• Title/Summary/Keyword: Pulse amplitude

Search Result 495, Processing Time 0.03 seconds

A Study on the Effect of Food Intake on Radial Pulse using Fourier Analysis (음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥파의 주파수 분석)

  • Yim, Yun-Kyoung;Park, Kwang-Suk
    • The Journal of Korean Medicine
    • /
    • v.32 no.4
    • /
    • pp.139-148
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the effect of food intake on the Fourier components of radial pulse wave. Methods: Thirty-one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Fourier transform was performed and the frequency and amplitude of Fourier components were analyzed. Results: 1. The frequency and the amplitude of Fourier components of radial pulse wave increased significantly after food intake. 2. The frequency of Fourier components increased right after food intake and then gradually decreased as time passed, however the amplitude of Fourier components increased and maintained certain levels and patterns throughout the experimental period of 120 minutes. 3. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations. Conclusions: Food intake exerts an influence on radial pulse wave, resulting in increase of frequency and amplitude of Fourier components. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations.

The Effect of Food Intakes on Radial Pulse Amplitude (음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥압 변화 연구)

  • Yim, Yun-Kyoung;Kang, Hee-Jung;Lee, Byung-Ryul;Yang, Gi-Young;Lee, Hyun;Kim, Kyung-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.28 no.2
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : The purpose of this study is to investigate the effect of food intake on radial pulse amplitude. Methods : Thirty one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Results : 1. The amplitude of h1 increased significantly right after food intake compared to 'before food intake' at all 6 measuring points. Later on, it decreased back as time passed, however, even 120 minutes later, it was still higher than 'before food intake' 2. Pulse energy, which is calculated from pulse waves acquired with five sensors, increased after food intake as well. Conclusions : Food intake exerts an influence on radial pulse amplitude, resulting in increase of h1 and pulse energy.

Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device (자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색)

  • Yu, Jun-Sang;Chang, Sei-Jin;Sun, Seung-Ho;Hong, Yu-Sik;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.1
    • /
    • pp.63-76
    • /
    • 2013
  • The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.

Muscle Force Potentiation During Constant Electrical Stimulation - Dependence on Pulse-Amplitude and Pulse-Duration of Electrical Stimulation (일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성)

  • Kim, Ji-Won;Kwang, Min-Young;Eom, Gwang-Moon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.458-463
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration with different ramp-up time. The experimental results showed that the force increment ratio (FIR) during constant electrical stimulation decreased with pulse-amplitude and also with pulse-duration. The FIR was greater with short ramp-up time in both the pulse-amplitude and pulse-width modulation. The feasible mechanism might be that the myosin light chain phosphorylation induces the force potentiation and it occurs only in the fast type muscle fibers which are recruited first. These observations indicate that muscle potentiation must be understood well for the accurate control of muscle force.

Design of Pulse Amplitude Modulation Controller for the Attitude Control of the Payload of a Sounding Rocket (과학로켓 탑재부 자세제어를 위한 펄스 진폭 변조 제어기 설계)

  • Gong, Hyeon-Cheol;Jeon, Sang-Woon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.11
    • /
    • pp.981-986
    • /
    • 2000
  • A pulse amplitude modulation(PAM) controller is designed for the 3 axis attitude control of a sounding rocket. a certain number of fixed level of thrust are used for the pulse amplitude modulation and the nonlinearity of the controller is considered to examine the existence of the limit cycles and the stability analysis is carried out with the aid of Nyquist plot.

  • PDF

The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향)

  • Choi, Joo Young;Kang, Jae Hui;Yim, Yun Kyong;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.6
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

A Discrete-Amplitude Pulse Width Modulation for a High-Efficiency Linear Power Amplifier

  • Jeon, Young-Sang;Nam, Sang-Wook
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.679-688
    • /
    • 2011
  • A new discrete-amplitude pulse width modulation (DAPWM) scheme for a high-efficiency linear power amplifier is proposed. A radio frequency (RF) input signal is divided into an envelope and a phase modulated carrier. The low-frequency envelope is modulated so that it can be represented by a pulse whose area is proportional to its amplitude. The modulated pulse has at least two different pulse amplitude levels in order that the duty ratios of the pulse are kept large for small input. Then, an RF pulse train is generated by mixing the modulated envelope with the phase modulated carrier. The RF pulse train is amplified by a switching-mode power amplifier, and the original RF input signal is restored by a band pass filter. Because duty ratios of the RF pulse train are kept large in spite of a small input envelope, the DAPWM technique can reduce loss from harmonic components. Furthermore, it reduces filtering efforts required to suppress harmonic components. Simulations show that the overall efficiency of the pulsed power amplifier with DAPWM is about 60.3% for a mobile WiMax signal. This is approximately a 73% increase compared to a pulsed power amplifier with PWM.

The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal (전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구)

  • Lim, Kyeong Min;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

Enhanced Pulse Amplitude Estimation Method for Electronic Warfare Support (전자전 지원을 위한 향상된 펄스 세기 추정 기법)

  • Lee, Yu-Ri;Kim, Dong-Gyu;Kwak, Hyungyu;Kim, Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.3
    • /
    • pp.649-660
    • /
    • 2017
  • In electronic warfare, the pulse amplitude, one of information of a pulse signal emitted by an enemy, is used for estimating distance from the source and for deinterleaving mixed source signals. An estimate of pulse amplitude is conventionally determined as the maximum magnitude of a Fourier transformed signal within its pulse width which is estimated pre-step in an electronic warfare receiver. However, when frequency modulated signals are received, it is difficult to estimate their pulse amplitudes with this conventional method because the energy of signals is dispersed in frequency domain. In order to overcome this limitation, this paper proposes an enhanced pulse amplitude estimation method which calculates the average power of the received pulse signal in time domain and removes the noise power of the receiver. Simulation results show that even in case the frequency modulated signal is received, the proposed method has the same performance as estimating the pulse amplitude when unmodulated signal is received. In addition, the proposed method is shown to be more robust to an estimation error of pulse width, which affects the estimation performance of pulse amplitude, than the conventional method.

Muscle force potentiation during constant electrical stimulation - Dependence on pulse-amplitude and pulse-duration of electrical stimulation (일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성)

  • Kim, Ji-Won;Kang, Min-Young;Kong, Se-Jin;Eom, Gwang-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2155-2156
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation for the prediction of muscle force and body movement from the stimulation input with musculo-skeletal model. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration. The experimental result showed that the force increment ratio during electrical stimulation decreased with pulse-amplitude. The force increment ratio decreased with short pulse-duration and was maintained to be constant with pulse-duration longer than $500{\mu}s$. A new model of the muscle potentiation based on these results is desired in the future.

  • PDF