암 환자와 건강인의 심박변이도 및 맥파 특징 비교 (Comparison of Heart Rate Variability and Pulse Wave Characteristics between Cancer Patients and Healthy Subjects)

  • 김수현;염지윤;오승윤;박수정
    • 대한암한의학회지
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 2021
  • Objectives: The purpose of this study is to examine whether heart rate variability (HRV) and pulse wave of cancer patients can be used as indicators of their health status and prognosis. Methods: We retrospectively compared HRV, pulse wave and body mass index (BMI) of cancer patients and healthy individuals who visited W hospital from November of 2020 to October of 2021. Results: As a result of comparing HRV and pulse wave parameters between cancer patients and healthy subjects, among HRV indices, mean heart rate (MHR), standard deviation of normal to normal (SDNN) and total power (TP), very low frequency (VLF) showed significant differences between two groups. Cancer patients' pulse wave parameters showed more rapid and superficial than that of healthy subjects. Also, cancer patients weighed less and had lower BMI. Conclusion: For increased MHR, decreased SDNN, rapid and superficial pulse wave can be indicators of poor prognosis of cancer patients, keep monitoring HRV and pulse wave can help to manage patients efficiently.

ECG 파형과 홀소자 맥진파형으로 동시 측정한 맥파전달속도 특성 연구 (Characteristics of Pulse Wave Velocity by the Simultaneously Measured ECG Waveform and Hall Device Radial Artery Waveform)

  • 유재영;최슬기;김담비;이상석
    • 한국자기학회지
    • /
    • 제22권4호
    • /
    • pp.136-141
    • /
    • 2012
  • 본 연구에서는 집게형 맥진기와 심전도계를 이용하여 전기적인 심전도 파형과 요골동맥파형을 동시 측정하여 얻은 맥파전달속도를 분석하였다. 두 신호의 동시 측정에 의한 맥파전달속도는 평균 6 m/s의 값을 보여 주었으며, ECG 파형과 홀소자 맥진파형으로 동시 측정한 방법은 기존 방법들 보다 정확하게 맥파전달속도를 측정할 수 있는 새로운 방법임을 입증하였다. 따라서 이결과는 한방의료기기인 맥진기에서 측정된 데이터를 임상적으로 활용할 수 있음을 보인다.

'맥상(脈狀)의 환측(患側)' 취혈(取穴)과 침(鍼) 치료(治療) 경과 확인 기준으로서의 촌구맥진(寸口脈診)의 의의(意義) (Significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'The affected part of the pulse wave')

  • 심소현;강민정;김재규;백진웅
    • 대한한의학원전학회지
    • /
    • 제27권1호
    • /
    • pp.47-56
    • /
    • 2014
  • Objective : The aim of this study is to find out the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' based on the literature. Method : (1) The clear concepts of the 'unaffected part' and the 'affected part' were organized. (2) The relation between the pulse diagnosis and the acupuncture in Hwangjenaekyung was studied. (3) The indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) in Hwangjenaekyung was studied. (4) The types and changes of pulse diagnosis in Hwangjenaekyung was studied, especially based on the relation between Sambuguhu pulse diagnosis(三部九候脈診) and Chongu pulse diagnosis(寸口脈診). (5) By synthesizing these results, the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' was found. Result & Conclusion : 1. When the affected part and the unaffected part are defined, it is necessary to make clear that which one of next three definitions is used ; Firstly, 'the broad sense of definition of the affected part and the unaffected part of the symptom', which contains the pulse wave. Secondly, 'the narrow sense of definition of the affected part and the unaffected part of the symptom', without the pulse wave. And thirdly, 'the definition of the affected and the unaffected part of the pulse wave', which has the only independent standard of the pulse wave. 2. Geo acupuncture treatment(巨刺法) is an acupuncture treatment which means the needling on 'the affected part of the pulse wave' based on Sambuguhu pulse diagnosis (三部九候脈診), and Mu acupuncture treatment(繆刺法) is an acupuncture treatment which means the needling on 'the unaffected part of the symptom based on the narrow sense of the definition'. The range of the indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) contains most of the diseases which contains Rakbyung(絡病), Kyungbyung(經病) and Ojangbyung(五臟病). 3. Chongu pulse diagnosis(寸口脈診) contains not only the range of the indications of Sambuguhu pulse diagnosis(三部九候脈診), but also most of the diseases. 4. From synthesizing these results of the study on the literature, we infer that Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' is significant.

