• Title/Summary/Keyword: Pulse Frequency

Search Result 1,951, Processing Time 0.03 seconds

Development of Low Frequency Pulse MIG Welding Process for AL and its alloy (AL 및 AL합금의 저주파 PULSE MIG 용접법의 개발)

  • 최병길;이사영;이승학;천성진
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.45-48
    • /
    • 1997
  • The low frequency pulsed MIG welding process of new current waveform control to switch over unit pulse conditions (pulse current, pulse duration) in the fixed cycle was developed and its effect were investigated for aluminium and its alloy. By using this new welding process, the bead appearance having clear ripple pattern, such as TIG welding bead can be obtained and the gap tolerance of lap and butt welding joint can be expanded.

  • PDF

PWPF Parameters Design for Thruster Control (추력기 제어를 위한 PWPF 설계변수 설계)

  • Kim, Taeseok;Rhee, Seung-Wu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.10
    • /
    • pp.872-880
    • /
    • 2017
  • Usually, on/off control method is a way to control the thruster. Bang-Bang Control, PWM(Pulse Width Modulator) and PWPF(Pulse Width Pulse Frequency) are widely used as a typical way. When we are designing PWPF, the incorrectly designed parameters($K_m$, ${\tau}$, $U_{on}$, $U_{off}$, $U_m$) make trouble, such as the phase lag, the wasted fuel, the reduced system life. Therefore, the effect of parameters on the system performance should be analyzed before the proper parameters are selected. In this paper, we suggest the PWPF parameters design method by performing a static analysis, and analyze the interactive effects on design parameters by performing a dynamic analysis and simulation.

Detection and interpretation of wan-maeck by the pulse diagnostic apparatus -on the pulse/respiration rate- (완맥(緩脈)의 동서의학적(東西醫學的) 해석 -맥율(脈率)을 중심으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Kim, Yong-Suk;Lee, Yun-Ho;Kim, Sung-Woon;Huh, Wung;Youn, Chung-Hwa
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.143-156
    • /
    • 1997
  • This report was conducted to quantify the pulse/respiration ratio and set up the normal range of wan-maeck(緩脈). In order to objectify the pulse diagnosis and use as basic clinical index of Cold-Hot diagnosis, we developed the hardware and software for detection and interpretation of pulse/respiration ratio, pulse/expiration ratio, pulse/respiration ratio, inspiration time, expiration time, respiration frequency, respiration time, duration of one pulse and pulse and pulse rate per minute, The results were as follows; pulse/respiration ratio is $4.30{\pm}1.03$ times, pulse/respiration ratio is $1.60{\pm}0.32$ times, pulse/respiration ratio is $2.37{\pm}0.75$ times, inspiration time is $1.35{\pm}0.20$ sec, expiration time is $1.89{\pm}0.39$ sec, respiration frequency is $17.16{\pm}3.49$ times/min, total respiration time is $3.63{\pm}0.71$ sec, duration of a pulse is $0.86{\pm}0.15$ sec, pulse rate is $71.51{\pm}12.30$ times/min.

  • PDF

Efficiency Improvement of Microwave Oven Using a Pulse Power Supply Embedded HVC-High Frequency Transformer (HVC-고주파변압기 내장형 펄스전원장치를 이용한 Microwave Oven의 효율 향상)

  • 정병환;조준석;강병희;목형수;최규하
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.180-187
    • /
    • 2004
  • A conventional power supply of a microwave oven has a 60Hz transformer and high voltage capacitor(HVC). Though it is very simple and has low cost, it has several problems such as large size, heavy weight and low efficiency To improve these problems, various high frequency inverter type power supply have been investigated and developed in recent years. But these cost is higher than the conventional one due to additional control circuit, fast switching devces. In this paper, a novel pulse power supply for microwave oven using high frequency transformer embedded HVC(High Voltage Capacitor) is proposed for down-sizing, cost reduction and efficient improvement. To verify the effectiveness of the proposed transformer, an equivalent circuit of transformer embedded HVC is derived and it's characteristic is described. And the validity of the proposed pulse power supply embedded HVC-high frequency transformer is shown by simulations and experiments accroding to various operating conditions.

A 40-W Flyback Converter with Dual-Operation Modes for Improved Light Load Efficiency

  • Kang, Jin-Gyu;Park, Jeongpyo;Gong, Jung-Chul;Yoo, Changsik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.4
    • /
    • pp.493-500
    • /
    • 2015
  • A flyback converter operates with either pulse width modulation (PWM) or pulse frequency modulation (PFM) control scheme depending on the load current. At light load condition, PFM control is employed to reduce the switching frequency and thereby minimize the switching power loss. For heavier load, PWM control is used to regulate the output voltage of the flyback converter. The flyback controller has been implemented in a $0.35{\mu}m$ BCDMOS process and applied to a 40-W flyback converter. The light-load power efficiency of the flyback converter is improved up to 5.7-% comparing with the one operating with a fixed switching frequency.

Plasma Characteristics and Substrate Temperature Change in Al:ZnO Pulse Sputter Deposition: Effects of Frequency (Al:ZnO의 펄스 스퍼터 증착에서 주파수에 따른 플라즈마의 특성과 기판 온도 변화)

  • Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.5
    • /
    • pp.209-213
    • /
    • 2007
  • Change of the plasma volume by pulse frequency in a bipolar pulsed DC unbalanced magnetron sputtering was investigated. As increasing the frequency at off duty 10% and at a constant power, the plasma volume was lengthened in vertical direction from the AZO target. When there is an electrically floated substrate, the vertical length of the plasma area was not affected by the pulse frequency. Instead, the diameter of the plasma volume was increased. We found that the temperature rise of a substrate was affected by the pulse frequency, too. As increasing it, the maximum temperature rise of a glass substrate was decreased from $132^{\circ}C\;to\;108^{\circ}C$.

Theoretical Study of Pulse Circuits with the Load Variation for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 관한 부하의 변화를 고려한 펄스회로의 이론적 연구)

  • Kim, Young-Ju;Bang, Sang-Seok;Lee, Chae-Han;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.106-112
    • /
    • 2016
  • The high-voltage pulse generator consists of transformers of fundamental wave and harmonic waves, and shunt capacitors. The pulse has the fundamental wave and the harmonic waves that have been as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed by using transformer equivalent circuits with the effect of load and simulated in time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 2.0kV. In high voltage circuit, capacitors are related to frequency band pass characteristics. Also, it is shown that the voltage of output pulse increases according to the growth of load.

An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability (샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향)

  • Yang, Yoon La;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

A Study on the Way of Pulse-diagnosis by Dongeuibogam (동의보감(東醫寶鑑)중 맥법(脈法)에 관한 연구(硏究))

  • Joo, Shin-Tak;Kim, Jung-Guk;Park, Won-Hwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.1
    • /
    • pp.1-28
    • /
    • 2011
  • Objectives: A study on the importance and consistency of pulse-daignosis in the Dongeuibogam Methods: We used Deyeuk Dongeuibogam of Dongeuibogam publishing company from original photographic edition. Results: The frequency of 27 mek (pulse condition) in Dongeuibogam is as in the following. Bumek (Floating pulse) appeared 120(8.9%) times, wanmek (moderate pulse) appeared 28(2%) times, chokmek (running pulse) appeared 7 (0.5%) times, gyumek (hollow pulse) appeared 19 (1.4%) times, saekmek (uneven pulse) appeared 33 (2.4%) times, sapmek (uneven pulse) appeared 51 (3.8%) times, kyulmek (knotted pulse) appeared 18 (1.3%) times, whalmek (slippery pulse) appeared 69 (5.1%) times, chimek (slow pulse) appeared 43 (3.2%) times, demek (intermittent pulse) appeared 13 (1%) times, silmek (replete pulse) appeared 45 (3.3%) times, bokmek (deep-sited pulse) appeared 29 (2.1%) times, neomek (firm pulse) appeared 4 (0.3%) times, hyunmek (taut pulse) appeared 110 (8.1%) times, yumek (soft pulse) appeared 20 (1.5%) times, dongmek (short and rapid pulse) appeared 16 (1.2%) times, kinmek (tense pulse) appeared 67 (5%) times, yakmek (weak pulse) appeared 46 (3.4%) times, semek (thready pulse) appeared 62 (4.6%) times, hongmek (full pulse) appeared 50 (3.7%) times, jangmek (long pulse) appeared 14 (1%) times, sakmek (rapid pulse) appeared 103 (7.6%) times, mimek (indistinctive pulse) appeared 65 (4.8%) times, danmek (short pulse) appeared 16 (1.2%) times, demek (large pulse) appeared 106 (7.9%) times, chimmek (deep pulse) appeared 112 (8.3%) times, heomek appeared 70 (5.2%) times, sanmek (scattered pulse) appeared 14(1%)times. Conclusions: We can know Donguibogam is given on the basis 27mek (pulse condition), because the frequency of 27mek (pulse condition) is high. But there are another expressions. So we can not say that Donguibogam is consistent in expressing mekbub(the way of pulse-diagnosis).

Chopper Application for Magnetic Stimulation

  • Choi, Sun-Seob;Lee, Sun-Min;Kim, Jun-Hyoung;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.213-220
    • /
    • 2010
  • Since the hypothalamus immediately reacts to a nerve by processing all the information from the human body and the external stimulus being conducted, it performs a significant role in internal secretion; thus, a diverse and rapid stimulus pulse is required. By detecting Zero Detector accurately via the application of AVR on-Chip (ATMEL) using commercial electricity, chopping generates a stimulus pulse to the brain using an IGBT gate to designate a new magnetic stimulation following treatment and diagnosis. To simplify and generate a diverse range of stimuli for the brain, chopping can be used as a free magnetic stimulator. Then, commercial frequency (60Hz) is chopped precisely at the first level of the leakage transformer to deliver an appropriate stimulus pulse towards the hypothalamus when necessary. Discharge becomes stable, and the chopping frequency and duty-ratio provide variety after authorizing a high-pressure chopping voltage at the second level of the magnetic stimulator. These methods have several aims. The first is to apply a variable stimulus pulse via accurate switching frequency control by a voltaic pulse or a pulse repetition rate, according to the diagnostic purpose for a given hypothalamus. Consequently, the efficiency tends to increase. This experiment was conducted at a maximum of 210 W, a magnetic induced amplitude of 0.1~2.5 Tesla, a pulse duration of $200{\sim}350\;{\mu}s$, magnetic inducement of 5 Hz, stimulus frequency of 0.1~60 Hz, and a duration of stimulus train of 1~10 sec.