• Title/Summary/Keyword: Pulse Waves

Search Result 306, Processing Time 0.025 seconds

A Sham Experiment for the Measurement of Nonlinear Pulse Propagation Characteristics of Blood Vessel Using Bispectral Analysis (바이스펙트럼해석을 이용한 혈관의 비선형 맥동전파특성 계측에 대한 모의실험)

  • 장경영;김경조
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.525-532
    • /
    • 1995
  • In this paper, a new try to measure nonlinear propagation characteristics of the pulse along blood vessel by using bispectral analysis is introduced, and the possibility of its application to the medical diagnosis is shown. In this method, the waveforms of pulse motion of blood vessel at two separated measuring points on the wall were detected from Doppler frequency modulation of transmitted probing ultrasonic waves. Then the auto- and crossbispectrum of detected waveforms are calculated to estimate the quadratic NTF (nonlinear transfer function) between the two measuring positions. In order to show relationships between the NTF and the nonlinear propagation characteristics, computer simulations have been performed. As the propagation distance increases, harmonic frequency components in NTF increases broadly due to the nonlinear effect in the propagation of blood pulse. In order to represent this phenomena quantitatively, we propose a new parameter, dispersion ratio of WTF. Basic experimental system was constructed by using 3.5MHz probing ultrasonic waves and the preliminary experiments were carried out on ague phantom and human body. Experimental results showed the validity of the measurement system enoughly.

  • PDF

Nondestructive Evaluation in the Defects of FRP Composites By Using Terahertz Waves (테라헤르츠파를 이용한 FRP 복합재료의 비파괴결함평가)

  • Im, Kwang-Hee;Kim, Ji-Hoon;Hsu, David K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.252-258
    • /
    • 2012
  • A study of terahertz waves was made for the nondestructive evaluation of FRP (Fiber reinforced plastics) composite materials. The terahertz systems were consisted of time domain spectroscopy (TDS) and continuous wave (CW). The composite materials investigated include both non-conducting polymeric composites and conducting carbon fiber composites. Terahertz signals in the TDS mode resembles that of ultrasound; however, unlike ultrasound, a terahertz pulse was not able to detect a material with conductivity. The CFRP (Carbon fiber reinforced plastics) laminates were utilized for confirming the experimentation in the terahertz NDE. In carbon composites the penetration of terahertz waves is quite limited and the detection of flaws is strongly affected by the angle between the electric field direction of the terahertz waves and the intervening fiber directions. A refractive index (n) was defined as one of mechanical properties; so a method was obtained in order solve the "n" in the material with non-conductivity. The usefulness and limitations of terahertz radiation are investigated for the NDE of FRP composites.

Nondestructive inspection of spent nuclear fuel storage canisters using shear horizontal guided waves

  • Choi, Sungho;Cho, Hwanjeong;Lissenden, Cliff J.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.890-898
    • /
    • 2018
  • Nondestructive inspection (NDI) is an integral part of structural integrity analyses of dry storage casks that house spent nuclear fuel. One significant concern for the structural integrity is stress corrosion cracking in the heat-affected zone of welds in the stainless steel canister that confines the spent fuel. In situ NDI methodology for detection of stress corrosion cracking is investigated, where the inspection uses a delivery robot because of the presence of the harsh environment and geometric constrains inside the cask protecting the canister. Shear horizontal (SH) guided waves that are sensitive to cracks oriented either perpendicular or parallel to the wave vector are used to locate welds and to detect cracks. SH waves are excited and received by electromagnetic acoustic transducers (EMATs) using noncontact ultrasonic transduction and pulse-echo mode. A laboratory-scale canister mock-up is fabricated and inspected using the proposed methodology to evaluate the ability of EMATs to excite and receive SH waves and to locate welds. The EMAT's capability to detect notches from various distances is evaluated on a plate containing 25%-through-thickness surface-breaking notches. Based on the results of the distances at which notch reflections are detectable, NDI coverage for spent nuclear fuel storage canisters is determined.

A Study on Malfunction Mode and Failure Rate Properties of Semiconductor by Impact of Pulse Repetition Rate (펄스 반복률에 의한 반도체 소자의 오동작 모드와 고장률에 관한 연구)

  • Park, Ki-Hoon;Bang, Jeong-Ju;Kim, Ruck-Woan;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.360-364
    • /
    • 2015
  • Electronic systems based on solid state devices have changed to be more complicated and miniaturized as the electronic systems developed. If the electronic systems are exposed to HPEM (high power electromagnetics), the systems will be destroyed by the coupling effects of electromagnetic waves. Because the HPEM has fast rise time and high voltage of the pulse, the semiconductors are vulnerable to external stress factor such as the coupled electromagnetic pulse. Therefore, we will discuss about malfunction behavior and DFR (destruction failure rate) of the semiconductor caused by amplitude and repetition rate of the pulse. For this experiment, the pulses were injected into the pins of general purpose IC due to the fact that pulse injection test enables the phenomenon after the HPEM is coupled to power cables. These pulses were produced by pulse generator and their characteristics are 2.1 [ns] of pulse width, 1.1 [ns] of pulse rise time and 30, 60, 120 [Hz] of pulse repetition rate. The injected pulses have changed frequency, period and duty ratio of output generated by Timer IC. Also, as the pulse repetition rate increases the breakdown threshold point of the timer IC was reduced.

