• 제목/요약/키워드: Pulse Point

Search Result 513, Processing Time 0.024 seconds

The Study on the Contents and Satisfaction of Oriental Medicine Examination Program (한방건강검진 프로그램의 내용과 참가자들의 만족도에 관한 연구)

  • Lee Eun-Kyoung;Jahng Doo-Sub;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.51-95
    • /
    • 2002
  • 1. As a point at issue of occidental medicine examination, followings have been indicated, 1) Occidental medical examination is performed by mainly test and instrument and therefore, role of doctors could be excluded and it could be diagnosed only for target disease and 2) in Korea, it could not be conducted in public medical system and therefore improvement effect of public health promotion could not be made due to increase of total medical expenses and infirmity of post management. These points are substantial limit of paradigm resided in occidental medicine and also problem caused by unique characteristics of medical system of Korea. In Korea, result of occidental medical examination show increased health risk from aged thirties and major diagnosed diseases are circulatory disease or chronic disease such as hepatic, hyperlipemic, hypertensional disease and diabetes, etc. Accounting that those chronic disease make a role as major public health risk, it is difficult that medical examination by only occidental medicine make effect on public health promotion. 2. Characteristics of oriental medicine examination could be summarized as diagnosis (information acquisition based on the facts) and demonstration (speculation based on acquired information) and in addition, quadruple diagnosis, as a medical examination method, include test as well as basic examination. Accounting on oriental medical examination, principally it is performed by independent herbalist and therefore, herbalist could acquire systemic result during first medical examination. Based on the theory of inner-outer examination, oriental medical examination has a principle of universe theory, systemic analysis of quadruple diagnosis, demonstration & reasoning. In addition, root of oriental medical examination could be found in pre-disease theory, a principal theory of oriental medicine. Pre-disease service could prove the advantage of oriental medicine in medical examination activities and therefore, it is needed that content of oriental medical examination should be actualized in current medical system. 3. In this study, oriental medical examination program, comprised of pulse-diagnosis, contrast muscular taking and medical consultation of herbalist is progressed communally with occidental medical examination. As pre-examination, questionary was given of general characteristics, health promoting life style, physical constitution and subjective symptom of musculoskeletal system. In addition, post-examination notification was given to subjects about health promoting control, physical constitution regimen and management of musculoskeletal system. During this study program, verification was conducted for input of acquired information and difference of each information after analysis and in addition, performed was analysis of factor influencing health promoting life style and musculoskeletal subjective symptom and evaluation of relationship of physical constitution and health promoting life study. In addition, it was verified of difference between musculoskeletal subjective symptom and result of muscle contrast picture evaluation. 4. Evaluation of oriental medical examination model is divided into 2 categories of oriental medical examination-consultation and result evaluation -post management. Oriental medical examination-consultation demands establishment of examination system, standardization of examination and establishment of examination form and in addition, it should be admitted as enlarged examination assists systemic quadruple diagnosis of herbalist not a key of oriental medical examination. In addition, information acquisition for research purpose should be performed according to the systemic research plan based on the separation of questionary for examination purpose and research purpose. For evaluation of the result, it was concluded that needed are result evaluation meets oriental medical system and post-notification system, informing health management information, based on examination result. 5. Accounting on satisfaction for oriental medical examination model, affirmative reply was much higher (66%) than negative (8.64%). Satisfaction of each area was in order of consultation of herbalist, systemic muscle contrast taking, pulse examination, post-notification and questionary fill-up and dissatisfaction was in order of post-notification, questionary fill-up, consultation of herbalist, systemic muscle contrast taking and pulse measurement. Satisfaction for collaborative examination of occidental and oriental medicine was over 60% and over 75% hope oriental examination would be included in later medical examination program. Based on this result, collaborative examination including occidental and oriental medicine could increase satisfaction of subjects for medical examination program.

