• 제목/요약/키워드: Pulse Echo

검색결과 314건 처리시간 0.03초

A-Scan 초음파 신호의 시간분해능 향상을 위한 웨이브렛 해석 기반 디컨벌루션 기법 (Wavelet Transform Based Deconvolution for Improvement of Time-Resolution of A-Scan Ultrasonic Signal)

  • 하욥;장경영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.84-89
    • /
    • 2001
  • Ultrasonic pulse echo method comes to be difficult to apply to the multi-layered structure with very thin layer, because the echoes from the top and the bottom of the layer are overlapped. Conventionally method, deconvolution technique has been used for the decomposition of overlapped UT signals, however it has disabilities when the waveform of the transmitted signal is distorted according to the propagation. In this paper, the wavelet transform based deconvolution (WTBD) technique is proposed as a new signal processing method that can decompose the overlapped echo signals in A-Scan signal with superior performances compared to the conventional deconvolution technique. Performances of the proposed method are shown by through computer simulations using model signal with noise and are demonstrated by through experiments for the fabricated acryl rod with a thin steel plate bonded to it.

  • PDF

초음파를 이용한 마멸표면 평가 (Ultrasonic Evaluation of Worn Surface)

  • 안효석;김두인
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제30회 추계학술대회
    • /
    • pp.233-239
    • /
    • 1999
  • The feasibility of an ultrasonic technique using a pulse-echo method of normal-incident compressional waves was evaluated for its sensitivity to the worn surface and near surface damage due to wear. Worn surfaces were generated at various oscillation frequency under a given load and amplitude and these surface were in situ monitored using a ultrasonic wave detection system. Analysis of the ultrasonic waves received from the worn surface revealed a close relationship between the surface and near-surface damage and the maximum echo-amplitude of the compressional waves. The ultrasonic technique was successful in assessing the level of severity of the worn surface in real time during the wear process. It is also shown that the wear depth can be easily measured by the calculation of change of the specimen thickness based on the wave speed measured for the specimen medium.

  • PDF

초음파를 이용한 마멸표면 평가 (Ultrasonic Evaluation of Worn Surface)

  • 안효석;김두인
    • Tribology and Lubricants
    • /
    • 제16권5호
    • /
    • pp.351-356
    • /
    • 2000
  • The feasibility of an ultrasonic technique using a pulse-echo method of normal-incident compressional waves was evaluated for its sensitivity to the worn surface and near surface damage due to wear. Worn surfaces were generated at various oscillation frequency under a given load and amplitude and these surface were in situ monitored using a ultrasonic wave detection system. Analysis of the ultrasonic waves received from the worn surface revealed a close relationship between the surface and near-surface damage and the maximum echo-amplitude of the compressional waves. The ultrasonic technique was successful in assessing the level of severity of the worn surface in real time during the wear process. It is also shown that the wear depth can be easily measured by the calculation of change of the specimen thickness based on the wave speed measured for the specimen medium.

신경회로망을 이용한 철도레일 용접부의 건전성평가 (The Integrity Evaluation of weld zone in railway rails Using Neural Network)

  • 윤인식;임미섭
    • 한국철도학회논문집
    • /
    • 제6권2호
    • /
    • pp.81-86
    • /
    • 2003
  • This study proposes the neural network simulator for the integrity evaluation of weld zone in railway rails. For these purposes, the ultrasonic signals for defects(crack) of weld zone in frames are acquired in the type of time series data and echo strength. The detection of the natural defects in railway truck is performed using the characteristics of echodynamic pattern in ultrasonic signal. And then their applications evaluated feature extraction based on the time-frequency-attractor domain(peak to peak, rise time, rise slope, fall time, fall slope, pulse duration, power spectrum, and bandwidth) and attractor characteristics (fractal dimension and attractor quadrant) etc. The constructed neural network simulator agrees fairly well with the measured results of test block(defect location, beam propagation distance, echo strength, etc). The Proposed neural network simulator in this study can be used for the integrity evaluation of weld zone in railway rails.

