• Title/Summary/Keyword: Pulse design

Search Result 1,439, Processing Time 0.026 seconds

Design of Current Controller for Performance Improvement of Linear Pulse Motor Using Neural Networks (리니어펄스모터의 제어 성능 향상을 위한 신경 회로망을 이용한 전류 제어기 설계)

  • Park, Jong-Bum;Park, Jung-Il;Lee, Suk-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.486-489
    • /
    • 1998
  • In this paper, we introduced the neural network to reduce force ripple of current controller for a linear pulse motor. In general, conventional position controllers of linear pulse motor disregard the modeling error and load variations, which cause inaccuracy in position control. The proposed current controller based on neural network teaming modifies the current commands in order to reduce force ripple due to these factors. The experiment results show that the proposed controller works efficiently for accurate position control of linear pulse motor.

  • PDF

Marx Generator Implementation Using IGBT Stack (IGBT 스택을 이용한 Marx Generator 구현)

  • Kim, J.H.;Min, B.D.;Kim, J.S.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.507-510
    • /
    • 2005
  • High voltage pulse power supply using Marx generator and solid-state switches is proposed in this study. The Marx generator is composed of 12 stages and each stage is made of IGBT stack, two diode stacks, and capacitor. To charge the capacitors of each stage in parallel, inductive charging method is used and this method results in high efficiency and high repetition rates. It can generate the pulse voltage with the following parameters: Voltage: up to 120kv Rising time: sub ${\mu}S$ Pulse width: up to $10{\mu}S$, Pulse repetition rate: 1000pps The proposed pulsed power generator uses IGBT stack with a simple driver and has modular design. So this system structure gives compactness and easiness to implement total system. Some experimental results are included to verify the system performances in this paper.

  • PDF

Study on the Technical Trend of a Pulse Separation Device with Thermal Barrier Type (격막형 펄스분리장치 기술동향 연구)

  • Kim, Won-Hoon;Lee, Bang-Eop;Koo, Song-Hoe;Lee, Won-Bok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.225-228
    • /
    • 2010
  • In this paper, the present status of research, development, and required technologies for the thermal barrier type dual-pulse rocket motor of the advanced countries was analysed. The result of the conceptual design of the forward or backward ignition systems was also demonstrated.

  • PDF

Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation

  • Chen, Keng-Yuan;Hu, Jwu-Sheng;Lin, Jau-Nan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.388-397
    • /
    • 2016
  • An error-compensated pulse width modulator (ECPWM) is proposed to improve the baseband harmonic performance and the switching loss of voltage source inverters (VSIs). Selecting between harmonic distortion and switching loss is a design tradeoff in the conventional space vector pulse width modulation. In this work, an accumulated difference in produced and desired phase voltages is considered to adjust the reference signal. This mechanism can compensate for the voltage error in the previous carrier period. With error compensation every half-carrier period, the proposed ECPWM allows one-half reduction in carrier frequency without scarifying baseband harmonic distortion. The proposed modulator is applied to a three-phase VSI with R-L load and a motor-speed-control system for experiments. The measured efficiency and operating temperature of switches confirm the effectiveness of the proposed scheme.

Synchronous Visible Light Communication Systems Using 3-Level LED Modulation (3-Level LED 변조를 이용한 동기식 가시광통신 시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.421-427
    • /
    • 2013
  • In this paper, we introduce a new synchronous visible light communication system in which the synchronizing pulse and the data bits are simultaneously transmitted using a 3-level light signal. In the transmitter, the synchronizing pulse and the data bits modulate independently two identical visible LEDs, whose output lights add in free space, make 3-level optical signal. In the receiver, a photodiode detects the light and generates a 3-level output voltage, whose positive and negative part correspond to the synchronizing pulse and the data bits, respectively. The two signals are easily separated and recovered by a simple diode circuit. This configuration provides two independent VLC channels without any multiplexing technique, simplifies the circuit design and construction of synchronous VLC systems.

An Effect of Qi Gong Gymnastics Program on the Physiopsychological Parameter in Essential Hypertension (기공체조프로그램이 고혈압 환자의 생리.심리적 지수에 미치는 영향)

  • 이명숙;최의순
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.4
    • /
    • pp.856-868
    • /
    • 1998
  • The purpose of this study is to evaluate the effects of Qigong gymnastics exercise program on the physiopsychological parameter in essential hypertension. The design of the research was a one group pretest-posttest design. A total of 20 pateints with hypertension who were from forty to sixty-five years old participated in the study. The Qigong gymnastics program was carried out twice a week for thirty minutes or forty minutes for six weeks from 22, Sep. to 31, Oct. in 1997. In order to evaluate the effect of the Qigong gymnastics program physiological parameter (blood pressure, pulse rate, FVC, FEV1, Epinephrine, Norepinephrine, Cortisol) and psychological parameter(self-efficacy, Life satisfaction) were measured before and after the exercise program. Collected data was analyzed by the paired t-test with SAS package. The result are as follows : 1) There were significant decrease in systolic blood pressure and diastolic blood pressure, but there was no significant change in pulse rate. 2) There were no significant difference in FVC and FEV1 3) There were significant decrease in epinephrine, norepinephrine and cortisol. 4) There were significant improved in general self-efficacy and life satisfaction. 5) The effect of Qigong gymnastics program by measurement time on blood pressure and pulse rate were as follows : In a systolic blood pressure was gradually significant decreased from 1 week to 6 weeks and diastolic blood pressure was significantly decreased after 4weeks. But there was no significant change in pulse rate. This results suggest that Qigong gymnastics are an appropriate nursing intervention for clients with hypertension. For further research is necessary to reevaluate the effect with a letter experimental design and longer period than 8 weeks for the Qigong gymnastics program.

