• Title/Summary/Keyword: Pulse Mode

Search Result 756, Processing Time 0.028 seconds

Simple Q-switched Waveguide $CO_2$ Laser Using Polygon Mirror (회전 다면셩을 이용한 도파관 $CO_2$ 레이저의 Q-스위칭)

  • 최종운;김용평;강응철;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.21-25
    • /
    • 1995
  • Q-switched Waveguide $CO_{2}$ laser using polygon mirror were constructed and their output characteristics were measured. Waveguide was made of the beryllium oxide tube of inner diameter of 2 mm, outer diameter of 20 mm, and length of 200 mm. A flat ZnSe output coupler of 80% reflectivity was placed on the 9 mm distance from the end of the waveguide. Convex lens was used to reduce the coupling loss between the polygon mirror and the waveguide. The polygon mirror was located behind of convex lens. With this condition, continuous output of the laser were measured as 1.2 W. In the Q-switched mode. pulse width 120 ns were measured with rotational speed 7,559 RPM. and peak power of up to 250 W. 250 W.

  • PDF

Behavior of Natural Organic Matter(NOM), Chlorine Residual, and Disinfection By-Products(DBPs) Formation in Pulsed UV Treated Water (Pulsed UV 처리수에서의 자연유기물질, 잔류염소 및 소독부산물 생성 거동)

  • Sohn, Jinsik;Han, Jihee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.685-692
    • /
    • 2012
  • UV technology is widely used in water and wastewater treatment. Many researches have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on NOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics such as NOM. Pulsed UV treatment using UV flash lamp can be operated in the pulsed mode with much greater peak intensity. The pulse duration is typically in microseconds, whereas the interval between pulses is in the order of milliseconds. The high intensity of pulsed UV would mineralize NOM itself as well as change the characteristics of NOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of NOM. The objective of this study is to investigate the effect on NOM, chlorine residual, and chlorinated DBPs formation with pulsed UV treatment.

A Study of Lighting Flxtures Power Supply That Use Current Control (전류제어를 이용한 등기구 전원장치에 관한 연구)

  • Lee, Byung-Sun;Kim, Young Sun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.199-204
    • /
    • 2012
  • The study for developments and economics about the energies from the global warming is very active. For the effective saving and the spanning of the life extension about the 19% rates for the illumination system spending power about the whole electric energies, we proposed the new type of the current control method using a mixing system of the frequency modulation together with the pulse width modulation for the half-bridge power instrument. And we proved the excellence and the stability for our suggested system and analyzed the characteristics.

Development of Uninterruptible Power Supply with Voltage Sag Restorer Function (순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

Novel Scanning Tunneling Spectroscopy for Volatile Adborbates

  • Choi, Eun-Yeoung;Lee, Youn-Joo;Lyo, In-Whan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.58-58
    • /
    • 2010
  • Reactive or unstable adsorbates are often difficult to study spectroscopically. They may have, for instance, resonance states lying close to the Fermi level, inducing them to desorb or decompose by the probe itself, low-energy tunneling electrons. In order to overcome this limitation, we developed a novel method, which we call x-ramp scan. The method sweeps the bias voltage, with the simutaneous scan along the imaging direction, in a constant current mode. This mapping yields the tip-height variation as a function of bias, or Z(V), at nominally always fresh surface. We applied this method to the investigation of methanol-induced molecular features, attributed to methoxy, found on NiAl(110) surface. These were produced by methanol molecules deposited by a pulse injection method onto the metallic surface. Our study shows adsorbed methoxy are very reactive to the bias voltage, rendering the standard spectroscopy useless. Our new x-ramp scan shows that the decomposition of adsorbates occurs at the sample bias of 3.63 V, and proceeds with the lifetime of a few milliseconds. The details of the method will be provided at the discussion.

  • PDF

Single stage Boost Input Type Resonant AC/DC Converter (단일단 부스트 입력방식의 공진형 AC/DC 컨버터)

  • 연재을;정진범;김희준
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.65-72
    • /
    • 2004
  • This paper proposes the novel boost input type resonant AC/DC converter. Since the proposed converter is single stage topology, it controls both of the input power factor and the output voltage at the same time, and resultingly obtains the high power factor of 99% with average current mode pulse width modulation. Especially, to accomplish the zero voltage switching, the resonance between the leakage inductance and external capacitor is used. For the theoretical consideration of the proposed converter, the six operation modes divided by means of current path are discussed, and the resonance characteristics in steady state are analyzed. To verify the validity of the proposed converter, a 200[W]($120[V_AC],\; 출력\; 48[V_DC],\; 4[A]$prototype converter was built and its experimental results were presented in this paper.

