• 제목/요약/키워드: Pulse Measurement

검색결과 949건 처리시간 0.029초

난임 여성의 체질량지수(BMI), 불임기간에 따른 맥파 연구 (A study on the pulse wave factor according to BMI and period of sterility on female)

  • 김경철;김이순
    • 한국한의학연구원논문집
    • /
    • 제18권2호
    • /
    • pp.139-149
    • /
    • 2012
  • Objectives : This is the study to understand of the pulse wave factor according to BMI and period of sterility on female, and to confirm the relationship of pulse wave factor among left and right inch, bar and cubit. Methods : The Questions and measurement of the pulse wave were operated with subjects(76 sterile females using on public health center). The measurement of the pulse wave was operated in 6 part of left and right inch, bar and cubit. The pulse wave was prior measured in part of left bar (i.e. interior pulsation part of radial process styloides in left hand), and next was measured in part of left inch and bar. And the pulse wave was operated samely in part of right inch, bar and cubit. Results : The results were as follows. The pulse energy of 6 part of left and right inch, bar and cubit was showed statistical significance and decreased in order of left inch, right inch, left cubit, right cubit, left inch, right bar. The left and right inch and cubit were showed numerical value of normal range, but left and right bar were showed lower pulse eneregy than normal range. Also left and right cubit were showed lower than left and right inch, and higher than left and right bar. In BMI, The pulse energy of left and right inch, cubit and the average of right hand was not showed statistical significance in the range of low-weight, normal, over-weight and obesity. But in the left and right bar and the average of left hand, the pulse energy of over-weight and obesity group were showed significantly higher than low-weight group. And the pulse wave factor was divided the pattern of h1 showing high numerical value in inch (Ap, As, Aw) and the pattern of Wm showing high numerical value in bar and cubit (RAI, Ad) Conclusions : The low pulse energy of bar was significant observation on the setting of oriental medical diagnostic index on sterilitas. Also, in the numerical value pattern of diverse pulse wave factor, it was divided the pattern of high numerical value in inch and the pattern of high numerical value in bar and cubit. On this, we think that the studies need in the future.

실시간 공정신호를 통한 용접공정 알고리즘에 관한 연구 (A Study on Welding Process Algorithm through Real-time Current Waveform Analysis)

  • 윤진영;이영민;신순철;최해운
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.24-29
    • /
    • 2015
  • The current waveform was analysed to monitor the weld quality in real time process. The acquired current waveform was discretely analysed for the top and bottom limits of peaks as well as the pulse frequency measurement. Fast Fourier Transform was implemented in the program to monitor the pulse frequency in real time. The developed algorithm or program was tested for the validation purpose. The cross-section of weld profile was compared to the current waveform profile to correlate the monitored signal and the actual parts. Pulse frequency was also used as auxiliary tool for the quality monitoring. Based on the results, it was possible to evaluate the quality of welding by measure the current waveform profile and frequency measurement.

Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I) (A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l))

  • 강동식;이우영;박정후;곽영순;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

Measurement and Prediction of Damage Threshold of Gold Films During Femtosecond Laser Ablation

  • Balasubramani, T.;Kim, S.H.;Jeong, S.H.
    • 한국레이저가공학회지
    • /
    • 제11권4호
    • /
    • pp.13-20
    • /
    • 2008
  • The damage threshold measurement of gold films is carried out with ultrashort-pulse laser. An enhanced two temperature model is developed to encounter the limitation of linear modeling during ultrashort pulse laser ablation. In which the electron heat capacity is calculated using a quantum mechanical approach based on a Fermi-Dirac distribution, temperature-dependent electron thermal conductivity valid beyond the Fermi temperature is adopted, and reflectivity and absorption coefficient are estimated by applying a temperature-dependent electron relaxation time. The predicted damage threshold using the proposed enhanced modelclosely agreed with experimental results, demonstrating the importance of considering transient thermal and optical properties in the modeling of ultrashort pulse laser ablation.