초음파 속도법과 충격반향기법에 의한 콘크리트의 종파 속도 비교 (Comparison of Longitudinal Wave Velocity in Concrete by Ultrasonic Pulse Velocity Method and Impact-Echo Method)

  • 이회근;이광명;김영환
    • 비파괴검사학회지
    • /
    • 제23권2호
    • /
    • pp.98-106
    • /
    • 2003
  • 비파괴시험(NDT)은 구조물의 기능에 손상을 주지 않으면서 콘크리트에 대한 많은 정보를 준다. 여러 가지 NDT 방법들 중에서, 초음파 속도법과 충격반향기법과 같이 탄성파의 속도를 이용하는 방법은 콘크리트의 압축강도, 탄성계수, 포아송비의 추정뿐만 아니라, 내부 미세구조 변화 모니터링과 결함 탐지 등을 위해 이용되고 있다. 본 연구에서는 물-결합재비가 $0.27{\sim}0.50$이고 시멘트 중량의 20%를 플라이 애쉬로 대체 사용한 콘크리트를 제조한 후, 동일한 콘크리트에 대해 초음파 속도법과 충격반향기법을 이용하여 종파 속도를 각각 측정하여 서로 비교하였다. 실험 결과, 콘크리트 공시체로부터 측정된 초음파 속도가 충격반향기법에 의해 측정된 종파 속도, 즉 막대파 속도보다 큰 경향을 나타내었으며, 이들의 차이는 재령이 증가함에 따라 그리고 콘크리트의 강도가 커질수록 각각 감소하는 경향을 나타내었다. 또한, 동포아송비, 정탄성계수, 동탄성계수, 속도-강도의 상관관계 등을 실험적으로 결정하였다. 그 결과, 동적인 방법으로 결정되는 포아송비와 탄성계수가 정적인 시험에 의한 것보다 크게 나타났다. 따라서, 탄성파 속도를 이용하여 콘크리트의 성질들을 보다 정확하게 추정하기 위해서는 속도 특성에 대한 이해가 필요할 것으로 사료된다.

림프절의 자기공명영상의 특징: 가토에서 T1과 T2 강조영상의 비교 (Magnetic resonance imaging characteristic of lymph nodes: Comparison of T1 and T2 weighted image in normal rabbits)

  • 이기창;최민철;최호정;윤정희;최승홍;문우경;정진욱
    • 대한수의학회지
    • /
    • 제44권2호
    • /
    • pp.311-315
    • /
    • 2004
  • The detection of lymph node metastasis is an important step in tumor staging and is significant for therapy planning. It has been challenged to yield an appropriate image with diagnostic methods such as Magnetic Resonance (MR) and Computed Tomography (CT). Though CT has been used widely and accessed easily to show internal organs, it can hardly provide difference between lymph node and adjacent vessel or fat tissue. It has been well established that MR can reveal the subtle discrepancy within soft tissue. This study investigated the suitability of MR lymph node imaging without contrast enhancement by comparison of T1-weighted image (T1WI) and T2- weighted image (T2WI) in ten normal rabbits. According to the pulse sequence optimized from preliminary study, T1-weighted spin-echo (repetition time/echo time=400/12 ms) and T-2 weighted fast spin-echo (repetition time/echo time=3500/84 ms) images covering the hind limbs and pelvic region were acquired at 1.5 T. Two radiologists scrupulously evaluated the MR images in consensus. And signal intensity of lymph nodes was compared with that of adjacent fat. Statistical analysis showed that T1-weighted coronal image visualized the lymph nodes (iliac, superficial inguinal and popliteal lymph nodes) quickly and consistently rather than T2-weighted one. Conclusively, T1WI for evaluation of lymph nodes is moderately better than T2WI and appears to have potential for quick and sufficient mapping of the lymph nodes. In addition, this normal MR image of lymph nodes could be applied to further study for the evaluation of lymphatic system in abscess and tumor bearing animal model.

수중 거리 측정을 위한 초음파 센서의 개발 (Development of Ultrasonic Sensor to Measure the Distance in Underwater)

  • 김치효;김태성;정준하;이진형;이민기;장인성;신창주
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2013년도 춘계학술대회
    • /
    • pp.293-298
    • /
    • 2013
  • 본 연구는 수중 거리 측정을 위한 초음파 센서를 개발한다. 초음파 트랜스듀서는 음파를 발신하고 발신된 음파가 물체에 부딪혀 되돌아오는 반사파를 수신한다. 초음파 드라이버는 반사된 물체까지 거리 측정을 위해 음파의 비행시간을 검출해 음속을 곱한다. 본 연구에서는 비행시간을 검출하기 위해 임계값과 상호 상관 기법을 적용하고 그 결과를 보인다. 반사파가 노이즈에 감염되어 신호의 형태가 왜곡될 때 상호상관 기법은 기준 신호와 수신 신호의 유사성을 이용하여 비행시간을 검출한다. 기준 신호를 수중 환경에 따라 다르게 적용해 반사파와 유사성을 높여 센서의 성능을 향상시킨다. 논문에서는 초음파 센서 드라이버를 설명하고 실험환경에 따른 센서의 성능을 분석한다.