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

Analysis of 2-Dimensional Elasto-Plastic Stress by a Time-Discontinuous Variational Integrator of Hamiltonian (해밀토니안의 시간 불연속 변분적분기를 이용한 2차원 탄소성 응력파 해석)

  • Chol, S.S.;Huh, H.;Park, K.C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.263-266
    • /
    • 2008
  • This paper is concerned with the analysis of elasto-plastic stress waves in a mode I semi-infinite cracked solid subjected to Heaviside pulse load. This study adopts a time-discontinuous variational integrator based on Hamiltonian in order to reduce the numerical dispersive and dissipative errors. This also utilizes an integration scheme of the constitutive model with 2nd-order accuracy which is formulated on the strain space for a rate and temperature dependent material model. Finite element analyses of elasto-plastic stress waves are carried out in order to compare the accuracy between a conventional Galerkin method and the time- discontinuous variational integrator.

  • PDF

A Dual Mode Ultrasonic Transducer with a PZT Piezoelectric Seramics (PZT 압전 세라믹스를 사용한 2 중 모우드 초음파 변환기)

  • 김연보;노용래;남효덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.1-4
    • /
    • 1995
  • The most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigated the mechanism of dual mode transducers that generates both of the longitudinal and shear waves simultaneously with a single PZT element. The study has been aimed to find the desired cut by the examining the piezoelectric properties. Theory predicts that a mixed P/S mode transducer can be constructed using a related Z-cut of a PZT ceramics. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves equally strongly. The results are verified by checking the impedance variation of the element with Finite Element Methods, and chocking the wave form by pulse-echo test simulation. Based upon the theory a rotated Z-cut was prepared and a transducer were fabricated. Validity of the theory calculation is verified through the

  • PDF

Photo-thermo-elastic interaction in a semiconductor material with two relaxation times by a focused laser beam

  • Jahangir, A.;Tanvir, F.;Zenkour, A.M.
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.1
    • /
    • pp.41-52
    • /
    • 2020
  • The effect of relaxation times is studied on plane waves propagating through semiconductor half-space medium by using the eigen value approach. The bounding surface of the half-space is subjected to a heat flux with an exponentially decaying pulse and taken to be traction free. Solution of the field variables are obtained in the form of series for a general semiconductor medium. For numerical values, Silicon is considered as a semiconducting material. The results are represented graphically to assess the influences of the thermal relaxations times on the plasma, thermal, and elastic waves.

Fabrication of Dual-mode Ultrasonic Transducer using PZT

  • Kim, Yeon-Bo;Park, Youn-Rae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.914-920
    • /
    • 2002
  • This study investigates the mechanism of a dual mode probe that generates both of the longitudinal and shear waves simultaneously with a single FZT element. Most of conventional ultrasonic probes are constructed to generate either longitudinal or shear waves. After poling, PZT has the hexagonal 6mm crystal symmetry. All possible crystal cuts are checked to determine appropriate Euler transformation angles for efficient excitation of dual modes. For the selected cut, performance of the dual mode element is analyzed through numerical simulation and experiments. Results of the analysis determine the optimal crystal cut for simultaneous generation of P and S waves of equal strength.

A Study on the Inspection of Orthotropy Composite Laminate plates Using Ultrasonics (직교이방성 복합적층판의 초음파 탐사에 관한 연구)

  • 나승우;임광희;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.583-586
    • /
    • 2000
  • This work ethibits how susceptive the shear ultrasonic waves are to a little misoriented plies according to the angle variation of shear ultrasoic waves $0^\circ$ , $45^\circ$ and $90^\circ$. Also, it is shown that shear waves, particularly the transmission mode with the transmitter and receiver perpendicular to each other, have high sensitivity for detecting anomalies in fiber orientation and ply layup sequence that may occur in the manufacturing of composite laminates. Experimental results are agreed with modeling solutions which were based on decomposition of shear wave polarization vector as it propagates through the composite laminates. This wave appeared considerably to be sensitive to CFRP composites to the thickness direction along in-plane fibers.

  • PDF