  • PDF

3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle (3T MR 스핀에코 T1강조영상에서 적정의 숙임각)

  • Bae, Sung-Jin;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). Materials and Method : T1-weighted images of the cerebrum of brain were obtained from 50$^\circ$ to 130$^\circ$ FA with 10$^\circ$ interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp ($\frac{-TR}{T1}$) and Ernst angle cos $\theta$ = exp ($\frac{-TR}{T1}$). Results : The SNR of WM at 130$^\circ$ FA is approximately 1.6 times higher than the SNR of WM at 50$^\circ$. The SNR of GM at 130$^\circ$ FA is approximately 1.9 times higher than the SNR of GM at 50$^\circ$. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120$^\circ$ FA, the SNR of GM started decreasing at less than 110$^\circ$. The highest SNRs of WM and GM were obtained at 130$^\circ$ FA. The highest CNRs, however, were obtained at 80$^\circ$ FA. Conclusion : Although SNR increased with the change of FA values from 50$^\circ$ to 130$^\circ$ at 3T SE T1WI, CNR was higher at 80$^\circ$ FA than at the usually used 90$^\circ$ FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  • PDF

Effect of Sa-am Acupuncture Method for Chronic Tension-type Headache;A Randomized Controlled Trial (만성 긴장성 두통 환자에 대한 사암침 치료효과의 Pilot 임상연구)

  • Hong, Kwon-Eui;Park, Yang-Chun;Jo, Jeong-Hyo;Jo, Hyun-Gyeong;Jeong, In-Cheol;Kang, Wee-Chang;Lee, Sang-Bong;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.24 no.1
    • /
    • pp.13-28
    • /
    • 2007
  • Objectives : Clinical character of chronic tension-type headache is bilateral, moderate intensity, persistent and chronic, repeating disease and CTTH is a common prevalent disease, but pathophysiology and likely mechanism remain unclear. It impedes subjective quality of life. The purpose of this research is to examine the effect of sa-am acupuncture method for chronic tension-type headache. Methods : In this randomized, single blind, placebo-controlled study, we compared active acupuncture with sham acupuncture for the treatment of chronic tension-type headache. Volunteers who satisfied the requirements were enrolled in study. Evaluation of chronic tension-type headache was measured by VAS and Headache Disability Inventory(HDI), Six point Linkert Scale before and after treatments. Results : 26 subjects finished study. There were not difference between two groups on age, sex, weight, height, blood pressure, pulse, respiratory rate, Byeonjeung, sunrise of treatment. In change of VAS, there were not difference between two groups on before treatment. Before treatment per visit, VAS of 6th and 7th visit were significantly decreased in active acupuncture(each p=0.039, p=0.008) and were not decreased in sham acupuncture. In change of VAS on a withdrawing needling after treatment, VAS of 1st, 2nd, 6th and 7th visit were significantly decreased in active acupuncture (each p=0.001, 0.038, 0.035, 0.008) and VAS of 2nd, 4th and 5th, 6th visit were significantly decreased in sham acupuncture(each p=0.033, 0.032, 0.035, 0.031). In change of VAS on 2hrs after treatment, VAS of 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.014, 0.023, 0.027) and 5th visit were significantly decreased in sham acupuncture(each p=0.004, 0.009). In change of VAS on 4hrs after treatment, VAS of 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.018, 0.011, 0.015) and 5th, 6th visit were significantly decreased in sham acupuncture(each p=0.020, 0.015). In change of VAS on the next day after treatment, VAS of 3th and 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.032, 0.011, 0.005, 0.012) and 4th, 5th visit were significantly decreased in sham acupuncture(each p=0.001, 0.012). In change of VAS according to a current time(before treatment, after a withdrawing needling, 2hrs, 4hrs, the next day), total score of VAS was decreased more active acupuncture group than sham acupuncture group, but there were no statistical significance compared with sham acupuncture group. In change of HDI score, after treatment was decreased than before treatment in two group, but there were no statistical significance compared with two group. In change of Six point Linkert scale score, after treatment was decreased than before treatment in two group on 6th, 7th visit(active acupuncture 6th 7th each p=0.002, 0.003, sham acupuncture 6th 7th each 0.003, 0.009), but there were no statistical significance compared with tow group. Conclusion : Sa-am acupuncture treatment is effective to improve the symptoms and quality of life in patients with chronic tension-type headache.

