• Title/Summary/Keyword: Pulse Waves

Search Result 306, Processing Time 0.03 seconds

Comparisons of the Accuracy of Classification Methods in Sasang Constitution Diagnosis with Pulse Waves (맥파를 이용한 사상체질의 진단에 있어서 분류방법에 따른 진단의 정확도 비교)

  • Shin, Sang-Hoon;Kim, Jong-Yeol
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.10
    • /
    • pp.249-257
    • /
    • 2009
  • The purpose of this study is to find a classification method with high accuracy in regard with sasang constitutional diagnosis. The BMI, blood pressure, pulse wave, and Sasang constitution diagnosed by a specialist was collected from 2848 subjects who were apparently healthy. Through a selective procedure, the data of 1635 subjects was used in the analysis. The results with the classification methods such as the discriminant analysis, regression, decision tree and neural network were compared with the diagnosis of a Sasang constitutional specialist. In result, the discriminant analysis method was hard to qualify the assumption of the equality of covariance matrices within constitutional groups. Moreover, without BMI, the decision tree and neural network methods were very sensitive to the change of the analysis data. Therefore, the Logistic regression and the decision tree is recommended on condition that the decisive factors of constitution are well concerned.

A Study about Correlations between the Interpretations of Autonomic Bioelectric Response Recorder (ABR-2000) and Diagnosis System of Oriental Medicine (DSOM) / 3D Blood Pressure Pulse Analyzer (3D-MAC) (생체전기자율반응 측정기와 한방진단시스템 및 맥진기 검사 해석의 상관성 연구)

  • Ok, Jin-Yoo;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.2
    • /
    • pp.31-48
    • /
    • 2018
  • Objectives: This study was performed to observe the correlations between the results of ABR-2000 and DSOM / 3D-MAC to evaluate the feasibility of ABR-2000 as a oriental medical diagnostic criteria. Methods: We studied 547 women visiting ${\bigcirc}{\bigcirc}$ hospital from December 2012 to June 2015. The subjects were categorized in two groups, 'Hypotonia' and 'Non-Hypotonia' by the result of ABR-2000 and assessed the result of DSOM, 3D-MAC for each group. The differences of pulse wave factors by group also studied. Results: 1. There was no significant difference between two groups about the output frequency of pathogenic factors in DSOM while the result showed the higher correlation in Hypotonia group in terms of the companion tendency of pathogenic factors and syndromes formed by the combination of pathogenic factors. 2. The pulse waves of Hypotonia group were mostly slow, weak, tense and stiff than Non-Hypotonia group. Conclusions: 1. In Hypotonia group, yin deficiency (陰虛) factor was frequently accompanied and consumption (虛損) of various organs based on the yin deficiency (陰虛) was observed. It means chronic and severe condition of exhaustion syndrome (虛勞). 2. The result of 3D-MAC also means pathological feature of yin syndrome (陰 證) and consumption (虛損). Besides, lower scores of Body Surface Area (BSA), body weight, and Body Mass Index (BMI) were associated with body weakness (體瘦), a symptom of exhaustion syndrome (虛勞).

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Identification Algorithm for Up/Down Sliding PRIs of Unidentified RADAR Pulses With Enhanced Electronic Protection (우수한 전자 보호 기능을 가진 미상 레이더 펄스의 상/하 슬라이딩 PRI 식별 알고리즘)

  • Lee, Yongsik;Kim, Jinsoo;Kim, Euigyoo;Lim, Jaesung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.6
    • /
    • pp.611-619
    • /
    • 2016
  • Success in modern war depends on electronic warfare. Therefore, It is very important to identify the kind of Radar PRI modulations in a lot of Radar electromagnetic waves. In this paper, I propose an algorithm to identify Linear up Sliding PRI, Non-Linear up Sliding PRI and Linear Down Sliding PRI, Non-Linear Down Sliding PRI among many Radar pulses. We applied not only the TDOA(Time Difference Of Arrival) concept of Radar pulse signals incoming to antennas but also a rising and falling curve characteristics of those PRI's. After making a program by such algorithm, we input each 40 data to those PRI's identification programs and as a result, those programs fully processed the data in according to expectations. In the future, those programs can be applied to the ESM, ELINT system.

