• Title/Summary/Keyword: Pulse amplitude

Search Result 497, Processing Time 0.037 seconds

ZigBee 무선통신 기술을 이용한 뇌졸중 환자 치료용 뇌자극기 개발 (A Plastic Cortex Stimulator for Stroke Recovery Using ZigBee technology)

  • 김국화;양윤석;이상민;김남균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.373-375
    • /
    • 2005
  • The purpose of this paper is to develop the Plastic Cortex Stimulator(PCS) for stroke patients using ZigBee technology. The PCS consists of an implantable neuro-stimulator and a user controller, The neuro-stimulator has the stimulus circuit which is the H-bridge circuit to generate a bipolar pulse. The bipolar pulse is known to be effective for stroke recovery. The user controller sends several wave-shape parameters (amplitude, pulse width, cycle, etc.) to the neuro-stimulator for variable stimulation using ZigBee technology. The CC2420 and atmega128L was used to implement ZigBee protocol stack. The wireless control of PCS based on ZigBee can help the tele-rehabilitation of the stroke patients. The most effective pulse shape parameters are being investigated through animal experiments. The bio-compatibility and user-friendly interface are supposed to be handled in further study.

  • PDF

분포정수회로를 이용한 고전압 급준 펄스 연구 (A Study on the Very Fast Rising High Voltage Pulse Using Distributed Circuit)

  • 곽희로;권동진;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.274-277
    • /
    • 1994
  • This paper describes a very fast rising high voltage pulse generation for studying surge phinomenon and prebreakdown of liquid dielectric by appling the traveling wave theory of the distributed circuit. This very fast rising high voltage pulse generator consists of a charging coaxial cable, a discharging switch, and a terminating resistance. As results, the rising time of pulses are about 31(nsec), which is very fast, and its duration is 950[nsec] when using 200[m] coaxial cable. The length of the coaxial cable and changing voltage can regulate the duration and the amplitude or the polarity of the pulse. When terminated the resistance, capacitor and inductor, the measured waveform corresponds with simulated waveform.

  • PDF

Optimal condition for efficient DNA transfer in filamentous cyanobacteria by electroporation

  • Poo, Ha-Ryoung
    • Journal of Microbiology
    • /
    • 제35권3호
    • /
    • pp.181-187
    • /
    • 1997
  • Filamentous cyanobacteria are an ecologically important group of bacteria because they are able to provide both organic carbon fixed nitrogen that can support the nutritional requirements for other microorganisms. Because of their prokaryotic nature, they can also be used as potentially powerful model systems for the analysis of oxygenic photosynthesis and nitrogen fixation. Gene transfer is an indispensable procedure for genetic analysis of filamentous cyanobacteria. Electroporation was used to introduce foreign DNA into cyanobacterial cells. In experiments designed to optimize the electroporation technique, the effects of the field strength (amplitude of pulse) and time constant (duration of pulse), DNA concentration and host restriction/modification of DNA on the efficiency of electro-transformation were investigated. The results of this research revelaed that a high voltage pulse of short duration was effective for the electro-transformation of Anabaene sp. M131. The maximal number of transformants was obtained at 6 kV/cm with a pulse duration of 5 msec. The efficiency of electro-transformation was also sensitive to concenetration of DNA; even small amounts of DNA (0.01 .mu.g/ml) were able to gie a large number of transformants (1.0 * 10$\^$3/ cfu/ml).

  • PDF

3채널 지연선을 가진 디지털주파수판별기의 설계에 관한 연구 (A Study on the Design of Digital Frequency Discriminator with 3-Channel Delay Lines)

  • 김승우;최재인;진희철
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.44-52
    • /
    • 2017
  • 본 논문에서는 전자전장비에 사용할 수 있는 주파수 분석의 정확도가 높으면서 소형화된 디지털주파수판별기 설계방안을 제안하였다. 전자전 장비는 레이더 신호로부터 주파수, 펄스폭, 펄스도착시간, 신호세기, 도달 방위각, 펄스 내 신호변조 등의 정보를 분석할 수 있어야 한다. 전자전장비는 레이더의 매우 좁은 펄스(100ns 이하) 신호를 분석 할 수 있어야 한다. 따라서 전자전장비는 특별한 형태의 수신기 구조가 필요하며, 주파수 측정을 위하여 순시주파수측정방식 구조의 설계가 일반적으로 사용된다. 이 중 대표적으로 사용되는 방식이 디지털주파수판별기다. 기존 디지털주파수판별기는 회로 소자가 개별부품으로 구성되어 부피와 중량이 크며, 고가인 단점이 있다. 이러한 단점을 보완하기 위해, 기존의 디지털주파수판별기는 4개의 지연선($1{\lambda}$, $4{\lambda}$, $16{\lambda}$, $64{\lambda}$)을 사용하는 반면, 제안한 디지털주파수판별기는 3개의 지연선($1{\lambda}$, $4{\lambda}$, $16{\lambda}$)을 사용하였으며, 국내에서도 비약적인 발전을 하고 있는 마이크로 집적회로 기법으로 설계하였다. 주파수 정확도를 향상하기 위한 방법으로 신호세기 검출과 온도보정을 실시하였다. 제안한 디지털주파수판별기는 실험결과 1.5MHz 이하의 높은 주파수정확도를 가지는 것을 확인하였다. 이것은 국외 도입되는 디지털주파수판별기보다 우수한 성능을 가진다고 볼 수 있다.