  • PDF

A Design for Solid-State Radar SSPA with Sequential Bias Circuits (순차바이어스를 이용한 반도체 레이더용 SSPA 설계)

  • Koo, Ryung-Seo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2479-2485
    • /
    • 2013
  • In this paper, we present a design for solid-state radar SSPA with sequential bias. We apply to variable extension pulse generator to eliminate signal distortion which is caused by bias rising/falling delay of power amplifier. There is an optimum impedance matching circuit to have high efficiency of GaN-power device by measuring microwave characteristics through load-pull method. The designed SSPA is consisted of pre-amplifier, drive-amplifier and main-amplifier as a three stages to apply for X-Band solid-state radar. Thereby we made a 200W SSPA which has output pulse maximum power shows 53.67dBm and its average power is 52.85dBm. The optimum design of transceiver module for solid-state pulse compression radar which is presented in this dissertation, it can be available to miniaturize and to improve the radar performances through additional research for digital radar from now on.

Design and Operation Characteristics of 2.4MJ Pulse Power System for Electrothermal-Chemical(ETC) Propulsion(I) (전열화학추진용 2.4MJ 펄스파워전원의 설계와 동작특성(I))

  • Jin, Y.S.;Lee, H.S.;Kim, J.S.;Cho, J.H.;Lim, G.H.;Kim, J.S.;Chu, J.H.;Jung, J.W.;Hwang, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1868-1870
    • /
    • 2000
  • As a drive for an ETC (Electro-thermal Chemical) launcher, a large pulse power system of a 2.4MJ energy storage was designed, constructed and tested. The overall power system consists of eight capacitive 300kJ energy storage banks. In this paper we describe the design features, setup and operation test result of the 300kJ pulsed power module. Each capacitor bank of the 300kJ module consists of six 22kV 50kJ capacitors. A triggered vacuum switch (TVS-43) was adopted as the main pulse switch. Crowbar diode circuits, variable multi-tap inductors and energy dumping systems are connected to each high power capacitor bank via bus-bars and coaxial cables. A parallel crowbar diode stack is fabricated in coaxial structure with two series 13.5kV, 60kA avalanche diodes. The main design parameters of the 300kJ module are a maximum current of 180kA and a pulse width of 0.5 - 3ms. The electrical performances of each component and current output variations into resistive loads have been investigated.

  • PDF

Design and embodiment about pulse modeling of light investigation for disease treatment by skin color (피부색에 따른 병변치료를 위한 광조사펄스모델링에 대한 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.5
    • /
    • pp.563-572
    • /
    • 2006
  • Advantage that light transmission treatment way of most suitable through skin can investigate light directly in part ar there is difference in ability photoelectricity month by diverse complexion of horn character department which is branch or head of a family outside part of skin and treatment according to various patient can be inappropriate. By result that this research uses color information after search each color ingredient that ingredient of HIS and YIQ that use method, color information to use skin impedance way and color information through skin area ion and difference video to do fixed measuring by light investigation way by skin impedance corresponds to skin color in an experiment though is most universal result according to patient's skin model area detection each single person's skin model through videotex automatically create and because measuring, investigate skin color, energy, wave length, approximately, transmission time, model of most suitable that draw pulse delay and so on and want and special quality, and saved standard of disease treatment pulse modeling by skin impedance, and design and manufacture light investigation pulse modeling system of most suitable by skin subordinate, and constructed suitable treatment pulse database by skin color.

  • PDF

Development of 3 D.O.F parallel robot's simulator for education

  • Yoo, Jae-Myung;Kim, John-Hyeong;Park, Dong-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2290-2295
    • /
    • 2005
  • In this paper, it is developed simulator system of 3 D.O.F parallel robot for educate of expertness. This simulator system is composed of three parts ? 3 D.O.F parallel robot, controller (hardware) and software. First, basic structure of the robot is 3 active rotary actuator that small geared step motor with fixed base. An input-link is connected to this actuator, and this input-link can connect two ball joints. Thus, two couplers can be connected to the input-link as a pair. An end-plate, which is jointed by a ball joint, can be connected to the opposite side of the coupler. A sub-link is produced and installed to the internal spring, and then this sub-link is connected to the upper and bottom side of the coupler in order to prevent a certain bending or deformation of the two couplers. The robot has the maximum diameter of 230 mm, 10 kg of weight (include the table), and maximum height of 300 mm. Hardware for control of the robot is composed of computer, micro controller, pulse generator, and motor driver. The PC used in the controller sends commands to the controller, and transform signals input by the user to the coordinate value of the robot by substituting it into equations of kinematics and inverse kinematics. A controller transfer the coordinate value calculated in the PC to a pulse generator by transforming it into signals. A pulse generator analyzes commands, which include the information received from the micro controller. A motor driver transfer the pulse received from the pulse generator to a step motor, and protects against the over-load of the motor Finally, software is a learning purposed control program, which presents the principle of a robot operation and actual implementation. The benefit of this program is that easy for a novice to use. Developed robot simulator system can be practically applied to understand the principle of parallel mechanism, motors, sensor, and various other parts.

  • PDF