• Title/Summary/Keyword: Pulse Wave Transit Time

Search Result 22, Processing Time 0.036 seconds

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile (압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가)

  • Kim, Jung-Chae;Jee, Sun-Ha;Yoo, Sun-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Radial Electrical Impedance: A Potential Indicator for Noninvasive Cuffless Blood Pressure Measurement

  • Huynh, Toan Huu;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.239-244
    • /
    • 2017
  • Noninvasive, cuffless, and continuous blood pressure (BP) monitoring is essential to prevent and control hypertension. A well-known existing method for this measurement is pulse transit time (PTT), which has been investigated by many researchers as a promising approach. However, the fundamental principle of the PTT method is based on the time interval taken by a pulse wave to propagate between the proximal and distal arterial sites. Consequently, this method needs an independent system with two devices placed at two different sites, which is a problem. Even though some studies attempted to synchronize the system, it is bulky and inconvenient by contemporary standards. To find a more sensitive method to be used in a BP measurement device, this study used radial electrical bioimpedance (REB) as a potential indicator for BP determination. Only one impedance plethysmography channel at the wrist is performed for demonstrating a ubiquitous BP wearable device. The experiment was evaluated on eight healthy subjects with the ambulatory BP monitor on the upper arm as a reference. The results demonstrated the potential of the proposed method by the correlation of estimated systolic (SBP) and diastolic (DBP) BP against the reference at $0.84{\pm}0.05$ and $0.83{\pm}0.05$, respectively. REB also tracked the DBP well with a root-mean-squared-error of $7.5{\pm}1.35mmHg$.

Analysis of the Convergence Algorithm Model for Estimating Systolic and Diastolic Blood Pressure Based on Two Photoplethysmography (두 개의 광전용적맥파 기반의 수축기 혈압과 이완기 혈압 추정 융합 알고리즘 모델 분석)

  • Kim, Seon-Chil;Cho, Sung-Hyoun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.8
    • /
    • pp.53-58
    • /
    • 2019
  • Recently, product research has been continuously conducted to enhance accessibility to blood pressure measurement for the purpose of healthcare for the chronic patient. In previous studies, electrocardiogram (ECG) and photoelectric pulse wave (PPG) are analyzed to calculate systolic and diastolic blood pressure. The problem is the development of analysis algorithms for accuracy and reproducibility. In this study, in the development stage of a micro blood pressure measuring device, the size of the device was reduced and the measurement method was simplified, while the algorithm was to extract systolic blood pressure (SBP) using only two PPGs and obtain diastolic blood pressure (DBP). The difference value of PPG, DF_P, is inversely related to SBP, and has a proportional relationship with DBP, which can be leaked by algorithm, and DBP can be tracked through SBP.

Estimation of the Variation of Quantity in PWV in Accordance with the Changes of Position in Human (자세변화에 따른 PWV 변화량의 평가)

  • Jun, Suk-Hwan;Jeong, In-Cheol;Jung, Sang-O;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.129-134
    • /
    • 2009
  • The ideal method which measures a blood vessel of senility and degree of arteriosclerosis is to measure compliance of arterial and condition of blood circulation at the periphery. In these days vascular stiffness have been assessed by analyzing PTT (pulse transit time) from ECG and PPG. PTT is that between toe and finger each subject estimated through ECG and PPG signals. Two parameters, which are related to PWV, were tested with the time delay between the finger and toe. PWV is a variation of quantity which is associated with vascular stiffness. These researches which use PTT and PWV don't consider the blood vessel characteristic of an individual. In this current research, we have used with the blood vessel characteristic of an individual. That is an assessment of vascular stiffness using the variation of quantity in PWV with the changes of position in the subject. PWV variation increased as functions of the subject's age. The increase of the PWV variation parameters with age is attributed to the direct decrease of the blood vessel compliance with different position. The quantity of variation estimated by experimental results is that old age's (75.78${\pm}$7.75) case is 113.68% and young age's (26.47${\pm}$2.04) case is 85.69%. We proved and presented about estimation of vascular stiffness of possibility by this result.

Blood Pressure Estimation for Development of Wearable small Blood Pressure Monitor Fusion Algorithm Analysis (웨어러블 초소형 혈압계 개발을 위한 혈압 추정 융합 알고리즘 분석)

  • Kim, Seon-Chil;Kwon, Chan-Hoe;Park, You-rim
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.209-215
    • /
    • 2019
  • The most important personal health care in digital health care is a very important issue mainly for chronic diseases. Therefore, it is important to develop a simple wearable device for real-time health management. Existing blood pressure estimation wearable devices use PPG characteristics to analyze PTT and propose blood pressure estimation algorithms. However, the influencing factors of the algorithm such as the reproducibility of PPG, whether to apply various PTTs, and variables generated from the physical differences of the measurers are actually very complex. Therefore, in this study, the correlation between PTT, SBP, and DBP was analyzed, and it was designed to use PPG sensors for device miniaturization. The blood pressure estimation algorithm took into account differences in PPG, heart rate, and personal variables.

A compact and low-power consumable device for continuous monitoring of biosignal (소형화 및 저전력소모를 구현한 실시간 생체신호 측정기 개발)

  • Cho, Jung-Hyun;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.334-340
    • /
    • 2006
  • A compact biosignal monitoring device was developed. Electrodes for electrocardiogram (ECG) and a LED and silicon detector for photoplethysmogram (PPG) were used. A lead II type was arranged for ECG measurement and reflected light was measured at the finger tip for PPG. A single chip microprocessor (model ADuC812, Analog Device) controlled a measurement protocol and processed measured signals. PPG and ECG had a sampling rate of 300 Hz with 8-bit resolution. The maximum power consumption was 100 mW. The microprocessor computed pulse transit time (PTT) between the R-wave of ECG and the peak of PPG. To increase the resolution of PTT, analog peak detectors obtained the peaks of ECG and PPG whose interval was calculated using an internal clock cycle of 921.6 kHz. The device was designed to be operated by 3-volt battery. Biosignals can be measured for $2{\sim}3$ days continuously without the external interruptions and data is stored to an on-board memory. Our system was successfully tested with human subjects.

A Study on the Estimation of Blood Pressure Based on the Magneto-Plethysmography for Smart Healthcare (스마트 헬스케어를 위한 자계용적맥파 기반 혈압 추정에 관한 연구)

  • Lee, Seong-Su;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Byoung-Hun;Kim, Kyeoung-Seop;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.917-927
    • /
    • 2018
  • High blood pressure causes various cardiovascular diseases and is associated with mortality. Periodic self-monitoring and recording of blood pressure is very helpful in preventing the occurrence of secondary diseases caused by hypertension. However, existing cuff-type blood pressure monitors have many limitations. As an alternative of that, a method of estimating the blood pressure by measuring the velocity change of the blood flow using the photo plethysmography is widely known. However, photo plethysmography have a low correlation with blood flow. So, we will propose an algorithm for estimating blood pressure using the relationship between velocity change of blood flow measured by magnetic field instead of photo plethysmography and electrocardiogram. For this purpose, First, we analyzed the correlation between photo plethysmography and magneto plethysmography. the correlation between MPG and PPG was r = 0.9449. Second, we compared estimated blood pressure and measured blood pressure. In the four experiment each result was r = 0.5737, r = 0.7863, r = 0.5669, and r = 0.7445.