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구 (A Study on Evaluation of Human Arousal Level using PPG Analysis)

  • 김치중;황민철;김종화;우진철;김용우;김지혜
    • 대한인간공학회지
    • /
    • 제29권1호
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

다중사용자 환경에서 공간적인 다이버시티를 이용하는 초광대역 통신시스템의 성능 비교분석 (Performance of UWB Systems using Spatial Diversity in Multi-User Environments)

  • 백선영;안진영;이성신;김상준
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.321-324
    • /
    • 2007
  • 본 논문에서는 다중 수신안테나가 제공하는 공간적인 다이버시티를 이용하여 고속의 데이터 전송률을 달성하기 위한 초광대역 통신시스템의 성능 향상에 대해 연구한다. 다중사용자 간섭 신호들이 존재하는 환경에서 2PPM (Binary Pulse Position Modulation) THMA (Time Hopping Multiple Access) UWB 시스템의 성능을 이론적으로 분석하기 위해서 다중 수신안테나를 통해서 수신되는 공간적인 신호들을 결합한 후의 수신 SINR 표현식을 유도하고 BER 성능을 수치적인 시뮬레이션에 의해 평가된다. 또한 2PPM에 의한 시스템의 성능 결과들을 2PAM (Binary Pulse Amplitude Modulation) THMA UWB 시스템의 이론적인 성능 결과와도 비교한다. 공간적인 다이버시티가 2PPM과 2PAM THMA UWB 시스템의 성능에 미치는 영향을 분석한다. 다중 수신안테나의 수가 증가함에 따라 BER 성능이 향상됨을 보인다. 또한 다중사용자 간섭 신호들이 존재할 때 2PAM THMA UWB 시스템의 성능이 2PPM THMA UWB 시스템의 성능보다 상당히 우수하다는 것을 확인하다.

  • PDF

다중사용자 환경에서 공간적인 다이버시티를 이용하는 초광대역 통신시스템의 성능 비교분석 (Performance of UWB Systems using Spatial Diversity in Multi-User Environments)

  • 백선영;안진영;이성신;김상준
    • 한국정보통신학회논문지
    • /
    • 제11권11호
    • /
    • pp.2121-2126
    • /
    • 2007
  • 본 논문에서는 다중 수신안테나가 제공하는 공간적인 다이버시티를 이용하여 고속의 데이터 전송률을 달성하기 위한 초광대역 통신시스템의 성능 향상에 대해 연구한다. 다중사용자 간섭 신호들이 존재하는 환경에서 2PPM(Binary Pulse Position Modulation) THMA(Time Hopping Multiple Access) UWB 시스템의 성능을 이론적으로 분석하기 위해서 다중 수신안테나를 통해서 수신되는 공간적인 신호들을 결합한 후의 수신 SINR 표현식을 유도하고 BER 성능을 수치적인 시뮬레이션에 의해 평가된다. 또한 2PPM에 의한 시스템의 성능 결과들을 2PAM(Binary Pulse Amplitude Modulation) THMA UWB 시스템의 이론적인 성능 결과와도 비교한다. 공간적인 다이버시티가 2PPM과 2PAM THMA UWB 시스템의 성능에 미치는 영향을 분석한다. 다중 수신안테나의 수가 증가함에 따라 BER 성능이 향상됨을 보인다. 또한 다중사용자 간섭 신호들이 존재할 때 2PAM THMA UWB 시스템의 성능이 2PPM THMA UWB 시스템의 성능보다 상당히 우수하다는 것을 확인한다.

안정한계 선형전류펄스변별기 (A Stable Threshold Linear Current Pulse Discriminator)

  • 김병찬
    • 대한전자공학회논문지
    • /
    • 제5권2호
    • /
    • pp.8-14
    • /
    • 1968
  • 트란지스타 단일안정 멀티바이부래타(monostable multi-vibrator)와 시리콘턴넬 다이오드 (T.D)로써 구성된 전류파 파고변별기를 설계하여 그 특성을 조사하였다. 피측정 전류액의 범위는 50㎂-5.23mA이며, 이 범위에 있어서 측정된 최대비직선도는 ±0.75% 이었다. 이 변별기의 전류액 분해능은 T.D를 통하여 흐르는 편의전류에 따라서 약간 달라지며 역방향 편의전류가 3 mA 일때, 만일 5%의 과잉파고를 주용한다면 그 분해시간은 2μS이다. 다음에 이 변별기의 임계치 안정도는 주로 T.D의 턴넬전류의 최대치 1 의 안정도에 의하여 좌우되며 환경온도의 변화범위가 0℃∼50℃일때는 최대비직선도 즉 ±0.75T 보다 더큰 임계치변화는 관측되지 않았다.

  • PDF

누설전류 파고분석에 의한 전력설비의 열화진단 기술 (Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current)

  • 한주섭;김명진;손원진;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.367-370
    • /
    • 2001
  • 본 논문에서는 누설전류 파고분석을 이용한 전력선비의 새로운 열화 진단법을 제안하였다. 현재까지 여러가지 열화 진단법이 제안되었으며, 평가요소로 누설전류의 크기만을 이용하는 것이 일반적이었다. 본 연구에서는 피뢰기, 케이블 등의 전력설비들이 열화가 진전됨에 따라 누설전류의 파고분포도 크게 달라짐을 알 수 있었다. 따라서 전력설비의 열화진단에 누설전류의 파고분포를 이용하면 기존의 누설전류의 크기만을 이용하는 방법보다 더 정확한 평가가 가능하다. 피뢰기, 케이블을 이용한 여러 가지 적용실험으로부터 제안한 열화 진단법은 충분한 성능이 있음을 확인하였다.

  • PDF