• 제목/요약/키워드: Pulse Wave

검색결과 1,040건 처리시간 0.027초

요추부 추간판 탈출증 환자에 대한 고전압 미세전류치료의 누적치료효과 (Cumulative Therapeutic Effect of High-Voltage Microcurrent Therapy in Patients with Herniated Lumbar Disc)

  • 윤왕현;박진영;김도영;박중현
    • Clinical Pain
    • /
    • 제18권2호
    • /
    • pp.65-69
    • /
    • 2019
  • Objective: This study aims to evaluate the efficacy of high-voltage microcurrent therapy in patients with herniated lumbar disc (HLD) presenting radicular or back pain. Method: This is a retrospective study with 33 patients who are complaining pain with HLD findings on magnetic resonance image. Microcurrent therapy was applied to leg or paralumbar area. Treatment was conducted for seven minutes with 250~1000 uA intensity as high as the patients could tolerate via stimulating probe with roller type and the frequency was 60 Hz with a sine wave pulse. The visual analogue scale (VAS) was measured just before and after the treatment. Results: The degree of pain reduction (△VAS) was 1.6 points after treatment on average. The △VAS according to the diagnosis, stenosis, dermatome area, medication, pain site and caudal epidural block was not statistically significant. However, the △VAS according to the number of treatments (< 3, ≥ 3 times) showed a statistically significant difference (p=0.04). Conclusion: High-voltage microcurrent therapy may help reduce lumbar or lumbosacral radiating pain after the procedure. The effect was better when microcurrent was applied three times or more. This result suggests that the microcurrent would have cumulative effect on reducing radicular or back pain in patients with HLD.

1.29 GHz 펄스파로 산출한 대기경계층 고도 (Atmospheric Boundary Layer Height Estimated based on 1.29 GHz Pulse Wave)

  • 서지우;권병혁;이경훈;이건명
    • 한국전자통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1049-1056
    • /
    • 2023
  • 대기경계층 고도는 지면의 가열로 인해 발생한 난류가 경계층 내의 열, 수증기 등을 혼합하면서 생성되는 꼭대기로 일반적으로 열역학적 방법을 통해 결정한다. 윈드프로파일러는 대기 중으로 보낸 신호의 산란 정보로 대기의 정보를 산출한다. 윈드프로파일러 관측으로 대기경계층 깊이를 결정하기 위해 난류 성분의 스펙트럼 및 난류운동에너지 소산율, 굴절지수구조계수를 산출하는 방법을 제시하였다. 라디오존데 자료를 기반으로 산출한 온위와 비습의 연직 분포 특징과 비교하여 윈드프로파일러 산출물 기반의 대기경계층 고도 결정 방법이 매우 유용한 것으로 평가되었다.

산림치유 프로그램이 중년 여성의 스트레스 저감에 미치는 영향 (The Effect of Forest Therapy Program on Stress Reduction in Middle-aged Women)

  • 정용구;신원섭
    • 한국환경생태학회지
    • /
    • 제37권6호
    • /
    • pp.464-472
    • /
    • 2023
  • 중년여성은 발달주기 상 신체적, 정신적 스트레스를 많이 받는 시기이다. 이러한 스트레스는 만성적인 고통과 질병으로 연결되기 때문에 삶의 질을 저하시키는 원인이 된다. 이에 대한 대안으로 산림치유가 주목받고 있다. 산림치유는 산림의 치유적 요소를 통해 인간의 건강을 향상시키는 것을 말한다. 이에 본 연구는 감각통찰기반 산림치유 프로그램이 중년 여성의 스트레스 저감에 효과가 있는지를 확인하기 위하여 수행되었다. 이를 위해 산림치유 프로그램에 참가하기를 원하는 중년 여성을 모집하여 실험집단과 통제집단으로 각 20명씩 무작위 배정하여 사전-사후 검사를 실시하였다. 산림치유 프로그램은 감각과 통찰 기반으로 6시간 8회기로 구성되었다. 산림치유 프로그램 장소는 제주 사려니숲에서 진행하였으며, 측정도구는 지각된 스트레스, 여가만족도, 맥파검사를 통한 스트레스 지수를 측정하여 비교하였다. 연구 결과 산림치유 프로그램은 스트레스를 낮추고, 여가만족도를 향상시키는 것으로 나타났다.