An Improved Central 60° Synchronous Modulation for High Transient Performance with PMSM Stator Flux Control Used in Urban Rail Transit Systems

  • Fang, Xiaochun;Lin, Fei;Yang, Zhongping
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.542-552
    • /
    • 2016
  • Central 60° synchronous modulation is an easy pulse-width modulation (PWM) method to implement for the traction inverters of urban rail trains at a very low switching frequency. Unfortunately, its switching patterns are determined by a Fourier analysis of assumed steady-state voltages. As a result, its transient responses are not very good with over-currents and high instantaneous torque pulses. In the proposed solution, the switching patterns of the conventional central 60° modulation are modified according to the dynamic error between the target and actual stator flux. Then, the specific trajectory of the stator flux and current vector can be guaranteed, which leads to better system transients. In addition, stator flux control is introduced to get smooth mode switching between the central 60° modulation and the other PWMs in this paper. A detailed flow chart of the control signal transmission is given. The target flux is obtained by an integral of the target voltage. The actual PMSM flux is estimated by a minimum order flux state observer based on the extended flux model. Based on a two-level inverter model, improved rules in the α-β stationary coordinate system and equations of the switching patterns amendment are proposed. The proposed method is verified by simulation and experimental results.

A Study on Isolated DC-DC Converter of DCM (절연형 DCM DC-DC 컨버터에 관한 연구)

  • Kwak, D.K.;Lee, B.S.;Kim, C.S.;Shim, J.S.;Yu, J.H.;Son, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.15-16
    • /
    • 2010
  • This paper is study on a high efficiency DC-DC converter of discontinuous conduction mode (DCM) added electric isolation. The converters of high efficiency are generally made that the power losses of the used semiconductor switching devices is minimized. To achieve high efficiency system, the proposed converter is constructed by using a quasi resonant circuit. The control switches using in the converter are operated with soft switching by quasi resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of the system is high. The proposed converter is also added electric isolation which is used a pulse transformer. When the power conversion system is required electric isolation, the proposed converter is adopted with the converter system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter are verified by digital simulation and experimental results.

  • PDF

Implementation of an Interleaved AC/DC Converter with a High Power Factor

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.377-386
    • /
    • 2012
  • An interleaved bridgeless buck-boost AC/DC converter is presented in this paper to achieve the characteristics of low conduction loss, a high power factor and low harmonic and ripple currents. There are only two power semiconductors in the line current path instead of the three power semiconductors in a conventional boost AC/DC converter. A buck-boost converter operated in the boundary conduction mode (BCM) is adopted to control the active switches to achieve the following characteristics: no diode reverse recovery problem, zero current switching (ZCS) turn-off of the rectifier diodes, ZCS turn-on of the power switches, and a low DC bus voltage to reduce the voltage stress of the MOSFETs in the second DC/DC converter. Interleaved pulse-width modulation (PWM) is used to control the switches such that the input and output ripple currents are reduced such that the output capacitance can be reduced. The voltage doubler topology is adopted to double the output voltage in order to extend the useable energy of the capacitor when the line voltage is off. The circuit configuration, principle operation, system analysis, and a design example are discussed and presented in detail. Finally, experiments on a 500W prototype are provided to demonstrate the performance of the proposed converter.

Effect of Delay Time Control on the Spatter Generation in $CO_2$ Welding ($CO_2$ 용접에서 스패터 발생에 미치는 지연시간 제어의 영향)

  • 이창한;김희진;강봉용
    • Journal of Welding and Joining
    • /
    • v.17 no.5
    • /
    • pp.61-68
    • /
    • 1999
  • For the last two decades, waveform control techniques have been successively developed and applied for the inverter welding machines resulting in the substantial reduction of spatter generated in CO₂ welding. One of the constituents commonly involved in those techniques is to delay the instant of current increase to some extent after the initiation of short-circuiting. Although this technique has been known to be quite effective in reducing the spatter generation through the suppression of is instantaneous short circuiting, the delay time necessary for minimum spatter has not been clearly understood. In this study, the control system for varying the delay time was constructed so that the spatter generation rates could be measured over a wide range of delay time, 0.29-2.0 msec. As a result of this study, it was demonstrated that spatter generation rate(SGR) sharply decreased at delay time of 0.6 msec and longer accompanied with the change in characteristics of short circuit mode from the instantaneous short-circuiting(ISC) dominant to normal short-circuiting(NSC) dominant. Another feature that have been found in current waveform of over 0.6msec was the creation of current pulse right after the arc reignition stage. Because of this current pulses weld pool oscillated in wave-like fashion and it looks like to play an important role in developing short circuiting between electrode and weld pool.

  • PDF