• Title/Summary/Keyword: Pulse Sequence

Search Result 308, Processing Time 0.024 seconds

Cerebral Activation Area Following Oxygen Administration using a 3 Tesla Functional MR Imaging (고 자장 기능적 MR 영상을 이용한 뇌 운동 영역에서 산소 주입에 따른 활성화 영역에 관한 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.47-53
    • /
    • 2005
  • This study aim to investigate the effects of supply of oxygen enhances cerebral activation through increased activation in the brain and using a 3 Tesla fMRI system. Five volunteers (right handed, average age of 21.3) were selected as subjects for this study. Oxygen supply equipment that provides 30% oxygen at a constant rate of 15L/min was given using face mask. A 3 Tesla fMRI system using the EPI BOLD technique, and three-pulse sequence technique get of the true axial planes scanned brain images. The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers. Complex movement consisted of a finger task in which subjects flexed and extended all fingers repeatedly in union, without the fingers touching each other. Both task consisted of 96 phases including 6 activations and rests contents. Post-processing was done on MRDx software program by using cross-correlation method. The result shows that there was an improvement in performance and also increased activation in several areas in the oxygen method. These finding demonstrates that while performing cognitive tasks, oxygen administration was due to increase of cerebral activation.

Characteristic of Induction Motor Drives Fed by Three Leg and Five Leg Inverters

  • Talib, Md. Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Hasim, Ahmad Shukri Abu
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.806-813
    • /
    • 2013
  • This paper aims to compare the performance of three phase induction motor drives using Five Leg Inverter (FLI) and Three Leg Inverter (TLI) configurations. An Indirect Field Oriented Control (IFOC) method using a TLI is well established and incorporated for high performance speed drives in various industries. The FLI dual motor drive system on the other hand shows good workability in the independent control of two induction motor drives simultaneously. In this experiment, the IFOC method is utilized for both drive systems, and Space Vector Pulse Width Modulation (SVPWM) is used to generate pulses for both inverters. For the FLI, the Double Zero Sequence (DZS) Injection technique is used to generate the modulation signal. The complete experiment setup is done by using a DSpace 1103 controller board. The individual motor performances are analyzed using similar schemes, equipment setups and controller parameter values. The results show similar speed performance response capability between the single motor operation using a TLI system and the two motor operation using a FLI system based on the variable speed range either in forward or reverse operation. They also show similar load rejection abilities. However, the single motor with a TLI has a better power quality aspect such as ripple current and total harmonics distortion (THD).

Gradient Optimized Gradient-Echo Gradient Moment Nulling Sequences for Flow Compensation of Brain Images

  • Jahng, Geon-Ho;Stephen Pickup
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • Gradient moment nulling techniques require the introduction of an additional gradient on each axis for each order of motion correction to be applied. The additional gradients introduce new constraints on the sequence design and increase the demands on the gradient system. The purpose of this paper is to demonstrate techniques for optimization of gradient echo gradient moment nulling sequences within the constraints of the gradient hardware. Flow compensated pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. The design of the gradient moment nulling sequences requires the solution of a linear system of equations. A Mathematica package was developed that interactively solves the gradient moment nulling problem. The package allows the physicist to specify the desired order of motion compensation and the duration of the gradients in the sequence with different gradient envelopes. The gradient echo sequences with first, second, and third order motion compensation were implemented with minimum echo time. The sequences were optimized to take full advantage of the capabilities of the gradient hardware. The sequences were used to generate images of phantoms and human brains. The optimized sequences were found to have better motion compensation than comparable standard sequences.

  • PDF

Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction (회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법)

  • Chung, S.T.;Park, S.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF

Mode Transfer Sequence and Control of Single-phase UPS System (단상 UPS 시스템의 모드 절환 시퀀스 및 제어)

  • Lee, Sang-Suk;Lee, Soon-Ryung;Choi, Bong-Yeon;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.108-115
    • /
    • 2014
  • Recently, Uninterruptible power supply(UPS) is spotlighted from concern about black out, due to reserve power problem caused by increased power consumption. When fault occurs on the grid, UPS system supplies power to loads instead of the grid. Also, it is an advantage of possible operation as Energy storage system(ESS). Bi-directional power control of AC/DC Pulse width modulation(PWM) converter is essential for grid-connected UPS system. And, mode transfer control has to be performed considering phase and dynamic characteristic under grid condition. In this paper, control of mode transfer and bi-directional power control of AC/DC PWM converter is proposed for UPS system. Also, it is verified by simulation and experimental results.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

Turbo FLASH NRI Using Optimized Flip Angle Pattern: Application to Inversion-Recovery T1-Weighted Imaging (최적화된 Flip Angle Pattern을 사용한 Turbo FLASH MRI: Inversion-Recovery T1-Weighted Imaging에의 응용)

  • Oh, C.H.;Choi, H.J.;Yang, Y.J.;Lee, D.R.;Ryu, Y.C.;Hyun, J.H.;Kim, S.R.;Yi, Y.;Jung, K.J.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.55-56
    • /
    • 1998
  • The 3-D Fast Gradient Echo (Turbo FLASH, Turbo Fast Low Angle Shot) sequence is optimized to achieve a good T1 contrast using variable excitation flip angles. In Turbo FLASH sequence, depending on the contrast preparation scheme, various types of image contrast can be established. While proton density contrast is obtained when using a short repetition time with a short echo time and small flip angles, T1 or T2 weighting can be obtained with proper contrast preparation sequences applied before the above proton density Turbo FLASH sequence. To maximize the contrast to noise ratio while retaining a sharp impulse response (smooth frequency domain response), the excitation flip-angle pattern is optimized through simulation and experiments. The TI (the delay after the preparation sequence which is a 180 degree inversion RF pulse in the IR T1 weighted imaging case), TD (the delay time between the Turbo FLASH sequence and the next preparation), and TR are also optimized fur the best image quality. The proposed 3-D Turbo FLASH provides $1mm\times1mm\times1.5mm$ high resolution images within a reasonable 5-8 minutes of imaging time. The proposed imaging sequence has been implemented in a Medison's Magnum 1.0T system and verified through simulations as well as human volunteer imaging. The experimental results show the utility of the proposed method.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Flow Effects on Tailored RF Gradient Echo (TRFGE) Magnetic Resonance Imaging : In-flow and In-Plane Flow Effect (Tailored RF 경자사계방향 (TRFGE} 자기공명영상(MRI)에서 유체에 의한 영상신호 변화 : 유체유입효과와 영상면내를 흐르는 유체의 효과에 대하여)

  • Mun, Chi-Ung;Kim, Sang-Tae;No, Yong-Man;Im, Tae-Hwan;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.243-251
    • /
    • 1997
  • In this paper, we have reported two interesting flow effects arising in the TRFGE sequence using water flow phantom. First, we have shown that the TRFGE sequence is indeed not affected by "in-flow" effect from the unsaturated spins flowing into the imaging slice. Second, the enhancement of "in-plane flow" signal in the readout gradient direction was observed when the TRFGE sequence was used without flow compensation. These two results have many interesting applications in MR imaging other than fMRI. Results obtained were also compared with the results obtained by the conventional gradient echo(CGE) imaging. Experiments were performed at 4.7T MRI/S animal system (Biospec, BRUKER, Switzerland). A cylindrical phantom was made using acryl and a vinyl tube was inserted at the center(Fig. 1). The whole cylinder was filled with water doped with $MnCl_2$ and the center tube was filled with saline which flows in parallel to the main magnetic field along the tube. Tailored RF pulse was designed to have quadratic ($z^2$) phase distribution in slice direction(z). Imaging parameters were TR/TE = 55~85/10msec, flip angle = $30^{\circ}$, slice thickness = 2mm, matrix size = 256${\times}$256, and FOV= 10cm. In-flow effect : Axial images were obtained with and without flow using the CGE and TRFGE sequences, respectively. The flow direction was perpendicular to the image slice. In-plane flow : Sagittal images were obtained with and without flow using the TRGE sequence. The readout gradient was applied in parallel to the flow direction. We have observed that the "in-flow" effect did not affect the TRFGE image, while "in-plane flow" running along the readout gradient direction enhanced the signal in the TRFGE sequence when flow compensation gradient scheme was not used.

  • PDF

An Overmodulation Strategy for SVPWM Inverter Using Pole Voltage (폴전압을 이용한 SVPWM 인버터의 과변조 기법)

  • 韓 大 雄;金 相 勳
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.149-157
    • /
    • 2002
  • In this paper, a novel overmodulation strategy for space-vector PWM(SVPWM) inverters to utilize dc link voltage fully Is presented. The proposed strategy uses the concept of SVPWM based on the zero sequence signal(offset voltage) injection principle. So, by modifying the pole voltage simply, the linear control of inverter output voltage over the whole overmodulation range can be achieved easily The proposed strategy is so simple that its practical implementation is easy. The validity of the proposed strategy is confirmed by the experimental results.