비만 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구 (Pulse wave velocity and ankle brachial index in obese adolescents)

  • 김지혜;구희선;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제50권11호
    • /
    • pp.1078-1084
    • /
    • 2007
  • 목 적 : 맥파 속도는 동맥 경직도를 측정할 수 있는 유용하고 비침습적인 방법이다. 비만은 여러 가지 기전에 의하여 동맥 경직도를 증가시킨다고 알려졌다. 그러나 소아 비만에서 맥파 속도에 대한 연구는 매우 적은 실정이다. 저자들은 비만 청소년에서 비만이 맥파 속도와 발목 상완 지수에 미치는 영향을 알아보고자 본 연구를 실시하였다. 방 법 : 1군은 15-16세 사이의 체질량지수가 85-95 백분위수 사이인 비만 위험군 청소년 40명(남자 22명, 여자 18명)으로 하였고, 2군은 체질량지수가 95백분위수 이상인 비만 청소년 39명(남자 26명, 여자 13명)을 대상으로 하였다. 정상 청소년 99명(남자 54명, 여자 45명)을 대조군으로 하였다. 신장, 체중을 이용하여 체질량지수를 산출하였고, VP-1000 기기(Colin Medical Technology Company, Komaki, Japan)를 이용하여 사지 수축기, 이완기, 평균 혈압, 양측 맥파 속도, 발목-상완 동맥압 지수, 박출 시간, 전구출기를 측정 후 비교 분석하였다. 체질량지수와 좌우 상완-발목 맥파 속도, 발목-상완 동맥압 지수, 혈압을 비교 분석하였고, 각 변수 간의 상관성을 연구하였다. 결 과 : 우상완-발목 맥파 속도는 1군(944.8 cm/sec)이나 3군(941.0 cm/sec)에 비하여 2군(1,012.8 cm/sec)에서 유의하게 높은 값을 보여 주었고, 좌상완-발목 맥파 속도도 2군(1,015.3 cm/ sec)에서 1군(940.1 cm/sec)이나 3군(942.2 cm/sec)에 비해 유의하게 높은 값을 보였다. 발목-상완 동맥압 지수, 심박동수, 전구출기/박동 시간 값은 각 군 간에 유의한 차이가 없었다. 상완-발목 맥파 속도와 혈압은 체질량지수가 증가할수록 증가하는 양의 상관관계를 보였으나 발목-상완 동맥압 지수는 체중, 신장, 체질량지수 어느 것과도 유의한 상관관계가 없었다. 결 론 : 체질량지수가 증가함에 따라 맥파 속도가 증가하는 점을 볼 때, 비만이 동맥 경직도의 증가와 밀접한 연관성이 있음을 알 수 있었다. 맥파 속도를 이용하여 청소년의 비만군 및 위험군을 조기에 발견하여 관리하는 것이 성인기에 심혈관 질환으로 이환되는 것을 예방하는 데 도움이 되리라 생각한다.

고혈압 청소년의 심혈관계 위험요소로서 Angiotensinogen M235T 유전자 다형 (Angiotensinogen gene M235T polymorphism as a predictor of cardiovascular risk in hypertensive adolescents)

  • 길주현;이정아;박은영;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제52권1호
    • /
    • pp.36-43
    • /
    • 2009
  • 목 적 : 레닌-안지오텐신계가 혈압 조절에 있어서 핵심적인 역할을 한다는 것은 이미 잘 알려진 사실이며, 이 체계의 한 구성 요소인 angiotensinogen을 암호화하는 유전자가 고혈압의 유전적 감수성을 결정하고 심혈관계 합병증 발생에 중요한 역할을 할 것으로 생각된다. 본 연구의 목적은 고혈압 청소년에서 angiotensinogen 유전자 다형을 분석하고, 특정 유전자형이 심혈관계 합병증의 예측 인자가 될 수 있는지를 알아보고자 하였다. 방 법 : 16세에서 17세 사이의 수축기 혈압 140 mmHg 이상이거나 이완기 혈압 90 mmHg 이상인 40명의 고혈압 청소년과 57명의 정상 청소년을 대상으로 하였다. 비만도, 체질량지수를 측정하였고, 안정된 상태에서 수축기, 이완기 혈압을 측정하였다. 호모시스테인, 인슐린, 레닌, 알도스테론, 안지오텐신 전환 효소(angiotensin convering enzyme, ACE)를 측정하였고, polymerase chain reaction (PCR)을 이용하여 angiotensinogen (M235T) 유전자형을 분석하였다. 경부 초음파로 경동맥 내중막 두께와 경동맥 직경을 측정하였고, 이를 이용하여 경동맥의 유순도와 신전도를 구하였다. VP-1000을 이용하여 pulse wave velocity (PWV)와 ankle-brachial index (ABI)를 측정하였다. 유전자 다형별로 각 계측치를 비교, 분석하였다. 결 과 : Angiotensinogen 유전자 다형 분석에서 T/T 군 25명(62.5%), M/T 군 14명(35%), M/M 군 1명(2.5%)로 정상 청소년과 유의한 빈도의 차이가 없었다. 고혈압군에서 인슐린, 레닌, 체질량지수, 비만도에서 세 유전형군 간의 유의한 차이가 나타났으나, 경동맥 내중막 두께와 직경, 신전도, 유순도, PWV, ABI에서는 세군 간의 유의한 차이는 없었다. 결 론 : Angiotensinogen의 특정 유전자 다형과 심혈관계 합병증간의 유의한 연관성은 없었으나, 본 연구의 고혈압 청소년 대상이 적었으므로 더 많은 연구가 필요할 것으로 생각된다.

초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법 (Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System)

  • 정영관;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권1호
    • /
    • pp.49-60
    • /
    • 2002
  • 본 논문에서는 프레임율의 저하없이 개선된 해상도를 얻을 수 있는 동시 다중 송신집속 기법을 제안한다. 제안한 기법은 짧은 펄스를 사용하여 한 영역에 고정 송신 집속하는 기존의 방법과는 달리 여러 송신 집속점에 서로 독립적으로 집속된 쳐프 신호들을 동시에 송신한다. 수신된 신호는 정합 과정을 통하여 송신 집속 위치에 따라 각 쳐프 신호로 분리되고 짧은 펄스로 압축된다. 이렇게 압축되고 분리된 신호들은 각각 수신 동적 집속된 후 거리에 따라 집속 위치별로 선택되고 하나의 신호로 결합되어 개선된 측방향 해상도의 영상을 구성한다. 송신시 동시에 여러 위치에 초음파를 집속하고 수신시 이를 분리하기 위해서 사용된 터프 신호들은 주파수 대역에서 분할되어 서로 직교 특성을 갖도록 설계되었는데 변환자의 제한된 대역폭내에 많은 수의 의미있는 쳐프 신호를 설계하기 위해서 인접한 두 쳐프 신호의 주파수 대역 겹침을 허용하였다. 이때 대역 겹침으로 발생한 상호상관값의 상승을 억제하기 위해 인접한 두 쳐프 신호의 주파수 변화 방향을 엇갈리게 하는 밥법을 제안하였다. 특히 대역분할로 설계된 쳐프 신호중 낮은 주파수 성분의 신호를 변환자로부터 가까운 지역에 집속하고 높은 주파수 성분의 쳐프 신호를 먼 지역에 집속함으로써 깊이에 따라 영상의 해상도의 질을 일정하게 유지시켰다 더욱이 상관기를 이용한 정합 과정에서 신호가 압축되기 때문에 펄스 압축 기법에서 얻는 SNR를 증가시키는 이점이 있다 이때 상관기를 통한 압축 과정에서 쳐프 신호의 첨두값이 쳐프 신호의 길이에 따라 증가하기 때문에 깊이에 따를 높은 주파수 성분의 감쇄에도 불구하고 이렇게 높은 주파수 성분의 터프 신호를 깊은 지역에 사용할 수 있었다. 제안한 동시 다중 송신집속 기반의 시스템을 상관기의 위치에 따라 이상적인 구조와 현실적인 구조로 나타냈으며, 모사 실험을 통하여 기존의 펄스 집속 기법과 비교하여 그 성능을 검증하였다.hrough the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$). public transportation, and availability of locally grown food were the important factors for deciding the place compared to those who had higher education. The price was the factor which

지역사회 거주 50세 이상 성인의 동맥경직도와 염증반응인자와의 관련성 (Cross-Sectional Relations of Arterial Stiffness and Inflammatory Markers in Korean Adults Aged 50 Years and Older)

  • 류소연;신민호;이영훈;이정애;최진수;박경수;남해성;정슬기;권순석
    • 농촌의학ㆍ지역보건
    • /
    • 제36권2호
    • /
    • pp.101-112
    • /
    • 2011
  • 50세 이상 건강한 성인을 대상으로 baPWV로 측정한 동맥경직도 수준과 염증인자와 동맥경직도와의 관련성을 파악하기 위하여 본 연구를 수행하였다. 2007년과 2008년에 수행된 광주광역시 동구연구(Dong-gu Study)의 기반조사에 참여한 50세 이상 주민 4617명을 대상으로 하였으며, 다중회귀분석을 시행하여 전통적인 심뇌혈관질환 위험요인을 통제한 상태에서 baPWV와 CRP, GGT와 WBC 등의 염증반응인자와의 관련성을 알아보았다. 평균 baPWV는 남자 $17.0{\pm}4.0\;m/s$, 여자 $16.2{\pm}3.6\;m/s$로 남, 여 간에 통계적으로 유의한 차이가 있었고, 연령이 증가할수록 baPWV는 통계적으로 유의하게 증가하는 경향을 보였다. 성, 연령, 흡연상태, 체질량지수, 수축기혈압, 공복혈당, 고혈압 또는 당뇨병의 투약 여부, 혈청 지질, 요산과 ALT 등의 전통적인 심뇌혈관질환 위험요인을 통제한 상태에서 WBC (${\beta}$=0.158, p<0.0001), hs-CRP(${\beta}$=0.244, p=0.026)와 GGT (${\beta}$=0.003, p<0.0001)는 baPWV와 통계적으로 유의하게 독립적인 관련성이 있음을 알 수 있었다. 결론적으로 baPWV로 측정한 동맥경직도 지표는 염증반응인자와 관련이 있음을 알 수 있었다. baPWV 등의 동맥경직도 측정 지표는 동맥 기능의 초기변화를 반영하고 일반적으로 알려져 있는 심혈관질환 위험요인과 유의한 상관관계를 가지고 있어, 이를 이용하여 심혈관질환의 위험을 예측하는데 활용할 수 있을 것으로 생각된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법 (Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach)

  • 김강식;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.391-401
    • /
    • 2004
  • 이차원 위상 어레이 변환자를 이용하는 실시간 3차원 영상 시스템은 많은 수의 채널 수를 가지기 때문에 고 비용의 매우 복잡한 빔집속부를 사용하여야 한다. 또한 각 주사선에 대해 초음파를 매번 송수신해야 하므로 볼륨 레이트 또한 낮게 된다. 이를 해결하기 위해 기존에 제안된 교차어레이를 이용한 3차원 영상화 기법은 실시간 3차원 영상을 위한 고속 주사가 가능하고 측방향으로는 동적집속이 가능하지만, 고도방향으로는 송신집속깊이를 제외하고는 고도방향의 해상도가 저하된다는 문제점이 있다. 이러한 문제점을 극복하기 위해 본 논문에서는 합성구경 기반의 교차 어레이를 사용한 3차원 영상화 기법을 제안한다. 제안한 방법에서는 고도방향으로 놓인 일차원 송신어레이의 각 변환소자를 한번에 하나씩 순차적으로 송신하고, 반사된 신호들을 측방향으로 놓인 일차원 수신어레이의 모든 변환소자를 이용하여 수신하게 된다. 수신시 측방향으로는 동적집속, 고도방향으로는 합성구경 기법을 이용하여 빔을 집속함으로써 모든 영상 점에 대해 측방향과 고도방향 모두 동적집속된 효과를 얻을 수 있다. 또한, 제안한 방법은 고도방향으로 합성구경 기법을 이용함으로써 송신어레이 변화소자 개수만큼의 초음파 송수신 과정을 통해 관심 영역의 입제영상을 임의의 요구되는 단면영상 수를 이용하여 구성할 수 있다. 제안한 방법을 통해 기존의 고정집속 기반의 교차어레이를 이용한 3차원 영상화 기법과 비교하여 측방향으로는 동일하고 고도방향으로는 훨씬 우수한 해상도의 영상을 획득할 수 있음을 컴퓨터 모사실험을 통해 점증하였다. 또한 동반논문에서는 제안한 방법에 비해 송신전력과 고도방향 해상도를 더욱 향상시킬 수 있는 선형파면 기반의 합성구경 기법을 제안한다.