• Title/Summary/Keyword: Pulse design

Search Result 1,442, Processing Time 0.031 seconds

The Basic Study on Design of Linear Pulse Motor for Embroidery Machine Characteristics (자수기 특성을 고려한 LPM의 설계에 관한 기초연구)

  • Park, Chang-Soon;Kwon, Tae-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.765-767
    • /
    • 2001
  • Linear pulse Motors(LPM) are widely used in fields where smooth linear motion is required, and their position accuracy is higher than other motors. Hybrid linear pulse motors(HLPM) are regarded as an excellent solution to positioning problems that require high accuracy, rapid acceleration and high-speed. The LPM has low mechanical complexity, high reliability, precise open-loop operation and low inertia etc. in many application areas such as factory automation speed positioning, computer peripherals and numerically controlled machine tools. This motor drive system is especially suitable for machine tools the high position accuracy and repeatability. This paper describes about that need of the embroider machine, we want to design position-scanning device for the embroidery machine. At first, to be analysed characteristics of the machine and next designed the LPM. we used the field analysis program, The finite element method(FEM) program tool is employed for calculation the force. The reluctance models will be used the magnetic permeance of air gap by static- conditions. The forces between forcer and platen have been calculated using the virtual work method.

  • PDF

A Development of the Optimized Shielding Room Design Simulator for HEMP Protection (HEMP 방호용 차폐실 최적설계를 위한 시뮬레이터 개발)

  • Min, Gyung-Chan;Kim, Dong-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2010
  • Regarding HEMP has been studied as few thousand of paper by major nuclear bomb holding countries with USA for the self protection against nuclear bomb attract. Major HEMP protection facilities are consist of the shielding, filtering, grounding and high voltage protection circuits. Shielding room construction required a highest cost among the key protective facilities. Most of a theoretical formulas listed on the paper and related books has a little correlations in the certain frequency band between the theoretical formulas and field measuring results. For the reasons we proposed the advanced new theoretical formulas and developed the computer simulation S/W as enough as apply to the cost effective shielding room design for HEMP considering the various structural constants.

The Effect of Aroma Inhalation Method on the Preoperative Anxiety of Abdominal Surgical Patients (향기흡입법이 복부수술 환자의 수술 전 불안 감소에 미치는 효과)

  • Choi, In-Sun;Lee, Myung-Sun;Ryoo, Eon-Na;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.2
    • /
    • pp.311-320
    • /
    • 2008
  • Purpose: The study was done to analyze the effects of aroma inhalation method on preoperative anxiety of abdominal surgical patients. Methods: The research design was a nonequivalent control group non-synchronized design. The data were collected from July 25 to October 21, 2005 at C Medical Center in Seoul. The patients were divided into two group of 24 subjects each. In order for measuring the all patient's anxiety before operation and aroma inhalation, Spidlberger(1975) trait anxiety, VAS(visual analogue scale) state anxiety, blood pressure, pulse rate were taken. After experimental group was taken aroma inhalation, VAS state anxiety, blood pressure, pulse rate were measured for two group. Results: After aroma inhalation, VAS state anxiety level, systolic blood pressure, diastolic blood pressure, pulse rate of the experimental group were decreased significantly than those of control group(p = .000, p = .000, p = .030. p = .000). Conclusion: The aroma inhalation method can be considered an effective nursing intervention that relieves the preoperative anxiety of abdominal surgical patients and stabilizes vital signs.

  • PDF

Design of a Single Pulse Laser Range Finder with Er:Yb:glass Microchip Lasers (어븀:이터븀:유리 마이크로칩 레이저를 이용한 단펄스 거리측정기 설계)

  • Koh, Hae Seog;Lee, Chang Jae;Park, Choong Bum;Jeon, Hyoung Ha;Ahn, Pil Dong;Park, Do Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.295-305
    • /
    • 2018
  • We present a passively Q-switched monolithic Er:Yb:glass microchip laser developed in our lab. The microchip laser can produce pulses at 1535 nm of the 'eye-safe' wavelengths with the pulse energy of 50 uJ and the pulse width of 4-6 ns. Using the laser we also designed and developed a pulsed Er:Yb:glass microchip laser rangefinder. Expressions for background and signal power, noise, and signal-to-noise ratio are reviewed. A computer simulation was used to optimize laser power, receiver aperture, and preamplifier bandwidth for the efficient system design of the laser rangefinder. Experimental results are presented to compare with the theory.

Effects of Distraction using Operating Doll on Preschool Children's Pain during an IV Catheter Insertion (작동인형을 이용한 관심전환이 정맥주사 시 학령전기 아동의 통증에 미치는 효과)

  • Lee Boon-Sim;Kwon In-Soo
    • Child Health Nursing Research
    • /
    • v.11 no.4
    • /
    • pp.490-497
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate the effect on pain of distraction with an operating doll in preschool children(3-6 years old) during an IV catheter insertion. Method: The research design was a nonequivalent control group posttest design, and the participants were 22 children in the experimental group, and 23 children in the control group. The children were hospitalized for enteritis and pharyngitis in a university hospital. The subjective pain was measured using FACES Pain Rating Scale by self report, and the pain behavior responses were scored using Procedure Behavior Check List by observing a film of the entire procedure, and changes in pulse and oxygen saturation as the physiological pain responses were measured by pulse oximeter. Data were analyzed with the SPSS Win 10.0 program. Result: The degree of subjective pain, pain behavior responses, and changes in pulse during IV catheter insertion were significantly lower in the experimental group. But there was no significant difference in $O_2$ saturation between the two groups. Conclusion: Distraction using an operating doll was effective in decreasing pain during inserting the IV catheter in preschool children.

