• Title/Summary/Keyword: Pulse design

Search Result 1,446, Processing Time 0.026 seconds

Controlled Surface Functionalities of metals using Femtosecond Laser-induced Nano- and Micro-scale Surface Structures (펨토초 레이저 유도 나노 및 마이크로 구조물을 활용한 금속 표면 기능성 제어)

  • Taehoon Park;Hyo Soo Lee;Hai Joong Lee;Taek Yong Hwang
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.55-61
    • /
    • 2023
  • With femtosecond (fs) laser pulse irradiation on metals, various types of nano- and micro-scale structures can be naturally induced at the surface through laser-matter interaction. Two notable structures are laser-induced periodic surface structures (LIPSSs) and cone/spike structures, which are known to significantly modify the optical and physical properties of metal surfaces. In this work, we irradiate fs laser pulses onto various types of metals, cold-rolled steel, pickled & oiled steel, Fe-18Cr-8Ni alloy, Zn-Mg-Al alloy coated steel, and pure Cu which can be useful for precise molding and imprinting processes, and adjust the morphological profiles of LIPSSs and cone/spike structures for clear structural coloration and a larger range of surface wettability control, respectively, by changing the fluence of laser and the speed of raster scan. The periods of LIPSSs on metals used in our experiments are nearly independent of laser fluence. Accordingly, the structural coloration of the surface with LIPSSs can be optimized with the morphological profile of LIPSSs, controlled only by the speed of the raster scan once the laser fluence is determined for each metal sample. However, different from LIPSSs, we demonstrate that the morphological profiles of the cone/spike structures, including their size, shape, and density, can be manipulated with both the laser fluence and the raster scan speed to increase a change in the contact angle. By injection molding and imprinting processes, it is expected that fs laser-induced surface structures on metals can be replicated to the plastic surfaces and potentially beneficial to control the optical and wetting properties of the surface of injection molded and imprinted products.

Design of power and phase feedback control system for ion cyclotron resonance heating in the Experimental Advanced Superconducting Tokamak

  • L.N. Liu;W.M. Zheng;X.J. Zhang;H. Yang;S. Yuan;Y.Z. Mao;W. Zhang;G.H. Zhu;L. Wang;C.M. Qin;Y.P. Zhao;Y. Cheng;K. Zhang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.216-221
    • /
    • 2024
  • Ion cyclotron range of frequency (ICRF) heating system is an important auxiliary heating method in the experimental Advanced Superconducting Tokamak (EAST). In EAST, several megawatts of power are transmitted with coaxial transmission lines and coupled to the plasma. For the long pulse and high power operation of the ICRF waves heating system, it is very important to effectively control the power and initial phase of the ICRF signals. In this paper, a power and phase feedback control system is described based on field programmable gate array (FPGA) devices, which can realize complicated algorithms with the advantages of fast running and high reliability. The transmitted power and antenna phase are measured by a power and phase detector and digitized. The power and phase feedback control algorithms is designed to achieve the target power and antenna phase. The power feedback control system was tested on a dummy load and during plasma experiments. Test results confirm that the feedback control system can precisely control ICRF power and antenna phase and is robust during plasma variations.

Performance Analysis of Spiral Axicon Wavefront Coding Imaging System for Laser Protection

  • Haoqi Luo;Yangliang Li;Junyu Zhang;Hao Zhang;Yunlong Wu;Qing Ye
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.355-365
    • /
    • 2024
  • Wavefront coding (WFC) imaging systems can redistribute the energy of an interference laser spot on an image plane sensor by wavefront phase modulation and reduce the peak intensity, realizing laser protection while maintaining imaging functionality by leveraging algorithmic post-processing. In this paper, a spiral axicon WFC imaging system is proposed, and the performance for laser protection is investigated by constructing a laser transmission model. An Airy disk on an image plane sensor is refactored into a symmetrical hollow ring by a spiral axicon phase mask, and the maximum intensity can be reduced to lower than 1% and single-pixel power to 1.2%. The spiral axicon phase mask exhibits strong robustness to the position of the interference laser source and can effectively reduce the risk of sensor damage for an almost arbitrary lase propagation distance. Moreover, we revealed that there is a sensor hazard distance for both conventional and WFC imaging systems where the maximum single-pixel power reaches a peak value under irradiation of a power-fixed laser source. Our findings can offer guidance for the anti-laser reinforcement design of photoelectric imaging systems, thereby enhancing the adaptability of imaging systems in a complex laser environment. The laser blinding-resistant imaging system has potential applications in security monitoring, autonomous driving, and intense-laser-pulse experiments.

Analysis of Parasitic Inductance and Switching Losses through Lead Frame Modification and Snubber for Automotive SiC Power Modules (리드프레임 구조 변형 및 스너버 회로를 통한 자동차용 SiC 파워모듈의 기생인덕턴스 감소와 스위칭 손실 분석)

  • Jaejin Jeon;Seokjin Shin;Kyung Tae Min;Sang Won Yoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.3
    • /
    • pp.99-104
    • /
    • 2024
  • With the advancement of power electronics technology and the increasing demand for high-efficiency power semiconductors, silicon carbide (SiC) devices have gained attention as an alternative to overcome the limitations of traditional silicon (Si) semiconductors. SiC devices enable excellent switching efficiency due to their high switching speed. However, parasitic inductance within the power module can cause voltage oscillations and overshoot phenomena, potentially leading to issues with electrical reliability and efficiency. To address these challenges, two approaches were proposed and validated. The first approach involved applying an RC snubber circuit to mitigate the effects of parasitic inductance, thereby improving electrical stability. The second approach focused on optimizing the lead-frame design to reduce parasitic inductance. Both methods were verified through simulations and experiments, demonstrating that the electrical reliability and efficiency of SiC power modules can be simultaneously improved.

ETS Sampler design for borehole radar receiver using 4 different clock phases (위상이 다른 4개의 클럭을 이용한 시추공 레이다 수신기용 ETS 샘플러 설계)

  • Yoo, Young-jae;Oh, Chaegon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.680-687
    • /
    • 2018
  • Borehole radar is a radar used for underground resources and geological exploration purposes. It needs a high-speed sampler to transmit electromagnetic waves with a pulse width of several ns and to receive reflected waves of several tens to several hundreds of MHz reflected from the object to be surveyed. ETS (Equivalent-Time Sampling), which can achieve sampling performance of several GHz with a sampling frequency of several tens of MHz, is suitable for use as a sampler of a borehole radar receiver. In this paper, we propose a method to control the sampling clock delay, which is the most important factor in ETS sampler design, using four clocks with phase difference of $90^{\circ}$ for one clock source. The proposed method can reduce the time required to acquire the data within the set interval by 1/25 than the conventional method using the delay generator. When the implemented sampler is applied to the receiver of existing borehole radar, it is possible to accumulate 58 additional times due to the shortened sampling time. In addition, by using one delay control logic compared with the conventional method using several sampling clock delay control logic in order to satisfy the target sampling range, it is possible to omit the correction process which was necessary in the past. As a result, the structure of the system can be simplified and a uniform sampler can be realized.

A Design of LLC Resonant Controller IC in 0.35 um 2P3M BCD Process (0.35 um 2P3M BCD 공정을 이용한 LLC 공진 제어 IC 설계)

  • Cho, Hoo-Hyun;Hong, Seong-Wha;Han, Dae-Hoon;Cheon, Jeong-In;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.71-79
    • /
    • 2010
  • This paper presents a design of a LLC resonant controller IC. LLC resonant controller IC controls the voltage of the 2nd side by adjusting frequency the input frequency of the external resonant circuit. The clock generator is integrated to provide the pulse to the resonant circuit and its frequency is controlled by the external resistor. Also, the frequency of the VCO is adjusted by the feedback voltage. The protection circuits such as UVLO(Under Voltage Lock Out), brown out, fault detector are implemented for the reliable and stable operation. The HVG, and LVG drivers can provide the high current and voltage to the IGBT. The designed LLC resonant controller IC is fabricated with the 0.35 um 2P3M BCD process. The overall die size is $1400um{\times}1450um$, and supply voltage is 5V, 15V.

Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture (사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan;Jin, Hyeong-Seok;Park, Jong-Sul;Jang, Ho-Ki;Kim, Bo-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1034-1046
    • /
    • 2011
  • In this paper, a design and fabrication of 40 W power amplifier for the X-band using load-pull measurement of GaN HEMT chip are presented. The adopted active device for power amplifier is GaN HEMT chip of TriQuint company, which is recently released. Pre-matched fixtures are designed in test jig, because the impedance range of load-pull tuner is limited at measuring frequency. Essentially required 2-port S-parameters of the fixtures for extraction optimal input and output impedances is obtained by the presented newly method. The method is verified in comparison of the extracted optimal impedances with data sheet. The impedance matching circuit for power amplifier is designed based on EM co-simulation using the optimal impedances. The fabricated power amplifier with 15${\times}$17.8 $mm^2$ shows the efficiency above 35 %, the power gain of 8.7~8.3 dB and the output power of 46.7~46.3 dBm at 9~9.5 GHz with pulsed-driving width of 10 usec and duty of 10 %.

The Design of 32 Bit Microprocessor for Sequence Control Using FPGA (FPGA를 이용한 시퀀스 제어용 32비트 마이크로프로세서 설계)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.431-441
    • /
    • 2003
  • This paper presents the design of 32 bit microprocessor for a sequence control using a field programmable gate array(FPGA). The microprocessor was designed by a VHDL with top down method, the program memory was separated from the data memory for high speed execution of sequence instructions. Therefore it was possible that sequence instructions could be operated at the same time during the instruction fetch cycle. In order to reduce the instruction decoding time and the interface time of the data memory interface, an instruction code size was implemented by 32 bits. And the real time debug operation was implemented for easeful debugging the designed processor with a single step run, PC break point run, data memory break point run. Also in this designed microprocessor, pulse instructions, step controllers, master controllers, BM and BCD type arithmetic instructions, barrel shift instructions were implemented for sequence logic control. The FPGA was synthesized under a Xilinx's Foundation 4.2i Project Manager using a V600EHQ240 which contains 600,000 gates. Finally simulation and experiment were successfully performed respectively. For showing good performance, the designed microprocessor for the sequence logic control was compared with the H8S/2148 microprocessor which contained many bit instructions for sequence logic control. The designed processor for the sequence logic showed good performance.

System Design and Performance Analysis of a Variable Frequency LED Light System for Plant Factory

  • Han, Jae Woong;Kang, Tae Hwan;Lee, Seong Ki;Han, Chung Su;Kim, Woong
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.87-95
    • /
    • 2014
  • Purpose: The purpose of this study was to design a variable frequency LED light system for plant factory which combined red, blue, green, white, and UV lights and controlled the ratio of the light wavelength. In addition, this study evaluated the performance of each combination of LED to verify the applicability. Methods: Four combinations of LED (i.e. Red+Blue, Red+Blue+Green, Red+Blue+White, Red+Blue+UV) were designed using five types of LED. The system was designed to control the duty ratio of each wavelength of LED by 1% interval from 0~100%, the pulse by 1Hz interval from 1~20kHz. Response characteristics of the control system, spectral distribution of each combination, light uniformity and uniformity ratio were measured to test the performance of the system. Results: Clean waveforms were measured from 10Hz to 10kHz regardless of duty ratio. Frequency distortion was observed within 5% of inflection point at frequencies above 10kHz regardless of duty ratio, but it was judged negligible. Spectra showed a normal distribution, and maximum PPF with duty ratio of 100% was $271.4{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for the Red+Blue combination. PPF of the Red+Blue+Green combination was $258.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and that of the Red+Blue+White combination was $273.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. PPF of the Red+Blue+UV combination was $267.7{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Uniformity ratio for the area excepting border showed 0.90 for the Red+Blue and Red+Blue+White combinations, 0.87 for the Red+Blue+Green combination, and 0.88 for the Red+Blue+UV combination. The light was irradiated evenly at the area excepting border, so it was suitable for plant growing. Conclusions: From the results of this study, response characteristics of the control system, spectral distribution of each combination, light uniformity and uniformity ratio were suitable for applying into the plant factory.

The Comparison of Effectiveness in Prehospital Protocol Education on CardioPulmonary Resuscitation (심폐소생술에 대한 현장업무 프로토콜 교육 효과 비교)

  • Shin, Sang-Yol;Jung, Ji-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3418-3426
    • /
    • 2009
  • The purpose of this study was to investigate the feasibility of field operation protocol for cardiopulmonary resuscitation(CPR) in person with non-traumatic arrest. This study was performed from May 1 through June 27, 2008, and subjects were 150 students who are attending the department of Emergency Medical Service in J and K universities which located in Jeollabuk-do and Jeollanam-do areas. Practical conformance was verified using by nonequivalent control group pretest-posttest design. This study divided into two groups; experimental group that employed field operation protocol and control group that applied conventional CPR protocol, and comparative analyzed statistically the necessary time of the items of each protocol. The results indicated that each performance time of 18 items was reduced over 3 seconds except 5 items(assessment of consciousness, airway control, two times of artificial respiration, check of circulation, and five cycles of CPR). And time of 6 items(intubation, peripheral intravenous line, reassessment of consciousness, pupil reaction, carotid artery pulse, and vital sign) was minimized more than 60 seconds, and total performing time was shortened 110.85 seconds. The results suggested that total performing time in pre and post test where the protocol was applied for two groups showed a statistically significant decrease(t=-6.580, p=.000). Consequently, field operation protocol for cardiopulmonary resuscitation(CPR) in person with non-traumatic arrest will be a available manual which support prompt and accurate decision making, and improve emergency medical service.