patients. Method : One hundred thirty-one subjects were recruited from the patients admitted to the Internal Medical Department at Kyunghee University Oriental Medical Center from April 2007 to August 2008. We sorted cerebral infarction patients and assessed one hundred fourteen patients' CAVI data. We diagnosed dampness-phlegm by Oriental medical diagnosis and evaluated stroke type by single or multiple infarctions. then, we analyzed their characteristics with type of stroke, risk factor, lifestyle, metabolic syndrome and dampness-phlegm diagnosis. Result : 1. On the demographic variables of the patients, age, hypertension, hyperlipidemia, multiple infarction group and metabolic syndrome and dampness-phlegm group were significantly higher in the high CAVI score group than in the control. 2. According to the significant difference in the dampness-phlegm group, we analyzed dampness-phlegm related index for pattern identifications by CAVI score. As a result, dark circles, insomnia, headache, white coating tongue. slippery pulse, and rough pulse were significantly higher in the high CAVI score group then in the control. 3. In multivariate analysis, age, hypertension, multiple infarction and dampness-phlegm groups showed a close relationship with the high CAVI score group. Conclusions : According to the analysis, significance between dampness-phlegm diagnosed patients group and high CAVI score were clarified. Moreover, multiple location infarctions also have a relationship with high CAVI score in cerebral infarction patients. These results can be utilized in the future as a basis material.

  • PDF