  • PDF

Effect of Foot Reflex Massage on Stress Responses, and Glucose Level of Non-Insulin Dependent Diabetes Mellitus Patients (발반사 마사지가 인슐린 비의존성 당뇨병 환자의 스트레스반응과 혈당에 미치는 효과)

  • Kim, Keum-Soon
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.6 no.2
    • /
    • pp.152-163
    • /
    • 2003
  • Purpose; This study was done to investigate the effect of foot reflexology on vital signs, general fatigue, foot fatigue, mood, and blood glucose levels in noninsulin dependent patients. Method: The Research design of this study was nonequivalent control group quasi-experimental design. 18 patients were assigned to the experimental group, 24 patients to the control group. The data were obtained diaberic patients with ambulatory endocrine outpatients clinic patients from 40 years old to 70 years old. Experimental groups received foot reflex massage for 30minutes three times/week every other days, and Control groups did not received foot reflex massage. The dependent variables were blood pressure, pulse rate, visual analogue scale for general fatigue, foot fatigue, mood, and blood sugar levels. Data were analyzed with $X^2$ test, t-test and repeated measure ANOVA at .0.05 level of significance. Results: There were significant difference in the pulse rate, general fatigue, foot fatigue and mood according to group and time between pre and post foot reflexology. But this research did not prove to decrease blood sugar levels. Conclusions : Foot reflexology can imorove pulse rate, general and foot fatigue, and mood status in diabetus patients. So further research need to explore the effect of decreasing of blood sugar levels.

  • PDF

The Study on Design and Dynamic Operation Characteristics of Linear Pulse I for Embroidery Machine (자수기에 맞는 LPM의 설계와 구동 특성에 관한 연구)

  • Park, Chang-Soon;Kwon, Tae-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.91-93
    • /
    • 2001
  • Linear pulse Motors(LPM) are widely used in fields where smooth linear motion is required, and their position accuracy is higher than other motors. Hybrid linear pulse motors(HLPM) are regarded as an excellent solution to positioning problems that require high accuracy, rapid acceleration and high-speed. The LPM has low mechanical complexity, high reliability, precise open-loop operation and low inertia etc. In many application areas such as factory automation speed positioning, computer peripherals and numerically controlled machine tools, LPM can be used. This motor drive system is especially suitable for machine tools the high position accuracy and repeatability. This paper describes about that need of the embroider machine, we want to design position-scanning device for the embroidery machine. At first, to be analysed characteristics of the machine and next designed the LPM, we used the field analysis program. The finite element method(FEM) program tool is employed for calculation the force. The reluctance models will be used the magnetic permeance of air gap by static-conditions. The forces between forcer and platen have been calculated using the virtual work method. And we used the simulink to know the dynamic characteristics of LPM.

  • PDF

Design of STM32-based Quadrotor UAV Control System

  • Haocong, Cai;Zhigang, Wu;Min, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.2
    • /
    • pp.353-368
    • /
    • 2023
  • The four wing unmanned aerial vehicle owns the characteristics of small size, light weight, convenient operation and well stability. But it is easily disturbed by external environmental factors during flight with these disadvantages of short endurance and poor attitude solving ability. For solving these problems, a microprocessor based on STM32 chip is designed and the overall development is completed by the resources such as built-in timer and multi-function mode general-purpose input/output provided by the master micro controller unit, together with radio receiver, attitude meter, barometer, electronic speed control and other devices. The unmanned aerial vehicle can be remotely controlled and send radio waves to its corresponding receiver, control the analog level change of its corresponding channel pins. The master control chip can analyze and process the data to send multiple sets pulse signals of pulse width modulation to each electronic speed control. Then the electronic speed control will transform different pulse signals into different sizes of current value to drive the motor located in each direction of the frame to generate different rotational speed and generate lift force. To control the body of the unmanned aerial vehicle, so as to achieve the operator's requirements for attitude control, the PID controller based on Kalman filter is used to achieve quick response time and control accuracy. Test results show that the design is feasible.

Control System Design for Self-Commutated Static Var Compensator (전압원인버터방식 송전용 무효전력보상기의 제어시스템 설계)

  • 한병문
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.89-92
    • /
    • 1996
  • This paper describes a detailed simulation model of the static condenser (STATCON) to analyze the dynamic interaction with the ac transmission line. The static condenser was represented by a 12-pulse voltage-source inverter sharing an energy storage dc capacitor. The voltage-source inverter consists of two 6-pulse bridges modeled with ideal gate-turn-off switches. The control system for the static condenser was designed through a mathematical model deduced from the equivalent circuit. Simulation results show that the conceived model is very effective to analyze the dynamic interaction between the static condenser and the ac transmission system.

  • PDF

A novel resonant pulse control in resonant DC link inverter (공진형 직류 링크 인버터의 공진 펄스 제어기)

  • 유동욱;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF