• Title/Summary/Keyword: Pulse amplitude

Search Result 495, Processing Time 0.027 seconds

Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator (스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

Response Characteristic Analysis of ZnO Varistors by the Conductive E1 Pulse (전도성 E1 펄스에 대한 ZnO 바리스터의 동작특성 분석)

  • Bang, Jeong-Ju;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.241-245
    • /
    • 2019
  • This work presents the response characteristics of a ZnO varistor to conductive EMP. An E1 pulse, standardized to MIL-STD-188-125-1, was applied to the varistors wherein the residual current and response times were measured with the applied E1 pulse current. Additionally, the response time was measured according to the length of the connection path. Consequently, the amplitude of the residual voltage through the ZnO varistors was increased with increasing amplitude of the applied E1 pulse current. As the length of the connection path increased, the operating response time and residual peak voltage also increased. These results indicate that the response characteristics of ZnO varistors can be applied to basic data to support the use of varistors as a protective measure against conductive EMP.

An ACLMS-MPC Coding Method Integrated with ACFBD-MPC and LMS-MPC at 8kbps bit rate. (8kbps 비트율을 갖는 ACFBD-MPC와 LMS-MPC를 통합한 ACLMS-MPC 부호화 방식)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • This paper present an 8kbps ACLMS-MPC(Amplitude Compensation and Least Mean Square - Multi Pulse Coding) coding method integrated with ACFBD-MPC(Amplitude Compensation Frequency Band Division - Multi Pulse Coding) and LMS-MPC(Least Mean Square - Multi Pulse Coding) used V/UV/S(Voiced / Unvoiced / Silence) switching, compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. In integrating several methods, it is important to adjust the bit rate of voiced and unvoiced sound source to 8kbps while reducing the distortion of the speech waveform. In adjusting the bit rate of voiced and unvoiced sound source to 8 kbps, the speech waveform can be synthesized efficiently by restoring the individual pitch intervals using multi pulse in the representative interval. I was implemented that the ACLMS-MPC method and evaluate the SNR of APC-LMS in coding condition in 8kbps. As a result, SNR of ACLMS-MPC was 15.0dB for female voice and 14.3dB for male voice respectively. Therefore, I found that ACLMS-MPC was improved by 0.3dB~1.8dB for male voice and 0.3dB~1.6dB for female voice compared to existing MPC, ACFBD-MPC and LMS-MPC. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or internet phone. In the future, I will study the evaluation of the sound quality of 6.9kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source.

Inactivation of N-Type Calcium Current in Rat Sympathetic Neurons

  • Goo, Yong-Sook;Keith S. Elmslie
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1999.06a
    • /
    • pp.52-52
    • /
    • 1999
  • Inactivation of N-type calcium current has been reported to be voltage dependent (Jones & Marks, 1989) and $Ca^{2+}$ dependent(Cox & Dunlap, 1994). We examined inactivation by recording currents from the same cell both in [B $a^{2+}$]$_{o}$ and [C $a^{2+}$]$_{o}$ in rat sympathetic neurons. With 11 mM internal EGTA, fractional inactivation[l-(current amplitude at the end of 5 sec pulse/peak current amplitude [1-(current amplitude at the end of 5 sec pulse/peak current amplitude)] was larger in $Ca^{2+}$(0.80$\pm$0.07) than in $Ba^{2+}$(0.69$\pm$0.10)(n=31, p<0.001), but the current traces were nicely fitted with two exponential components both in $Ba^{2+}$ and $Ca^{2+}$.(omitted)ted)ted)

  • PDF

Analysis and Applications of Multi-user DS-PAM and TH-PPM UWB System (다중 사용자 환경에서의 DS-PAM과 TH-PPM UWB 시스템의 분석과 응용)

  • Sung, Tae-Kyung;Kim, Dong-Seek;Kim, Cheol-Seong;Cho, Hyung-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.603-610
    • /
    • 2008
  • In this paper, analytical methods for calculating the average probability of bit error of direct sequence pulse amplitude modulation ultra wideband (DS-PAM UWB) system and time hopping pulse position modulation ultra wideband (TH-PPM UWB) system are given. For the multi-user DS-PAM UWB system, the bipolar pulse amplitude modulation is used in order to achieve better performance. As we know, more attention is paid to the TH-PPM UWB systems recently. In this paper. we first introduce the accurate BER calculation methods of the multi-user DS-PAM UWB and TH-PPM UWB systems and then give the performance analysis over the ideal AWGN channel and a correlation receiver. Furthermore, we also introduce their applications in image transmission and data transmission and give the simulation results. The analytical method yields simple and exact formulas relating the performance to the system parameters.

Performance Analysis of Ultra Wide Band Systems in Indoor Wireless Channel (실내 무선 채널에서 초광대역 무선통신 시스템의 성능 분석)

  • Kim, Eun-Cheol;Woo, Sang-Kyu;Yang, Jae-Soo;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.39-42
    • /
    • 2008
  • In this paper, we analyze the performance of ultra wide band (UWB) systems in indoor wireless channel in accordance with the number of pulses per bit at transmit signals and the decision types of receiver. The indoor channel is modeled as the modified Saleh and Valenzuela (SV) model which has been proposed as a UWB channel model by the IEEE group, IEEE 802.15.SG3a. Two types of UWB signals are considered One is the pulse position modulation-time hopping (PPM-TH) signal. And the other is the pulse amplitude modulation-direct sequence (PAM-DS) signal. It is assumed that the receiver is an ideal receiver which can receive all signals of the multipath.

  • PDF

Performance Analysis of TH-BPPM and TH-BPAM UWB System and the Applications in Data and Image Transmission

  • Sung, Tae-Kyung
    • Journal of Navigation and Port Research
    • /
    • v.31 no.2
    • /
    • pp.159-163
    • /
    • 2007
  • In this paper, we mainly analyze the performance of two ultra wideband communication systems, the classical Time Hopping Binary Pulse Position Modulation (TH-BPPM) UWB system and the Time Hopping Bipolar Pulse Amplitude Modulation (TH-BPAM) UWB system. The performance of TH-BPPM and TH-BPAM is analyzed in detail under an ideal AWGN channel and a correlation receiver. We use the power spectral density function to get the expression of BER of these two UWB systems. It yields simple and exact formulas relating the performance to the system parameters. The analysis shows that TH-BPPM suffers performance degradation with respect to TH-BPAM. Furthermore, we give the computer simulation of both data and image transmission and our simulation results also prove our theoretical analysis.

Digital Control of Single Phase Buck-Boost Converter by Pulse Amplitude Modulation Mehtod (PAM방식을 적용한 단상 승강압형 정류기의 디지탈제어)

  • 김태진;변영복;조기연;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.54-57
    • /
    • 1998
  • This paper describes a digital implementation of a pulse amplitude modulation(PAM) method for a unity-power-factor buck-booster converter. A digital controller is designed and implemented by a Digital Signal Processor(DSP) to replace the analog control circuit for PAM. Experimental results are presented and compared with simulations.

  • PDF

Metal Drilling using Amplitude Modulated Laser Pulse (AM 변조된 레이저 펄스를 이용한 금속 Drilling)

  • Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1210-1212
    • /
    • 1994
  • An amplitude modulation technique for increasing the laser penetration efficiency for metals has been studied. By chopping electro-optically Nd:YAG laser pulse, the threshold energy for reliable hole drilling was decreased significantly and the penetration depth was increased. It was observed that the effect of chopping was optimal at 8-12 kHz with 60% duty cycle. It is believed that this improvement is due to an increase in the vapor recoil pressure and reduced plasma screening.

  • PDF

The Effects of Sa-Am Acupuncture on the Radial Pulse in Healthy Human Subjects: A Comparative Study of Pericardium jung-gyuck and Triple Energizer jung-gyuck

  • Kim, Tae-Min;Kim, Jea-Hong;Lee, Hyun-Suk;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.41-54
    • /
    • 2017
  • Objectives: The purpose of this study is to investigate the effects of Sa-am acupuncture with Pericardium jung-gyuck (SA-acu-PC) and Triple Energizer jung-gyuck (SA-acu-TE) on the radial pulse in healthy human subjects. Methods: Sixty healthy subjects participated in this study and divided into three groups randomly: Control group(C), Pericardium jung-gyuck group(PC), Triple Energizer jung-gyuck group(TE). Radial pulse was measured by 3 dimensional pulse imaging system (DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture. Results: 1. The changes observed in periodic parameters are considered as the common effects of both SA-acu-TE and SA-acu-PC. SA-acu-TE was more effective than SA-acu-PC in these effects. 2. The effects of SA-acu-PC appeared in the pulse amplitude, pulse area, and pulse power volume mainly at the left chon position, and 3. The effects of SA-acu-TE appeared in the radial augmentation index and main peak angle mainly at the right gwan position. Conclusions: The effects of SA-acu-PC and SA-acu-TE can be observed in the radial pulse. The increases in pulse amplitude, pulse area, and pulse power volume at the left chon may imply the effects of SA-acu-PC. And the decrease in the pulse power volume, the increases in radial augmentation index and main peak angle may imply the effects of SA-acu-TE.