• 제목/요약/키워드: Pulse Waves

Search Result 306, Processing Time 0.031 seconds

Analysis of multi-channel photoplethysmograph parameter by the changes of arterial characteries (동맥계 다채널 용적맥파 특징 파라미터 분석에 관한 연구)

  • Han, Soon-Chen;Kim, Hyoung-Jo;Kim, Hyoung-Tae;Kim, Jung-Kuk;Huh, Woong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2745-2748
    • /
    • 2003
  • In this paper, we implement the photoplethysmo-graphy system that have three channel pulse wave detects and one channel ECG amplifier. In order to detect the artery state, we measured the pulse waves at different positions, simultaneously. In general, arterial vascular system suffers the decrease of compliance, increase of resistance, and decrease of distensibility through aging. Therefore, we compared and analyzed variation of tile Pulse waves parameter both in time and frequency domains that is concerned with the changes of arterial characteries. And then evaluated the correlation coefficients between the parameters variation and the age group. As the result of experiment, we found that the Parameters have a significant correlation about aging.

  • PDF

Effect of the laser pulse on transient waves in a non-local thermoelastic medium under Green-Naghdi theory

  • Sarkar, Nantu;Mondal, Sudip;Othman, Mohamed I.A.
    • Structural Engineering and Mechanics
    • /
    • v.74 no.4
    • /
    • pp.471-479
    • /
    • 2020
  • This paper aims to study the effect of the elastic nonlocality on the transient waves in a two-dimensional thermoelastic medium influenced by thermal loading due to the laser pulse. The bounding plane surface is heated by a non-Gaussian laser beam. The problem is discussed under the Eringen's nonlocal elasticity model and the Green-Naghdi (G-N) theory with and without energy dissipation. The normal mode analysis method is used to get the exact expressions for the physical quantities which illustrated graphically by comparison and discussion. The effects of nonlocality and different values of time on the displacement, the stresses, and the temperature were made numerically. All the computed results obtained have been depicted graphically and explained.

Influence of Steel Bar on Ultrasonic Velocity in Concrete (콘크리트 속의 철근이 초음파 속도에 미치는 영향)

  • Kim, Do-Hyun;Rhim, Hong-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.122-123
    • /
    • 2014
  • Measurement of the strength of concrete is an important indicator of the safety of the fresh as well as old concrete structures. It is possible to evaluate the strength of the concrete by means of an ultrasonic velocity method which is a kind of non-destructive inspection method for safety diagnostic evaluation of the building structures with aging. Steel embedded in the concrete and age of the concrete may affect ultrasonic pulse velocity. In order to accurately assess the strength of the concrete, it is necessary to understand rebar embedded in the concrete, steel shapes in various forms which effect ultrasonic pulse velocity. In this study, by measuring the velocity of ultrasonic waves generated when the waves pass through the ultrasonic pulse in a direction perpendicular to the reinforcing bars embedded in concrete, the effect of reinforcing bars on ultrasonic velocity accurately was verified and used to estimate the strength of the concrete.

  • PDF

A Simple Method for Conducting Angle Calculation of Switch Devices in Cascaded Inverters Using Step Pulse Waves (스텝 펄스파를 사용하는 캐스케이드 인버터에서 스위치의 간단한 도통각 계산법)

  • Kim H.C.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.588-592
    • /
    • 2003
  • In recent years, the multilevel inverter synthesizing the output voltage with step pulse has been widely used as a solution for high power and high voltage applications. This paper proposes a simple method to obtain the conducting . angle. It is calculated by using voltage-second areas of the divided reference voltage according to the output voltage levels and these areas have influence on output step pulse waves. It is possible to reduce an amount of calculation because it is not required to solve the simultaneous equations by an iterative method. Also, the proposed method can get the conducting angle by means of on line.

  • PDF

Spin Wave Interference in Magnetic Nanostructures

  • Yang, Hyun-Soo;Kwon, Jae-Hyun;Mukherjee, Sankha Subhra;Jamali, Mahdi;Hayashi, Masamitsu
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2011.12a
    • /
    • pp.7-8
    • /
    • 2011
  • Although yttrium iron garnet (YIG) has provided a great vehicle for the study of spin waves in the past, associated difficulties in film deposition and device fabrication using YIG had limited the applicability of spin waves to practical devices. However, microfabrication techniques have made it possible to characterize both the resonant as well as the travelling characteristics of spin waves in permalloy (Py). A variety of methods have been used for measuring spin waves, including Brillouin light scattering (BLS), magneto-optic Kerr effect (MOKE), vector network analyzer ferromagnetic resonance (VNA-FMR), and pulse inductive microwave magnetometry (PIMM). PIMM is one of the most preferred methodologies of measuring travelling spin waves. In this method, an electrical impulse is applied at one of two coplanar waveguides patterned on top of oxide-insulated Py, producing a local disturbance in the magnetization of the Py. The resulting disturbance travels down the Py in the form of waves, and is inductively picked up by the other coplanar waveguide. We investigate the effect of the pulse width of excitation pulses on the generated spin wave packets using both experimental results and micromagnetic simulations. We show that spin wave packets generated from electrical pulses are a superposition of two separate spin wave packets, one generated from the rising edge and the other from the falling edge, which interfere either constructively or destructively with one another, depending upon the magnitude and direction of the field bias conditions. A method of spin wave amplitude modulation is also presented by the linear superposition of spin waves. We use interfering spin waves resulting from two closely spaced voltage impulses for the modulation of the magnitude of the resultant spin wave packets.