  • PDF

The Continuous Monitoring of Oxygen Saturation During Fiberoptic Bronchoscopy (기관지내시경 검사시 지속적인 동맥혈 산소포화도 감시의 필요성)

  • Kang, Hyun Jae;Kim, Yeon Jae;Chyun, Jae Hyun;Do, Yun Kyung;Lee, Byung Ki;Kim, Won Ho;Park, Jae Yong;Jung, Tae Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.385-394
    • /
    • 2002
  • Background : Flexible fiberoptic bronchoscopy(FFB) has become a widely performed technique for diagnosing and managing pulmonary disease because of its low complication and mortality rate. Since the use of FFB can in patients with severely depressed cardiorespiratory function is increasing and hypoxemia during the FFB can induce significant cardiac arrhythmias, the early detection and adequate management of hypoxemia during FFB is clinically important. Method : To evaluate the necessity of the continuous monitoring of the oxygen saturation($SaO_2$) during the FFB, the $SaO_2$ was continuously monitored from the finger tip using pulse oximetry before, during and after the FFB in 379 patient. The patients were then divided into two groups, those with and without hypoxemia($SaO_2$<90%). The baseline pulmonary function data and the clinical characteristics of the two groups were compared. Results : The mean baseline $SaO_2$ was $96.9{\pm}2.85%$. An $SaO_2$ <90% was recorded at some point in 62(16.4%) out of 379 patients, with 12 out of 62 experiencing this prior to the FFB, in 37 out of 62 during the FFB, and in 13 out of 62 after the FFB. No differences were observed in the smoking and sex distribution between those with and without hypoxemia. The mean age was older in those with hypoxemia than in those without. Significant differences were observed in the mean baseline $SaO_2$ and the mean time for the procedure between the two groups. The $FEV_1$ was significantly lower in those with hypoxemia, and both the FVC and $FEV_1/FVC$ also tended to decrease in this group. Managing hypoxemia included deep breathing in 20 patients, a supplemental oxygen supply in 39 patients, and the abortion of the procedure in 3 patients. Conclusion : These results suggest that the continuous monitoring of the oxygen saturation is necessary during fiberoptic bronchoscopy, and it should be performed in patients with a depressed pulmonay function in order for the early detection and adequate management of hypoxemia.

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF

Fabrication and Evaluation of a VHF Focusing Ultrasonic Transducer Made of PVDF Piezoelectric Film (PVDF 압전막을 이용한 초고주파 집속 초음파 트랜스듀서의 제작 및 특성 평가)

  • Yoon, Ju-Ho;Oh, Jung-Hwan;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.215-222
    • /
    • 2011
  • In order to obtain high resolution images, a focusing ultrasonic transducer operated in very high frequency (VHF) range was fabricated and its characteristics were evaluated. A 9-${\mu}m$ thick PVDF film with only one metalized surface for electric ground was adhered to a CCP (Copper-clad polyimide) film by using epoxy. It was pressed by a metal ball to form a concave surface and its rear side was filled with the epoxy. The radius of curvature and the f-number of the fabricated transducer are 7.5 mm and 1.7, respectively. The pulse-echo measurement results from a target located at the focal point showed that the frequency bandwidth was 35.0 MHz and the insertion loss near the peak frequency of approximately 40 MHz was about 60 dB. Those values agreed well with the simulation results by the KLM equivalent circuit analysis including the effect of the epoxy bonding layer. When the image of thin copper lines by the 35 MHz transducer of the UBM (Ultrasonic Backscattering Microscope) system was compared with the image by the transducer fabricated in this study, the fabricated transducer was observed that the axial resolution was improved although the lateral resolution was degraded.

High-intensity focused ultrasound beam path visualization using ultrasound imaging (초음파 영상을 이용한 고강도 집중 초음파 빔 시각화)

  • Song, Jae Hee;Chang, Jin Ho;Yoo, Yang Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-23
    • /
    • 2020
  • In High-Intensity Focused Ultrasound (HIFU) treatment, effective localization of HIFU focus is important for developing a safe treatment plan. While Magnetic Resonance Imaging guided HIFU (MRIgHIFU) can visualize the ultrasound path during the treatment for localizing HIFU focus, it is challenging in ultrasound imaging guided HIFU (USIgHIFU). In the present study, a real-time ultrasound beam visualization technique capable of localizing HIFU focus is presented for USIgHIFU. In the proposed method, a short pulse, with the same center frequency of an imaging ultrasound transducer below the regulated acoustic intensity (i.e., Ispta < 720 mW/㎠), was transmitted through a HIFU transducer whereupon backscattered signals were received by the imaging transducer. To visualize the HIFU beam path, the backscattered signals underwent dynamic receive focusing and subsequent echo processing. From in vitro experiments with bovine serum albumin gel phantoms, the HIFU beam path was clearly depicted with low acoustic intensity (i.e., Ispta of 94.8 mW/㎠) and the HIFU focus was successfully localized before any damages were produced. This result indicates that the proposed ultrasound beam path visualization method can be used for localizing the HIFU focus in real time while minimizing unwanted tissue damage in USIgHIFU treatment.

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

Level of Obstructive Sleep Apnea of Patients with Ischemic Cardio-cerebrovascular Disease and Affecting Factors (허혈성 심뇌혈관질환자에서 폐쇄성 수면무호흡증 정도 및 영향요인)

  • Kim, Sun Hwa;Hwang, Seon Young
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.114-127
    • /
    • 2018
  • This study aimed to investigate the levels of Obstructive Sleep Apnea (OSA), health behavior and sleep quality and to examine the predictors of OSA in patients with ischemic cardio-cerebrovascular disease. 141 patients who were admitted to the vascular unit were recruited and surveyed using structured questionnaires. Saturation of Peripheral Oxygen (SpO2) was measured at three time points using a pulse oximeter. Data were analyzed using SPSS/WIN 20.0. The mean age of the subjects was $64.4{\pm}11.1$ years and 61% was men. The 21.3%(n=30) of the subjects were classified as high-risk for OSA by the cut point and 71.6%(n=101) had low sleep quality. OSA high-risk group showed significant difference in SpO2 in the middle of sleep (p=.006) and at the end of sleep (p=.004) compared to the low-risk group. Multiple logistic regression analysis showed that perceived frequent snoring, smoking, obesity, lack of exercise among health behavior were found as predicting factors on OSA. OSA or persistent snoring should be recognized as a cardiovascular risk factor in the cardiovascular nursing practice. In addition to early treatment of OSA, education and counseling should be provided to patients and their family for prevention of secondary recurrence.

The Effect of Electric Acupuncture Therapy on Myofascial Pain Syndrome (근근막 동통증후군과 전침(Electric Acupuncture)치료의 유효성에 관한 연구)

  • Jung, Mun-Boung;Lee, Sang-Han;Min, Boung-Ki;Yoon, Mi-Yean
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.1
    • /
    • pp.897-903
    • /
    • 1999
  • Many out patients of the rehabilitation center complaint a pain caused by suffering of MPS, and it brings many different kind of social and ecinomical problems such as medical expenses and the reduction in work efficiency. Therefore, we conducted a research to present a fast and effective treatment to the MPS patients. this research was conducted from November, 1996 to January 1998 with eighteen outpatients who agreed to be the subjects to our reserach. We applied the electric acupuncture on 28 different trigger point on the patients with mostly muscular-skeletal pain and some tender and radiating pain. After the treatment, VRS, VAS, PRI were used to measure the degree of the pain on the patients third and seventh visits, and following results were found. 1. To apply EAP treatment, we acupunctured 6em-Iong needles on Tps region, then the electrodes of pulse generater pg-306 E.S.T were connected on the top of the needles. the electric acupuncture therapy was conducted for 20 minutes with the intensity of 4hz - 60hz(auto wave). The treated electric intensity was the level at which the patients did not feel discomfort. 2. Thirteen out of the 18 participated patients were in their 30s and 40s(72.2%), showing highest frequency. There were more female than male with the ratio of 1 to 1:2. 3. six out of the participated patients (33.3%) had the pain for less then a week, and the average duration of the pain of the participated patients wear 0.8 years. 4. The pain occured mostly in the upper trapezius by 6 part (21.4%), then in the gluteus medius region by 4 part (14.3%). Many of the patients with the pain in the upper back area accompanied varios kind of the referred pains such as radiculopathy, HIVD and Frozen shoulder. 5. MPS occured more frequently on the right side than left side then left side and it seemed to be due to the frequent use of the right hand. 6. There was almost no difference in the measurement of the intensity of the pain right before and after the EAP treatment. Howerver, there was significant decrease in the numerical values of the VAS, and a little bit of decrease in the numerical values of the PRI after the EAP treatment. 7. Based on the results of this present research, it can be concluded that EAP can be used for the treating the myofascial pain syndrome with promptness and safety in most cases.

  • PDF