• Title/Summary/Keyword: Pulse Point

Search Result 514, Processing Time 0.028 seconds

A Study on the Electrical Characteristics of Ge2Sb2Te5/Ti/W-Ge8Sb2Te11 Structure for Multi-Level Phase Change Memory (다중준위 상변환 메모리를 위한 Ge2Sb2Te5/Ti/W-Ge8Sb2Te11 구조의 전기적 특성 연구)

  • Oh, Woo-Young;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.1
    • /
    • pp.44-49
    • /
    • 2022
  • In this paper, we investigated current (I)- and voltage (V)-sweeping properties in a double-stack structure, Ge2Sb2Te5/Ti/W-doped Ge8Sb2Te11, a candidate medium for applications to multilevel phase-change memory. 200-nm-thick and W-doped Ge2Sb2Te5 and W-doped Ge8Sb2Te11 films were deposited on p-type Si(100) substrate using magnetron sputtering system, and the sheet resistance was measured using 4 point-probe method. The sheet resistance of amorphous-phase W-doped Ge8Sb2Te11 film was about 1 order larger than that of Ge2Sb2Te5 film. The I- and V-sweeping properties were measured using sourcemeter, pulse generator, and digital multimeter. The speed of amorphous-to-multilevel crystallization was evaluated from a graph of resistance vs. pulse duration (t) at a fixed applied voltage (12 V). All the double-stack cells exhibited a two-step phase change process with the multilevel memory states of high-middle-low resistance (HR-MR-LR). In particular, the stable MR state is required to guarantee the reliability of the multilevel phase-change memory. For the Ge2Sb2Te5 (150 nm)/Ti (20 nm)/W-Ge8Sb2Te11 (50 nm), the phase transformations of HR→MR and MR→LR were observed at t<30ns and t<65ns, respectively. We believe that a high speed and stable multilevel phase-change memory can be optimized by the double-stack structure of proper Ge-Sb-Te films separated by a barrier metal (Ti).

The Effect of S130A Mutant of pharaonis Halorhodopsin on Ability of Chloride Binding and Photocycle

  • Sato, Maki;Kikukawa, Takashi;Araiso, Tsunehisa;Okita, Hirotaka;Shimono, Kazumi;Kamo, Naoki;Demura, Makoto;Nitta, Katsutoshi
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.308-310
    • /
    • 2002
  • Bacteriorhodopsin (bR) and halorhodopsin (hR), which exist in the membrane of Halobacterium salinarum, are light-driven ion pumps. In spite of high similarity of primary and tertiary structures between bR and hR, these membrane proteins transport different ions, proton and chloride, in the opposite direction. From alignment of the amino acid sequences, Thr-89 of bR is homologous to Ser-l15 of hR from Halobacterium salinarum (shR). X-ray structure of shR has revealed that OH group of this residue directly interacts with CI$\^$-/ Thus, Ser-lI5 of shR is expected to play an important role in CI$\^$-/ binding and transport. In this study, we expressed wild type hR from Natronobacterium pharaonis (PhR) and Sl30A, which corresponds to Ser-l15 of shR, in E. coli in order to clarify binding affinity of chloride ion and photocycle reactions. From the titration with CI$\^$-/, affinity of Sl30A became quite lower than that of WT (WT 6 mM, Sl30A 89 mM). Furthermore, from the flash photolysis with pulse laser of λ$\_$max/ at 532 nm, the reaction rate of SI30A from 0 intermediate to hR ground state was found to become apparently slower than that of WT. The singular value decomposition (SVD) and global fitting analyses of the photocycles were performed to identify all photointermediates and determine the reaction rates.

  • PDF

[ $T_2$ ]-relaxation Time Measurement of ex vivo $^1H$ MR Metabolite Peaks for Evaluation of Human Stomach Cancer

  • Mun Chi-Woong;Choi Ki-Sueng;Shin Oon-Jae;Yang Young-Ill;Chang Hee-Kyung;Hu Xiaoping;Eun Chung-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.53-58
    • /
    • 2006
  • In this study, transverse relaxation time (T2) measurement and the evaluation of the characteristics of the spectral peak related to stomach tissue metabolites were performed using ex vivo proton magnetic resonance spectroscopic imaging (MRSI) at 1.5-T MRI/S instruments. Thirty-two gastric tissues resected from 12 patients during gastric cancer surgery, of which 19 were normal tissue and 13 were cancerous tissue, were used to measure the $T_2$ of the magnetic resonance spectroscopy (MRS) peaks. The volume of interest data results from the MRSI measurements were extracted from the proper muscle (MUS) layer and the composite mucosa/submucosa (MC/SMC) layer and were statistically analyzed. MR spectra were acquired using the chemical shift imaging (CSI) point resolved spectroscopy (CSI-PRESS) technique with the parameters of pulse repetition time (TR) and echo times (TE) TR/(TE1,TE2)=1500 msec/(35 msec, 144 msec), matrix $size=24{\times}24$, NA=1, and voxel $size=2.2{\times}2.2{\times}4mm^3$. In conclusion, the measured $T_2$ of the metabolite peaks, such as choline (3.21ppm) and lipid (1.33ppm), were significantly decreased (p<0.01 and p<0.05, respectively) in the cancerous stomach tissue.