  • PDF

Estimation of the Central Aortic Pulse using Transfer Function and Improvement of an Augmentation Point Detection Algorithm (전달함수를 이용한 대동맥 맥파 추정 및 증강점 검출 알고리즘 개선에 관한 연구)

  • Im, Jae-Joong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.68-79
    • /
    • 2008
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness quantitatively and even to evaluate ventricular load. However, in order to calculate aortic AIx catheters should be inserted to the subjects' artery, which hampers its clinical usage. To overcome such limitation, aortic AIx has been indirectly calculated by estimating aortic pressure wave from the peripheral arterial pulse by applying transfer functions. In this study, central aortic pressure waves using Millar catheter and radial artery pulse waves using tonometry pressure sensor were measured to establish transfer functions for an estimation of central aortic pressure waves from radial artery pulse waves. Also, an algorithm which detects augmentation point for the calculation of AIx were developed. Developed algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Transfer functions were established using 10th order ARX model and were verified for the stability of the transfer function through residual analysis. Evaluation of an algorithm for the detection of augmentation point were performed by comparing the augmentation points obtained from developed algorithm with the known augmentation points synthesized in various conditions. In addition, developed algorithm for the AIx is proved to provide more accurate results than the ones developed by previous studies. The significance of the study was in two folds. Firstly, the results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and secondly, extension of the study may enable the early diagnosis of various vascular diseases.

Stress Wave Reduction of Structures Using MR Inserts (MR Insert를 이용한 구조물의 응력파 저감)

  • 강병우;김재환;최승복;김경수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.4
    • /
    • pp.71-77
    • /
    • 2001
  • In this paper, stress wave propagation characteristics of MR(Magneto-rheological) inserts are experimentally investigated. Generally, stress waves of structures such as warships or submarines are induced by shock waves from underwater explosion. Their fatal effects on the shipboard equipments or structures damage the performance of warships. But, such a problem can be solved by controlling the stress waves propagating through structures by means of MR inserts. MR insert consists of two aluminum layers and MR fluid filled in between. Two piezoceramic disks are embedded on the host plate as a transmitter and a receiver of stress waves. Pulse waves are generated by the transmitter and they reach to the receiver through the MR insert. Permanent magnet and magnetic coil are used to produce magnetic field at the MR insert. In the presence of magnetic field, MR particles are arranged in chains parallel to the magnetic field such that the transmitted stress waves are reduced. Attenuation of stress waves is experimentally investigated.

  • PDF

Analysis of Simultaneous Generation Mechanism of P/S Waves with the PZT Piezoelectric Ceramics (PZT압전 세라믹스의 종$\cdot$횡파 동시 발생 기구의 해석)

  • Kim, Yeon-Bo;Roh, Yong-Rae;Nam, Hyo-Duk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 1995
  • Most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigated the mechanism of dual mode transducers that generates both of the longitudinal and shear waves simultaneously with a single PZT element. A piezoelectric ceramic PZT has the hexagonal 6mm crystal symmetry, after poling. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves equally strongly. The results are verified by checking the impedance variation of the element with Finite Element Methods, and checking the wave form by pulse-echo test simulation. Validity of the theoretical calculation is verified through experiments.

  • PDF

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

Experiment Research of Autonomous Driving Valve for Pulse Detonation Rocket Engine

  • Matsuoka, Ken;Yamaguchi, Hiroyuki;Nemoto, Toyoshi;Yageta, Jun;Kasahara, Jiro;Yajima, Takashi;Kojima, Takayuki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.419-426
    • /
    • 2008
  • As pulse detonation engine(PDE) does not need compression mechanisms such as compressors because self-sustained detonation waves are able to compress propellant gases by their incident shock waves, the PDE can have a simple straight-tube structure. In this study, we propose an autonomous driving valve system of the PDE, which fill premixed gases into the PDE tubes at high frequency with high mass flow rate. The proposed valve is composed of only three parts: a piston, a cylinder, and a spring. This valve system can produce intermittent flow at high mass flow rate, and also can keep stable reciprocal motion by using the propellant-gas enthalpy. When the cylinder content product is assumed to be constant, experimental results of the mass flow rate were approximately equal to the calculation model. We confirmed the autonomous driving valve performance by experiments, and concluded that this extremely simple valve with no electrical power and controller can be used as the PDE propellant supply system.

  • PDF