• 제목/요약/키워드: Pulse amplitude

검색결과 497건 처리시간 0.026초

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥파의 주파수 분석 (A Study on the Effect of Food Intake on Radial Pulse using Fourier Analysis)

  • 임윤경;박광석
    • 대한한의학회지
    • /
    • 제32권4호
    • /
    • pp.139-148
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the effect of food intake on the Fourier components of radial pulse wave. Methods: Thirty-one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Fourier transform was performed and the frequency and amplitude of Fourier components were analyzed. Results: 1. The frequency and the amplitude of Fourier components of radial pulse wave increased significantly after food intake. 2. The frequency of Fourier components increased right after food intake and then gradually decreased as time passed, however the amplitude of Fourier components increased and maintained certain levels and patterns throughout the experimental period of 120 minutes. 3. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations. Conclusions: Food intake exerts an influence on radial pulse wave, resulting in increase of frequency and amplitude of Fourier components. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations.

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥압 변화 연구 (The Effect of Food Intakes on Radial Pulse Amplitude)

  • 임윤경;강희정;이병렬;양기영;이현;김경철
    • Korean Journal of Acupuncture
    • /
    • 제28권2호
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : The purpose of this study is to investigate the effect of food intake on radial pulse amplitude. Methods : Thirty one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Results : 1. The amplitude of h1 increased significantly right after food intake compared to 'before food intake' at all 6 measuring points. Later on, it decreased back as time passed, however, even 120 minutes later, it was still higher than 'before food intake' 2. Pulse energy, which is calculated from pulse waves acquired with five sensors, increased after food intake as well. Conclusions : Food intake exerts an influence on radial pulse amplitude, resulting in increase of h1 and pulse energy.

자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색 (Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device)

  • 유준상;장세진;선승호;홍유식;이상석
    • 대한한의진단학회지
    • /
    • 제17권1호
    • /
    • pp.63-76
    • /
    • 2013
  • The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.

일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성 (Muscle Force Potentiation During Constant Electrical Stimulation - Dependence on Pulse-Amplitude and Pulse-Duration of Electrical Stimulation)

  • 김지원;강민영;엄광문
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권10호
    • /
    • pp.458-463
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration with different ramp-up time. The experimental results showed that the force increment ratio (FIR) during constant electrical stimulation decreased with pulse-amplitude and also with pulse-duration. The FIR was greater with short ramp-up time in both the pulse-amplitude and pulse-width modulation. The feasible mechanism might be that the myosin light chain phosphorylation induces the force potentiation and it occurs only in the fast type muscle fibers which are recruited first. These observations indicate that muscle potentiation must be understood well for the accurate control of muscle force.

과학로켓 탑재부 자세제어를 위한 펄스 진폭 변조 제어기 설계 (Design of Pulse Amplitude Modulation Controller for the Attitude Control of the Payload of a Sounding Rocket)

  • 공현철;전상운
    • 제어로봇시스템학회논문지
    • /
    • 제6권11호
    • /
    • pp.981-986
    • /
    • 2000
  • A pulse amplitude modulation(PAM) controller is designed for the 3 axis attitude control of a sounding rocket. a certain number of fixed level of thrust are used for the pulse amplitude modulation and the nonlinearity of the controller is considered to examine the existence of the limit cycles and the stability analysis is carried out with the aid of Nyquist plot.

  • PDF

위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향 (The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 최주영;강재희;임윤경;이현
    • Journal of Acupuncture Research
    • /
    • 제29권6호
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

A Discrete-Amplitude Pulse Width Modulation for a High-Efficiency Linear Power Amplifier

  • Jeon, Young-Sang;Nam, Sang-Wook
    • ETRI Journal
    • /
    • 제33권5호
    • /
    • pp.679-688
    • /
    • 2011
  • A new discrete-amplitude pulse width modulation (DAPWM) scheme for a high-efficiency linear power amplifier is proposed. A radio frequency (RF) input signal is divided into an envelope and a phase modulated carrier. The low-frequency envelope is modulated so that it can be represented by a pulse whose area is proportional to its amplitude. The modulated pulse has at least two different pulse amplitude levels in order that the duty ratios of the pulse are kept large for small input. Then, an RF pulse train is generated by mixing the modulated envelope with the phase modulated carrier. The RF pulse train is amplified by a switching-mode power amplifier, and the original RF input signal is restored by a band pass filter. Because duty ratios of the RF pulse train are kept large in spite of a small input envelope, the DAPWM technique can reduce loss from harmonic components. Furthermore, it reduces filtering efforts required to suppress harmonic components. Simulations show that the overall efficiency of the pulsed power amplifier with DAPWM is about 60.3% for a mobile WiMax signal. This is approximately a 73% increase compared to a pulsed power amplifier with PWM.

전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구 (The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal)

  • 임경민;송동진
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

전자전 지원을 위한 향상된 펄스 세기 추정 기법 (Enhanced Pulse Amplitude Estimation Method for Electronic Warfare Support)

  • 이유리;김동규;곽현규;김형남
    • 한국통신학회논문지
    • /
    • 제42권3호
    • /
    • pp.649-660
    • /
    • 2017
  • 전자전에서 적군이 방사한 펄스 신호에 관한 정보 중에서 펄스 세기는 방사되는 신호원의 거리를 추정하고 혼재되어 들어오는 신호원들을 분리할 때 사용된다. 기존의 펄스 세기 추정 방식에서는 이전 단계에서 추정된 펄스폭에 해당하는 신호를 푸리에 변환한 후에 주파수 영역으로 변환된 신호 세기의 최댓값을 수신된 펄스 신호의 세기로 추정을 하였다. 하지만 이러한 방식은 주파수 변조 신호가 수신될 경우 주파수 영역에서 에너지가 분산되어 펄스 세기를 정확하게 추정하기 어렵다. 본 논문에서는 이러한 단점을 개선하기 위하여 시간 영역에서 수신된 펄스의 평균 전력을 구하고 수신기에서의 잡음의 평균 전력을 제거하여 펄스 세기를 추정하는 기법을 제안한다. 모의실험을 통해 주파수 변조 신호가 수신될 경우에 제안된 기법이 무변조 신호와 동일한 성능을 가지는 것을 보인다. 추가로 펄스 세기 추정은 이전 단계에서 발생한 펄스 폭 오차에 영향을 받게 되는데, 동일한 펄스 폭의 오차가 발생했을 때 기존 기법보다 제안하는 기법이 강건함을 보인다.

일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성 (Muscle force potentiation during constant electrical stimulation - Dependence on pulse-amplitude and pulse-duration of electrical stimulation)

  • 김지원;강민영;공세진;엄광문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2155-2156
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation for the prediction of muscle force and body movement from the stimulation input with musculo-skeletal model. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration. The experimental result showed that the force increment ratio during electrical stimulation decreased with pulse-amplitude. The force increment ratio decreased with short pulse-duration and was maintained to be constant with pulse-duration longer than $500{\mu}s$. A new model of the muscle potentiation based on these results is desired in the future.

  • PDF