토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화 (AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry)

  • 조정희;전영주;전민호;김영민
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의 (The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance)

  • 박영배;이호재;허웅
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

적혈구 용적이 요골 동맥의 맥파에 미치는 영향 (Effect of Hematocrit Level on the Radial Pulse Wave)

  • 유현희;전영주;김재욱;이혜정;우영재;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

미출산 여성과 출산 여성의 맥파 비교 - 난임 맥파 지표 연구를 위한 - (A Study on the Pulse Wave Parameter in Non Delivery and Delivery Women)

  • 서창운;김경철;김이순
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.200-215
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the differences of pulse wave parameter between the non delivery group (single women with no childbirth experience) and the delivery group (married women who gave birth(s) in delivery). Methods : Sixty one healthy (non delivery) nulliparous women and fifty three delivery women participated in this study. We used 3 dimensional pulse analyser(3D MAC, DAEYOMEDI co., Korea), which measures radial pulse waveform non-invasively by way of tonometry method at 5 different applied pressure levels. From 114 subjects enrolled, pulse wave parameters were measured on the six locations of Chon, Kwan and Cheok of each hands. Results : Delivery group's pulse showed larger values in the following pulse wave parameters (Energy, Ap, RAI, As, Aw, h1, h2, h4, h4/h1, t, t1, t2, t4, Wm, Wm/t). Non delivery group's pulse indicated larger values in the pulse wave parameters such as Energy of left Chon, difference pulse energy between left and right hand, Ad, h5, h5/h1, t5. Conclusions : According to the analysis result, delivery group's pulse has bigger values in most part of pulse wave parameters, especially in Kwan and Cheok which correspond to Liver, Kidney, and Myeong-mun. We interpret these results that delivery women are more mature and stable in reproductive organs than non delivery group, as they have experienced delivery(deliveries) and child-caring through married life.

A Vascular Characteristic Index of Blood Pressure Variation using the Pulse Wave Signal

  • Kim, Gi-Ryon;Jung, Dong-Keun;Ye, Soo-Young;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.213-219
    • /
    • 2008
  • Pulse waves continuously change with respect to the characteristics and status of the cardiovascular system and in relation to the blood pressure (BP) and the pulse wave velocity (PWV). Monitoring the vascular condition by analyzing the variations in pulse waveforms has been used to diagnose vascular disorders and in drug treatment of arteriosclerosis and peripheral circulatory obstruction. In this paper, we investigated the vascular characteristic index with regard to the BP and classified by pulse wave signals. The pressure pulse wave and photoplethysmography (PPG) were measured simultaneously while subjects exercised, producing changes in the BP, to analyze the variation in the vascular characteristic index. We investigated the correlation between the BP and vascular characteristic index with regard to the classification methods of the pulse wave. The reflection index (RI) and vascular stiffness index were correlated with the diastolic BP, but no correlation was found between these parameters and the systolic BP. These results suggest the possibility of estimating BP through simple measurements of pulse waves.

공압 방식에 의한 다지점 요골 맥파 검출 장치 (Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System)

  • 이종진;정민석;황성하;이종현;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF

무선 기반의 광섬유 간섭계형 맥파센서 시스템 (Wireless Optical Fiber Interferometer Arterial Pulse Wave Sensor System)

  • 박재희;신종덕
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.439-443
    • /
    • 2013
  • A wireless optical fiber interferometer arterial pulse wave sensor system is developed for remote sensing. The wireless optical fiber sensor system consists of Zigbee communication modules and an optical fiber interferometer arterial pulse wave sensor. The optical fiber arterial pulse wave sensor is an in-line Michelson interferometer enclosed with steel reinforcement in a heat-shrinkable tube. The Zigbee communication modules are composed of an ATmega128L microprocessor and a CC2420 Zigbee chip. The arterial pulse waves detected by the optical fiber sensor were transmitted and received via the Zigbee communication modules. The experimental results show that the wireless optical fiber sensor system can be used for monitoring the arterial pulse waves remotely.