• Title/Summary/Keyword: Pulse Waves

Search Result 306, Processing Time 0.026 seconds

Transjugular occlusion of patent ductus arteriosus using an Amplatz canine ductal occluder in a Cocker spaniel dog

  • Choi, Ran;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • A 5-year-old female Cocker spaniel dog (body weight 7.0 kg) was presented with primary complaints of exercise intolerance and loud precordial thrill which was noticed since she was a puppy. Physical examination revealed a grade V/VI continuous murmur over the maximal point of the left basal area, bounding femoral pulse, but no differential cyanosis. Tall R waves were detected in electrocardiogram, suggesting left ventricular enlargement. Diagnostic imaging studies showed enlarged left ventricle, bulged descending aorta (dAo), markedly dilated right pulmonary artery, and continuous shunt flow between the dAo and main pulmonary artery. Based on these findings, the dog was diagnosed as left to right shunted patent ductus arteriosus (PDA). The patent ductus arteriosus was treated by lodging a PDA duct occluder via the transvenous approach. Clinical signs were markedly improved after the ductal occlusion, the shunt flow was mildly persistent. The case presented is the first case of PDA occluded by the PDA duct occluder via the transvenous approach in a small breed of dog. Although the residual shunt flow was mildly persisted, the dog was clinically normal without detectable murmurs.

A Study on Couplant Medium Improvement for Ultrasonic Inspection System with Water Immersion to Detect Weld Defects (용접결함 검사용 수침식초음파탐상기의 매질개선연구)

  • Jung, Dal-Woo;Choi, Nak-Sam;Park, Yong-Bae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.8-14
    • /
    • 2008
  • For nondestructive inspection of electron beam (EB) welding part in automotive power transmission assembly, a pulse-echo ultrasonic testing apparatus in water immersion has been applied using the ultrasonic waves with a frequency of 10MHz. However various problems have appeared during the ultrasonic inspection, which led to some significant mistakes in automatic quality evaluation of the welding parts. Experimental study showed that the state of water couplant medium containing some amount of contaminants, rusts and anti-corrosion agents had considerable influences on the reduction of ultrasonic amplitudes during wave propagation. The amplitude reduction depending on the coupling medium state could bring about some mis-diagnoses for defects in the welding parts. The results proposed that for a reliable inspection of defects in welds the state of water medium should be kept in about 15 volume fractions (vol.%) of anti-corrosion agents and in minimized contaminants.

Dynamic elastic local buckling of piles under impact loads

  • Yang, J.;Ye, J.Q.
    • Structural Engineering and Mechanics
    • /
    • v.13 no.5
    • /
    • pp.543-556
    • /
    • 2002
  • A dynamic elastic local buckling analysis is presented for a pile subjected to an axial impact load. The pile is assumed to be geometrically perfect. The interactions between the pile and the surrounding soil are taken into account. The interactions include the normal pressure and skin friction on the surface of the pile due to the resistance of the soil. The analysis also includes the influence of the propagation of stress waves through the length of the pile to the distance at which buckling is initiated and the mass of the pile. A perturbation technique is used to determine the critical buckling length and the associated critical time. As a special case, the explicit expression for the buckling length of a pile is obtained without considering soil resistance and compared with the one obtained for a column by means of an alternative method. Numerical results obtained show good agreement with the experimental results. The effects of the normal pressure and the skin friction due to the surrounding soil, self-weight, stiffness and geometric dimension of the cross section on the critical buckling length are discussed. The sudden change of buckling modes is further considered to show the 'snap-through' phenomenon occurring as a result of stress wave propagation.

Shear Wave Velocity in Unconsolidated Marine Sediments of the Western Continental Margin, the East Sea

  • Kim, Gil-Young;Kim, Dae-Choul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4E
    • /
    • pp.167-175
    • /
    • 2003
  • Shear wave velocity was measured and grain size analysis was conducted on two core samples obtained in unconsolidated marine sediments of the western continental margin, the East Sea. A pulse transmission technique based on the Hamilton frame was used to measure shear wave velocity. Duomorph ceramic bender transducer-receiver elements were used to generate and detect shear waves in sediment samples. Time delay was calculated by changing the sample length from the transducer-receiver element. Time delay is 43.18 μs and shear wave velocity (22.49 m/s) is calculated from the slope of regression line. Shear wave velocities of station 1 and 2 range from 8.9 to 19.0 m/s and from 8.8 to 22 mis, respectively. Shear wave velocities with depth in both cores are qualitatively in agreement with the compared model〔1〕, although the absolute value is different. The sediment type of two core samples is mud (mean grain size, 8-9Φ). Shear wave velocity generally increases with sediment depth, which is suggesting normally consolidated sediments. The complicated variation of velocity anisotropy with depth at station 2 is probably responsible for sediment disturbance by possible gas effect.

Power Loss Analysis of Transformer Caused By Current Harmonics (전류 고조파에 기인하는 변압기 손실 해석)

  • Jang, Seungyong;Han, Sanghoon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.34-41
    • /
    • 2016
  • This study investigates transformer losses caused by current harmonics. Electrical transformers are designed to work under sinusoidal voltage and current waves at a rated frequency. Recently, various nonlinear loads, such as power electronic converters, are connected to a power system; these converters generate current harmonics. Current harmonics increase power loss in transformers, which results in several problems, including temperature increase of the transformer and insulation damage. These problems will eventually shorten the operational life of the transformer. In this study, different types of losses caused by current harmonics in three-phase transformers are studied under linear and nonlinear load conditions. Linear loads are simulated and experimented on using pure resistance load, whereas nonlinear loads are simulated and experimented on using a three-phase twelve-pulse thyristor full-bridge rectifier. The different types of losses in three-phase transformers are evaluated analytically through the experimental result and simulation in PSiM.

Nondestructive Evaluation of the Turbine Blade of Wind Energy By Using T-Ray (T-ray를 이용한 풍력터빈 브레이드 비파괴결함평가)

  • Im, Kwang-Hee;Jeong, Jong-An;Hsu, David K.;Lee, Kil-Sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.102-108
    • /
    • 2012
  • A study of terahertz waves (T-ray) was made for the nondestructive evaluation of FRP (Fiber reinforced plastics) composite materials. The to-be-used systems were time domain spectroscopy (TDS) and continuous wave (CW). The composite materials investigated include both turbine blades of wind energy (non-conducting polymeric composites) and conducting carbon fiber composites. Terahertz signals in the TDS mode resembles that of ultrasound; however, unlike ultrasound, a terahertz pulse was not able to detect a material with conductivity. This was demonstrated in CFRP (Carbon fiber reinforced plastics) laminates. Refractive index (n) was defined as one of mechanical properties; so a method was solved in order solve the "n" in the material with the cut parts of the turbine blades of wind energy. The defects and anomalies investigated by terahertz radiation were foreign material inclusions and simulated disband. Especially, it is found that the T-ray went through the turbine blade with greater thickness (about 90mm).

A Comparative Study of Glottal Data from Normal Adults Using Two Laryngographs

  • Yang, Byung-Gon;Wang, Soo-Geun;Kwon, Soon-Bok
    • Speech Sciences
    • /
    • v.10 no.1
    • /
    • pp.15-25
    • /
    • 2003
  • A laryngograph was developed to measure the open and closed movements of vocal folds in our laboratory. This study attempted to evaluate its performance by comparing its glottal data with that of the original laryngograph. Ten normal Korean adults Participated in the experiment. Each subject produced a sustained vowel /a/ for about five seconds. This study compared f0 values, contact quotients of the duration of closed vocal folds over one glottal pulse, and area quotients of the closed over open vocal folds derived from glottal waves using both the original and new laryngographs. Results showed that the mean and standard deviation of the two laryngographs were almost comparable with a correlation coefficient 0.662 but minor systematic shift below those of the original laryngograph was observed. The absolute mean difference converged into 1 Hz, which indicates a possibility of adopting some threshold of rejecting inappropriate pitch values beyond a threshold value. The contact quotient of the normal subjects came out slightly over the 50% in a citation speech. Finally, the area quotient converged into 1. We will pursue further studies on the abnormal patients in the future.

  • PDF

Cascaded-transformer-based 3$^{n-1}$+2 level PWM Inverter (다단 변압기 기반 3$^{n-1}$+2 레벨 PWM 인버터)

  • Kang, Feel-Soon;Park, Jin-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.681-684
    • /
    • 2005
  • This paper presents a useful multilevel PWM inverter scheme based on a (3$^{n-1}$+2) level generation technique. It consists of a PWM inverter, an assembly of LEVEL inverters, and cascaded transformers. To produce high quality output voltage waves, it synthesizes a large number of output voltage levels using cascaded transformers, which have a series-connected secondary. By a suitable selection of secondary turn-ration of the transformer, the amplitude of an output voltage is appeared at the rate of an integer to an input dc source. Operational principles and analysis are illustrated in depth. The validity of the proposed system is verified through computer-aided simulations and experimental results using prototypes generation output voltages of an 11-level and a 29-level, respectively. And their results are compared with conventional counterparts.

  • PDF

One-Cycle Control Strategy for Dual-Converter Three-Phase PWM Rectifier under Unbalanced Grid Voltage Conditions

  • Xu, You;Zhang, Qingjie;Deng, Kai
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.268-277
    • /
    • 2015
  • In this paper, a dual-converter three-phase pulse width modulation (PWM) rectifier based on unbalanced one-cycle control (OCC) strategy is proposed. The proposed rectifier is used to eliminate the second harmonic waves of DC voltage and distortion of line currents under unbalanced input grid voltage conditions. The dual-converter PWM rectifier employs two converters, which are called positive-sequence converter and negative-sequence converter. The unbalanced OCC system compensates feedback currents of positive-sequence converter via grid negative-sequence voltages, as well as compensates feedback currents of negative-sequence converter via grid positive-sequence voltages. The AC currents of positive- and negative-sequence converter are controlled to be symmetrical. Thus, the workload of every switching device of converter is balanced. Only one conventional PI controller is adopted to achieve invariant power control. Then, the parameter tuning is simplified, and the extraction for positive- and negative-sequence currents is not needed anymore. The effectiveness and the viability of the control strategy are demonstrated through detailed experimental verification.

A New Random SPWM Technique for AC-AC Converter-Based WECS

  • Singh, Navdeep;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.939-950
    • /
    • 2015
  • A single-stage AC-AC converter has been designed for a wind energy conversion system (WECS) that eliminates multistage operation and DC-link filter elements, thus resolving size, weight, and reliability issues. A simple switching strategy is used to control the switches that changes the variable-frequency AC output of an electrical generator to a constant-frequency supply to feed into a distributed electrical load/grid. In addition, a modified random sinusoidal pulse width modulation (RSPWM) technique has been developed for the designed converter to make the overall system more efficient by increasing generating power capacity and reducing the effects of inter-harmonics and sub-harmonics generated in the WECS. The technique uses carrier and reference waves of variable switching frequency to calculate the firing angles of the switches of the converter so that the three-phase output voltage of the converter is very close to a sine wave with reduced THD. A comparison of the performance of the proposed RSPWM technique with the conventional SPWM demonstrated that the power generated by a turbine in the proposed approximately increased by 5% to 10% and THD reduces by 40% both in voltage and current with respect to conventional SPWM.