Dynamic Respiratory Measurements of Corynebacterium glutamicum using Membrane Mass Spectormetry

  • Wittmann.Christoph;Yang, Tae-Hoon;Irene Kochems;Elmar Heinzle
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.1
    • /
    • pp.40-49
    • /
    • 2001
  • The present work presents a novel approach for the dynamic quantification of respiration rates on a small scale by using lysine-producing Corynebacterium glutamicum ATCC 21253. Cells sampeld from batch cultures at different times were incubated ina 12-ml scale bioreactor equipped with a membrane mass spectrometer. Under dynamic conditions, gas exchange across the gas-liquid phase, specific respiration rates, and RQ values were precisely measured. For this purpose, suitable mass balances were formulated. The transport coefficients for $O_2$ and $CO_2$, crucial for calculating the respiration activity, were determined as $k_La_{O2}=9.18h^{-1}$ and $k_La_{CO2}=5.10h^{-1}$ at 400 rpm. The application of the proposed method to batch cultures of C. glutamicum ATCC 21253 revealed the maximum specific respiration rates of $q_{O2}=8.4\;mmol\;g^{-1}h^{-1}\;and\;q_{CO2}=8.7\;mmol\;g^{-1}h^{-1}$ in the middle of the exponential growth phase after 5 h of cultivation. When the cells changed from growth to lysine production due to the depletion of the essential amino acids theonine, methionine, and leucine, $q_{O2}\;and\;q_{CO2}$ decreased significantly and RQ increased. The respiration data exhibited an excellent agreement with previous cultivations of the strain [13]. This confirms the potential of the developed approach to realistically reflect the metabolic activities of cells at their point of sampling. The short-term influence of added threonine, methionine, and leucine was highest during the shift from growth to lysine production, where $q_{O2}\;and\;q_{CO2}$ increased 50% within one minute after the pulse addition of these compounds. Non-growing, yet lysine-producing cells taken from the end of the batch cultivation revealed no metabolic stimulation with the addition of threonine, methionine, and leucine.

  • PDF

Spectral Analysis of Transient Elastic Waves Generated by Point Source in Glass and Unidirectional CFRP Plates (유리판과 단일방향 탄소섬유강화 플라스틱판에서 점원에 의해 발생된 과도적 탄성파의 주파수 해석)

  • Lee, Jeong-Ki;Kim, Ho-Chul;Choi, Myoung-Seon;Kim, Young-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.50-59
    • /
    • 1994
  • Spectral analysis of transient elastic waves were carried out in order to identify the propagation modes in glass and unidirectional carbon fibre reinforced plastic (CFRP) plates. Pencil leads were broken on the surface of plates to generate elastic waves, and two broad band transducers of 6.35 mm in diameter and 10 MHz center frequency were placed at the linear location from the source. The frequency spectra of detected signals showed that the wave propagation in the plates obeyed the Lamb wave dispersion relation. The transient signals were the fast propagating modes around maximum group velocity of the lowest and first order symmetric $modes(S_{0} and S_{1}),$ and first order antisymmetric $mode(A_{1})$. The transient signals were not severely distorted due to relatively small dispersion of those modes around the maximum group velocity. The fastest propagating mode in the plates was shown to be $S_{0}$ mode less the than cut-off frequency of $A_{1}$ mode.

  • PDF

Properties of $CaO-P_2O_5-SiO_2$ Glasses ($CaO-P_2O_5-SiO_2$계 유리의 물성)

  • 조정식;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.4
    • /
    • pp.289-298
    • /
    • 1993
  • Properties in terms of the variation of the glass compositions, which were density (p), molar volume(Vm), atom/ion packing density (Dp), refractive index (nD), transformation temperature (Tg), dilatometric softening point (Td), thermal expansion coefficient (α), Young's modulus (E), and knoop hardness (KHN) were investigated in CaO-SiO2 glasses and CaO-P2O5-SiO2 glasses containing less than 10mole% of P2O5. Those properties were measured by density measurement kit, Abbe refractometer, dilatometer, ultrasonic pulse echo equipment, and micro hardness tester. When CaO content was increased in CaO-SiO2 glasses, p, Dp, nD, Tg, Td, α, E and KHN were increased, while Vm was decreased. When P2O5 was added to the CaO-SiO2 glasses with constant CaO/SiO2 ratio as 1.07, p, Dp, nD, Tg, Td, α, E and KHN were decreased, while Vm was increased. When the amount of P2O5 in glasses was kept constant, the changes of the properties with variation of CaO content in the CaO-P2O5-SiO2 glasses were very similar to those of CaO-SiO2 glasses. These phenomena could be explained by the structural role of P2O5 in the CaO-P2O5-SiO2 glasses, which was polymerization of siicate structures and resulted in [PO4] monomer structure in glasses. Due to this structural characteristics, the bond strength and packing density were changed with compositions. Proportional relationships between 1) np and Dp, 2) Tg, Td, α and CaO content, 3) E and Vm-1, and 4) KHN and P2O5 content were evaluated in this investigation.

  • PDF

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Optical Characteristics and Measurement System of Charged Particle Type Display (대전입자형 디스플레이 소자의 측정시스템 및 광학특성)

  • Kim, Baek-Hyun;Kim, Soung-Woon;Lee, Sang-Kug;Kim, Young-Cho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • We fabricated the 4 channel wave function generator with variable frequency, pulse width, amplitude and rising/falling slope to develop driving method of charged particle type display. The selective sell driving is ascertained by fabricated panel with black and yellow particles. To measure CIE point, reflectivity, contrast ratio and viewing angle, experimental apparatus is integrated with optical circular$(1^{\circ})$ moving emitting/receiving part and spectrometer connected to emitting part. The yellow particles in glass have reflectivity of $35{\sim}40%$ and wavelength of 571.2nm and black one has reflectivity of $15{\sim}20%$ in case of only 1 layer of particle, and the case of 3 layer the optical property is promoted.

Sensorless Detection of Position and Speed in Brushless DC Motors using the Derivative of Terminal Phase Voltages Technique with a Simple and Versatile Motor Driver Implementation

  • Carlos Gamazo Real, Jose;Jaime Gomez, Gil
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1540-1551
    • /
    • 2015
  • The detection of position and speed in BLDC motors without using position sensors has meant many efforts for the last decades. The aim of this paper is to develop a sensorless technique for detecting the position and speed of BLDC motors, and to overcome the drawbacks of position sensor-based methods by improving the performance of traditional approaches oriented to motor phase voltage sensing. The position and speed information is obtained by computing the derivative of the terminal phase voltages regarding to a virtual neutral point. For starting-up the motor and implementing the algorithms of the detection technique, a FPGA board with a real-time processor is used. Also, a versatile hardware has been developed for driving BLDC motors through pulse width modulation (PWM) signals. Delta and wye winding motors have been considered for evaluating the performance of the designed hardware and software, and tests with and without load are performed. Experimental results for validating the detection technique were attained in the range 5-1500 rpm and 5-150 rpm under no-load and full-load conditions, respectively. Specifically, speed and position square errors lower than 3 rpm and between 10º-30º were obtained without load. In addition, the speed and position errors after full-load tests were around 1 rpm and between 10º-15º, respectively. These results provide the evidence that the developed technique allows to detect the position and speed of BLDC motors with low accuracy errors at starting-up and over a wide speed range, and reduce the influence of noise in position sensing, which suggest that it can be satisfactorily used as a reliable alternative to position sensors in precision applications.

A Study on Digital Control Method of LED Luminance (LED 휘도의 디지털 제어 방식에 관한 연구)

  • Kang, Shin-Ho;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • The pulse width modulation(PWM) method has been generally used as conventional method controlling luminance of LED(light emitting diode). PWM method as analog method with a relation that duty ratio of LED be proportional to luminance has weak point that it is not compatible with digital method of communication etc. In this paper, a experiment is conducted which the luminance of RGB LED be controlled by digital method. For this, the LED digital control system is developed which consist of LED driving circuits and digital logic circuits. By controlling the number of pluses on RGB LED versus digital input, various lighting colors is implemented and digital codes are optimized in order that measured x, y chromaticity coordinates of lighting colors are comprised in the CIE chromaticity coordinates area of targeted lighting colors. The result of this study can be utilized usefully in research on implementing full color by using remote control of LED lamp with digital communication.