  • PDF

지그비 기반의 심전도 센서노드를 사용한 적응형 심박탐지 모델 (An adaptive pulse measurement mechanism using ECG sensor node based on Zigbee)

  • 이병문;박연희;이영호
    • 인터넷정보학회논문지
    • /
    • 제10권3호
    • /
    • pp.27-33
    • /
    • 2009
  • u-헬스케어 시대가 도래 하면서, 심장질환자의 생체신호 모니터링 형태가 바뀌고 있다. 현재의 심장 질환자의 생체신호 모니터링은 각종 심전도 측정기기에 달린 케이블 때문에 상당한 불편을 감수해야 했다. 그러나 최근 들어 무선 센서 네트워크를 이용하면 케이블로 인한 불편이 감소되고 이동이 자유로울 수 있기 때문에 심전도 데이터를 무선으로 전송하는 기술이 활발히 연구되고 있다. 물론 무선 데이터전송량을 줄이기 위한 방법으로 심전도 데이터에서 심박을 측정한 데이터를 추출하여 보내는데 이것은 개인마다 심전도 신호 세기가 달라서 오차가 생긴다. 본 논문에서는 서로 다른 심전도 세기에 맞추어 심전도를 보정하여 측정할 수 있는 적응형 심박 탐지 모델을 제안한다. 또 제안된 모델을 검증하기 위해, TinyOS 2.0 환경에서 센서 어플리케이션을 설계하고 구현하여 실험을 실시하였다. 실험과정에서 획득한 데이터를 분석함으로써 적응형 심박 탐지모델의 유용성을 평가하였다.

  • PDF

유한 오름 시간을 갖는 음전위 펄스에서 시변환 플라즈마 덮개의 거동 연구 (Measurement of time-dependent sheath for the negative voltage pulse with a finite rise time)

  • 김곤호;김영우;김건우;한승희;홍문표
    • 한국진공학회지
    • /
    • 제8권3B호
    • /
    • pp.361-367
    • /
    • 1999
  • It was observed that the time-dependent sheath which was formed around the planar target biased by negatively voltage pulse with a finite rise time in the plasma source ion implantation. F\Results show that the time-dependent sheath consisted of two parts: the ion matrix sheath development during the pulse rise time and the dynamic sheath motion after attaining the full pulse. The ion matrix sheath development which is in proportion to square root of the pulse time and the pulse rise rate over the plasma density but independent of the ion mass. The dynamic sheath propagates with approximately the ion sound speed.

  • PDF

정상 혈압군과 고혈압군에서의 맥파 파라미터 분석에 관한 연구 (Pulse Wave Parameters Changes between Normotensive and Hypertensive Group)

  • 김은근;허현;남기창;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1999-2000
    • /
    • 2008
  • In this study, pulse wave parameters changes were verified between normotensive and hypertensive group. To measure pulse wave in radial artery, non-invasive tonometric pulse wave measurement device (SphygmoCor PX, AtCor, Austrailia) was used. 136 subjects participated in this study. Among 20 parameters, 16 parameters changes were analysed(p < 0.05) between normotensive(n=104) and hypertensive group(n=32). As a results, several parameters related with pulse pressure, reflective pulse wave, systolic and diastolic function of heart showed significant difference between normotensive and hypertensive group.

  • PDF

트랜스포머를 이용한 고전압 펄스 발생 장치의 설계와 측정평가에 관한 연구 (Study for the Design and Measurement of the High Voltage Pulse Generator Using Transformers)

  • 김영주
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.82-86
    • /
    • 2012
  • High-capacity high-voltage pulse generator that can be used for environmental clean-up was developed using transformers. High-voltage pulse is consists of the primary wave and the harmonic wave which are increased as a series circuit using transformers to make pulses. Each transformer has a band-pass characteristics. The output voltage of the pulse width 50[%] was decided. The output voltage of high-voltage pulse generator device was measured as 1.4[kV] (Peak-to-Peak).

마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정 (Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line)

  • 이승엽;신호섭;김남;권원현
    • 한국통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF