• Title/Summary/Keyword: Pulse Echo

Search Result 314, Processing Time 0.022 seconds

An Efficient Ultrasonic SAFT Imaging for Pulse-Echo Immersion Testing

  • Hu, Hongwei;Jeong, Hyunjo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.84-90
    • /
    • 2017
  • An ultrasonic synthetic aperture focusing technique (SAFT) using a root mean square (RMS) velocity model is proposed for pulse-echo immersion testing to improve the computational efficiency. Considering the immersion ultrasonic testing of a steel block as an example, three kinds of imaging were studied (B-Scan, SAFT imaging based on ray tracing technology and RMS velocity). The experimental results show that two kinds of SAFT imaging have almost the same imaging performance, while the efficiency of RMS velocity SAFT imaging is almost 25 times greater than the SAFT based on Snell's law.

A Study on the Ultrasonic Technique for Measurement of Vibration in Journal Bearing (저어널 베어링의 진동 계측을 위한 초음파 응용 기술에 관한 연구)

  • 김노유
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.476-481
    • /
    • 1999
  • This paper describes a new technique for measurement of the displacement less than one-quarter of the wavelength of ultrasonic wave using ultrasonic pulse-echo method. The technique determines the displacement of a journal bearing from the amplitudes of the total reflected waves from the surface of journal inside the bearing. Vibration of journal bearing can be measured without using a very high frequency ultrasonic transduce over 100MHz which must be used in the conventional techniques for the precision measurement of a small displacement. The method also requires no inversion process to extract the thickness from the waveforms of the reflected waves, so that it makes possible on-line measurement of the vibration of journal bearing.

  • PDF

Characteristics Evaluation for a PZT Transducer with a Cylindrical Rear Surface (원통형 배면체를 갖는 PZT 트랜스듀서의 특성평가)

  • Kim, Dong-Hyun;Han, Jin-Ho;Yang, Jeong-Won;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1E
    • /
    • pp.14-20
    • /
    • 2007
  • The characteristics of a PZT transducer with a cylindrical rear surface were investigated theoretically and experimentally. The transducer was assumed as a set of finite rectangular ceramic elements for applying the staircase model to the theoretical analysis and the KLM equivalent circuit model was modified for analyzing its electric impedance and pulse-echo response. All results were compared with those of a conventional plane transducer which has a constant thickness of average value for the cylindrical arc. It was noted that the transducer with a cylindrical rear surface has several subsidiary resonant frequencies which are able to widen bandwidth.

Magnetic field Inhomogeneity measurement algorithm using magnetic resonance (자기 공명 영상을 이용한 불균일 자계 측정 알고리즘)

  • Kim, H.J.;Kim, C.Y.;Han, S.Y.;Yoon, J.H.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2809-2811
    • /
    • 1999
  • In this paper, we develope an algorithm to calculate field inhomogeneity in MR imaging using a dual fast spin echo pulse sequence. Because phase modulation time can be easily modified with this pulse sequence, high resolution image can be obtained and acquisition time can be reduced compared to gradient echo technique. In the case of phase wrapping in field map, phase corrected using image processing technique. We assume the field pattern to be second order polynomial and apply Pseudo-Inverse equation to calculate second order polynomial coefficients. These coefficients can be used for the shimming of the magnetic field.

  • PDF

Quantitative Nondestructive Evaluation of Bonded Joints utilizing Pulse-Echo Ultrasonic Test (펄스-에코법을 이용한 접착접합 시험편의 정량적 비파괴 평가)

  • Oh, Seung-Kyu;Hwang, Young-Taek;Lee, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.157-164
    • /
    • 2003
  • The pulse-echo method is one of the most widely used ultrasonic techniques for application of nondestructive evaluation. Particularly, quantitative nondestructive evaluation of defects has been considered more important to assure the reliability and the safety of structure. Frequency energy in adhesive joints is based on the ultrasonic wave analysis. The attenuation coefficient upon wave amplitude and the frequency energy that is expressed in the term of wave pressure amplitude were utilized for the primary wave experiment. By means of a control experiment, it was confirmed that the variation of the frequency energy in adhesive joints depends on transition by stress variation. In this paper, the ultrasonic characteristics were measured for single lap joint and Double Cantilever Beam specimen with different fracture modes that was subjected to stress. Consequently, the data that was obtained from the adhesive specimen was analytically compared to the fracture mechanics parameter

SCALE MODEL EXPERIMENTS FOR ECHO PHENOMENA OF YINGYING PAGODA

  • Chen, Hsiao;Chen, Tong
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.791-795
    • /
    • 1994
  • In this paper, the echo phenomena of Yingying Pagoda(ancient Chinese architecture), which may be resulted from interferences of reflection and diffraction by the pagoda eaves when pulse sound source is at some suitable positions, are investigated by an 1:2 scale model. There are valleys in frequency spectrum due to the interferences. On the other hand, taking eaves as wedges approximately, numerical spectral estimates are obtained from the closed-form impulse solution for diffraction of pulse point-source radiation by an infinite rigid wedge. The results of the numerical computations are similar to those of the model experiments. The study is a helpful guide to reconstruction or maintenance of this kind of ancient buildings.

  • PDF

Comparison of Acoustic Attenuation Measurement Technique of Polyethylene Matrix Composite Materials (폴리에틸렌기재 복합재료의 음향감쇠 측정방법 비교)

  • Kim Kyongsub;Jung Hyun K.;Lee Zin-Hyoung;Hong Soon H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.265-268
    • /
    • 1999
  • 감쇠가 큰 고분자 복합재료에서 초음파 다중반사파를 이용한 Pulse Echo법, 공진주파수에서 내부마찰계수 측정법과 Rheometer를 이용한 동적탄성계수 측정법을 사용하여 음향감쇠계수를 측정하고 각각의 측정자료를 비교하는 연구를 수행하였다. Pulse Echo법을 이용하여 0.5, 1.0, 2.25MHz에서 음향감쇠계수를 측정하였고, 이때 폴리에틸렌기지 복합재료의 음향감쇠계수는 강화재의 부피분율에 따라 3-15dB/cm 정도로 큰 값을 나타내었다. 폴리에틸렌기지 복합재료를 600kHz 근처에서 공진주파수를 가지도록 시편을 만든 후에 내부마찰계수를 측정한 결과로 계산된 음향감쇠계수는 Pulse Echo 실험에서 구한 값과 잘 일치하는 결과를 얻을 수 있었다. Rheometer를 이용한 동적탄성계수 측정법은 0.1-100Hz의 주파수에서 측정한 자료를 TTSP 이론을 이용하여 1MHz의 결과와 비교하였는데, 단일 고분자 재료에서는 다른 측정방법과 음향감쇠계수가 일치하였지만 복합재료에서는 음향감쇠계수값이 일치하지 않는 결과를 나타내었다.

  • PDF

Physics of Harmonic Imaging (하모닉 영상의 물리학)

  • Choi, Min Joo;Yang, Jeong Hwa;Paeng, Dong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.564-572
    • /
    • 2012
  • Harmonic imaging is introduced in the present article and its principle and physical characteristics is described in contrast to conventional ultrasonic imaging. The principle of the conventional image which uses ultrasonic echoes reflected at the interfaces between tissues is presented, and the nonlinear ultrasonic propagation which results in harmonic components is conceptually described. The pulse inversion technique which effectively extracts the harmonic components from the ultrasonic echo signals is introduced, and the advantages of the constructed harmonic images are summarized comparing with those of conventional ultrasonic images. The harmonic images are classified according to the mechanism of harmonic production, and the typical harmonic images obtained from patients are presented in contrast to the corresponding sonograms. Clinical significance and prospects of harmonic imaging and the future research areas are discussed.

Influence of Moisture Content on Longitudinal Wave Velocity in Concrete (수분 함유량이 콘크리트의 종파 속도에 미치는 영향에 관한 연구)

  • Lee, H.K.;Lee, K.M.;Kim, J.S.;Kim, D.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.259-269
    • /
    • 1999
  • Elastic wave velocity measurement technique such as impact-echo method and ultrasonic pulse velocity method has been successfully used to evaluate the moduli and strength of concrete. However, estimation results obtained by the NDT methods do not agree well with real things because longitudinal wave velocity is influenced by various factors. In this paper, among several factors influencing P-wave velocity, the influence of moisture content in concrete was investigated through the experiment. Test results show that longitudinal wave velocity is significantly affected by the moisture content of concrete, i.e., the lower moisture content. the lower velocity. Moisture content influences rod-wave velocity measured by impact-echo method stronger than ultrasonic pulse velocity measured by transmission method. During drying process with ages. the difference of increasing rate between longitudinal wave velocity and compressive strength of concrete is gradually increased. Therefore, to establish more accurate relationship between longitudinal wave velocity and strength, the difference of the increasing rate should be considered.

  • PDF