• Title/Summary/Keyword: Pulse Sequence

Search Result 308, Processing Time 0.037 seconds

Improvement of SNR in DANTE Fast MR Imaging (MR DANTE 고속 영상에서 SNR의 개선에 관한 연구)

  • 정성택
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

Design of a New PN Sequence Waveform for Spread Spectrum Communication (대역 확산 통신에 쓰이는 새로운 PN 시퀀스 파형의 설계)

  • 김발기;은종관
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.4
    • /
    • pp.61-66
    • /
    • 1983
  • This paper is concerned with the design of a pseudonoise (PN) sequence used in direct-sequence spread spectrum multiple-access (DS/SSMA) communication systems. Here we propose a new waveform, a generalized version of rectangular waveform, which can reduce the multiple access interference to zero as the pulse width becomes narrower. It gives far better performance than either rectangular or sine waveform.

  • PDF

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • ;Prasad N.Enjeti
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

Hybrid Fuzzy PI-Control Scheme for Quasi Multi-Pulse Interline Power Flow Controllers Including the P-Q Decoupling Feature

  • Vural, Ahmet Mete;Bayindir, Kamil Cagatay
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.787-799
    • /
    • 2012
  • Real and reactive power flows on a transmission line interact inherently. This situation degrades power flow controller performance when independent real and reactive power flow regulation is required. In this study, a quasi multi-pulse interline power flow controller (IPFC), consisting of eight six-pulse voltage source converters (VSC) switched at the fundamental frequency is proposed to control real and reactive power flows dynamically on a transmission line in response to a sequence of set-point changes formed by unit-step reference values. It is shown that the proposed hybrid fuzzy-PI commanded IPFC shows better decoupling performance than the parameter optimized PI controllers with analytically calculated feed-forward gains for decoupling. Comparative simulation studies are carried out on a 4-machine 4-bus test power system through a number of case studies. While only the fuzzy inference of the proposed control scheme has been modeled in MATLAB, the power system, converter power circuit, control and calculation blocks have been simulated in PSCAD/EMTDC by interfacing these two packages on-line.

A Study on Color Control in Gas Discharge Tube (기체 방전관의색상 제어에 관한 연구)

  • Lee, Jong-Chan;Aono, Masaharu;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.285-288
    • /
    • 1996
  • The electronic operation of the gas discharge tube is controlled by the electrical energy as sinusoidal waveform in arbitrary frequency range, or as a sequence of pulses at a wide range of duty cycle, the gas composition, the kind of electrode and the vessel geometry. In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of IIg-Ne ( 10 Torr ), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency and pulse width in high voltage. As increasing pulse width and frequency in the gas discharge tube, the phenomenons that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist. The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing pulse width and frequency. The changing method of pulse width and frequency has been shown to be suitable for the luminous color control.

  • PDF

Research on Discontinuous Pulse Width Modulation Algorithm for Single-phase Voltage Source Rectifier

  • Yang, Xi-Jun;Qu, Hao;Tang, Hou-Jun;Yao, Chen;Zhang, Ning-Yun;Blaabjerg, Frede
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.433-445
    • /
    • 2014
  • Single phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). As the fundamental part of large scale PECs, single-phase VSC has a wide range of applications. In the paper, as first, on the basis of the concept of the discontinuous pulse-width modulation (DPWM) for three-phase VSC, a new DPWM of single-phase VSR is presented by means of zero-sequence component injection. Then, the transformation from stationary frame (abc) to rotating frame (dq) is designed after reconstructing the other orthogonal current by means of one order all-pass filter. Finally, the presented DPWM based single-phase VSR is established analyzed and simulated by means of MATLAB/SIMULINK. In addition, the DPWMs presented by D. Grahame Holmes and Thomas Lipo are discussed and simulated in brief. Obviously, the presented DPWM can also be used for single-phase VSI, GCI and APF. The simulation results show the validation of the above modulation algorithm, and the DPWM based single-phase VSR has reduced power loss and increased efficiency.

Analysis of Inflow and Susceptibility Effects in fMRI Obtained by CGE and TRFGE Techniques (CGE와 TRFGE 기법으로 얻은 뇌기능 영상에서 혈류효과와 자화율 효과의 해석)

  • No, Yong-Man;Jeong, Sun-Cheol;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.431-438
    • /
    • 1995
  • Functional imaging based on the susceptibility only is achieved by separation of the susceptibility effect from the mixture of flow effect by use of a tailored RF pulse in conjunction with gradient echo sequence. Using the tailored RF pulse the susceptibility enhanced functional imaging appears to be explicitly related to the deoxygenation processes, while in the conventional gradient echo technique functional contrast on $T2^{*}$ effect images appear to be mixed with a significant fraction of blood flow (in- flow) signals of both arterial as well as venous bloods due to the nature of the fast sequence employed with the gradient echo technique. In this paper, using the tailored RF pulses, one can unambiguously separate the susceptibility and flow effects in functional imaging. Since the signal obtained can be made sufficiently high and represents oxygenation process more accurately, it seems possible to study quantitative oxygen metabolisms in brain function hitherto difficult to do with other gradient echo techniques.

  • PDF

Performance Analysis of BPM UWB Multiple Access System Using PN Code Based Time Hopping Sequence in Indoor Wireless Channels (실내 무선 환경에서 PN 부호 기반 시간 도약 시퀀스를 이용하는 BPM UWB 다원 접속 시스템의 성능 분석)

  • 양석철;신요안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.187-198
    • /
    • 2004
  • In this paper, we analyze the performance of BPM (Bi-Phase Modulation) UWB (Ultra Wide Band) multiple access system using PN (Pseudo Noise) code based time hopping sequence in indoor wireless channels. In particular, we compare BPM UWB multiple access system with PPM (Pulse Position Modulation) UWB multiple access system in terms of signalling and demodulation schemes. Moreover, we analytically evaluate the performance of these UWB systems by deriving the bit error rate expressions under the assumption that pulse energy and data transmission rate are identical for both systems. Simulation results in additive white Gaussian noise and realistic indoor multipath wireless channels show that the performance of BPM scheme is approximately 1 dB better than that of PPM scheme. However, the performance discrepancy becomes negligible as the number of users increases.

Performance Analysis of Clock Recovery for OFDM/QPSK-DMR System Using Band Limited-Pulse Shaping Filter (대역 제한 필터를 이용하는 OFDM/QPSK-DMR 시스템을 위한 클럭 복조기의 성능 분석)

  • 안준배;양희진;강희곡;오창헌;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.245-249
    • /
    • 2004
  • In this paper, we have proposed a clock recovery algorithm of Orthogonal Frequency Division Multiplexing/Quadrature Phase Shift Keying Modulation-Digital Microwave Radio(OFDM/QPSK-DMR) system using Band Limited-Pulse Shaping Filter(BL-PSF) and compared the clock phase error variance of OFDM/QPSK-DMR system with that of single carrier DMR system. The OFDM/QPSK-DMR system using windowing method requires training sequence or Cyclic Prefix (CP) to synchronize the clock phase of received signal. But transmit efficient is increased in our proposed DMR system because of no using redundant data such as training sequence or CP. The proposed clock recovery algorithm is simply realized in the OFDM/QPSK-DMR system using BL-PSF. The simulation results confirm that the proposed clock recovery algorithm has the same clock phase error variance performance in a single carrier DR system under Additive White Gaussian Noise(AWGN) environment.

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.