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

A Study on Ultrasonic Wave Propagation Model in Multi-Layer Media (다중 접착계면의 초음파 전달 모델 연구)

  • Lim, Soo-Yong;Kim, Dong-Ryun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.9-15
    • /
    • 2012
  • This research simulates the ultrasonic wave propagation in multi-layered media using generalized formular of system response function. We made the artificial defect specimen of a rocket motor and compared with experimental wave forms. The simulation results are coincide with measured waves and we found that the pulse echo method is able to detect unbond defect at liner-propellant interface.

A Study on the Characteristics of Elastic Wave Propagation in Plates Using Pulse Laser Holographic Interferometry (펄스 레이저 홀로그래픽 간섭계를 이용한 평판의 탄성파 전파 특성에 관한 연구)

  • 이기백;나종문;김정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.106-112
    • /
    • 1996
  • In this paper, the propagation of elastic wave generated by loading impact to plates made of isotropic or anisotropic material was studied. And the influence of boundary conditions(free or clamped edge) upon the reflection of elastic wave of isotropic plate such as aluminum plate showed circular interferometric fringe pattern, whereas that of anisotropic plate such as epoxy composite laminates showed elliptical one. And the transverse displacement curves obtained from experiment and theory for both plates agreed well. Also, the waves reflected from the boundary edges showed much differences according to the boundary condition of edges.

  • PDF

An Improved Carrier-based SVPWM Method By the Redistribution of Carrier-wave Using Leg Voltage Redundancies in Generalized Cascaded Multilevel Inverter

  • Kang, Dae-Wook;Lee, Yo-Han;Suh, Bum-Seok;Park, Chang-Ho;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.36-47
    • /
    • 2001
  • The carrier-based space vector pulse width modulation(SVPWM), which is considered as highly simple and efficient PWM technology, can be also used in multilevel inverters. The method was originally designed for the two-level inverter and developed to the diode clamped multilevel inverter structure. however it may be noted that it also cause bad switch utilization in cascaded multilevel inverter. This paper introduces an improved carrier-based SVPWM scheme, which is fully suitable for cascaded multilevel inverter topologies because it can achieve the optimized switch utilization through the redistribution of the triangular carrier waves considering leg voltage redundancies while having the advantages of the conventional carrier-based SVPWM. Using simulation and experimental results, the superior performance of new PWM method is shown.

  • PDF

Phase Matching of Pressure Wave in a Drop-On-Demand Inkjet Print Head (요구 적출형 잉크젯 프린트 헤드에서의 압력파 위상 정합)

  • Kim, Myong-Ki;Hwang, Jun-Young;Lee, Sang-Ho;Kang, Kyung-Tae;Kang, Heui-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.116-125
    • /
    • 2008
  • Inkjet printing technology with a drop-on-demand (DOD) inkget head technology has been recognized as one of versatile and low cost manufacturing tools in the electronics industry. Concerned with control of driving signal, however, general strategy to optimize jetting stability has not been understood well, because of the inherent complex multi-physics nature in inkjet phenomena. Motivated by this, present study investigates the effect of driving waveforms of piezoelectric head on jetting characteristics of DOD inkjet system focused on jetting stability with phase matching of pressure waves in the print head. The results show that velocities and volumes of the ink jetted droplets were linear relations with the driving signal's maximum voltage, while periodic behaviors are observed with the driving signal's pulse widths.

Phase Matching of Pressure Wave in a Drop-On-Demand Inkjet Print Head (요구 적출형 잉크젯 프린트 헤드에서의 압력파 위상 정합)

  • Kim, Myong-Ki;Hwang, Jun-Young;Lee, Sang-Ho;Kang, Kyung-Tae;Park, Mun-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1444-1449
    • /
    • 2007
  • Inkjet printing technology with a drop-on-demand (DOD) inkjet head technology has been recognized as one of versatile and low cost manufacturing tools in the electronics industry. Concerned with control of driving signal, however, general strategy to optimize jetting stability has not been understood well, because of the inherent complex multi-physics nature in inkjet phenomena. Motivated by this, present study investigates the effect of driving waveforms of piezoelectric head on jetting characteristics of DOD inkjet system focused on jetting stability with phase matching of pressure waves in the print head. The results show that velocities and volumes of the ink jetted droplets were linear relations with the driving signal's maximum voltage, while periodic behaviors are observed with the driving signal's pulse widths.

  • PDF