  • PDF

초음파 에코파형의 웨이브렛 변환과 비파괴평가에의 응용 (Wavelet Analysis of Ultrasonic Echo Waveform and Application to Nondestructive Evaluation)

  • 박익근;박은수;안형근;권숙인;변재원
    • 비파괴검사학회지
    • /
    • 제20권6호
    • /
    • pp.501-510
    • /
    • 2000
  • 초음파 에코파형의 시간-주파수해석법으로 Wigner 분포와 웨이브렛 변환 등과 같은 새로운 신호처리 기법이 비파괴평가 분야에 널리 응용되고 있다. 본 연구에서는 웨이브렛 변환(wavelet transform)에 의한 음속과 감쇠계수의 주파수의존성과 초음파 결함신호의 잡음제거의 유용성 유무를 실험적으로 검증하였다. Gabor 함수를 웨이브렛의 기본함수로 사용하였다. 초음파의 에코파형에 포함된 각 주파수성분의 속도와 감쇠계수의 주파수의존성을 추정할 수 있었으며, 초음파탐상에서 결함의 검출능 향상과 결함크기 산정의 정량화에 접근하기 위해 웨이브렛 변환에 의한 S/N비 신호처리 시뮬레이션 결과를 오스테나이트강 스테인레스 용접부에 가공한 EDM 노치의 초음파 결함신호에 적용한 결과 임상에코를 저감하고 S/N비를 개선하는 것이 가능하였다.

  • PDF

SWI의 신경영상분야의 임상적 이용 (Clinical Applications of Neuroimaging with Susceptibility Weighted Imaging: Review Article)

  • 노근탁;강현구;김인중
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권4호
    • /
    • pp.290-302
    • /
    • 2014
  • 목적: 자화율 강조 자기공명영상 (Susceptibility-weighted imaging)은 혈액분해산물, 석회화, 철 침착물을 발견하는데 있어 높은 민감도를 보이는 3D spoiled gradient-echo pulse sequence 이다. 본 임상화보는 자화율 강조 자기공명영상의 주된 임상적 적용에 대해 설명하고 논의하는 데에 그 목적이 있다. 대상과 방법: 자화율 강조 자기공명영상은 자기강도영상 (magnitude image)과 위상영상 (phase image)을 이용한 고해상도, 3D fully velocity-compensated gradient-echo sequence 에 기초를 두고 있다. 정맥 구조물의 가시성을 향상시키기 위해, 자기강도영상은 여과된 위상 데이터 (phase data) 로부터 발생된 위상 마스크 (phase mask)를 이용해 증폭되고, 이것은 최소강도투사 (Minimal intensive projection) 알고리즘을 이용한 3D dataset 후처리 과정을 거치게 된다. 3T 자기공명기기에서 SWI를 포함하는 자기공명영상 검사를 시행한 총 200명의 환자를 대상으로 연구하였다. 결과: 자화율 강조 자기공명영상은 다양한 뇌 질환의 발견에 매우 유용하였다. 200명의 환자 중 80명은 선천성 정맥 기형, 22명은 해면상 혈관종, 12명은 다양한 질환에서의 석회화, 21명은 혈관자화 징후 (susceptibility vessel sign) 또는 미세출혈을 동반하는 뇌혈관 질환, 52명은 뇌종양, 2명은 미만성 축삭 손상, 3명은 동정맥 기형, 5명은 뇌경막 동정맥루, 1명은 모야모야병, 그리고 2명은 파킨슨병이 관찰되었다. 결론: 자화율 강조 자기공명영상은 미세 저혈량 혈관성 병변, 석회화 그리고 미세출혈과 다양한 뇌병변의 진단에 유용하다.

프로젝션 타입 고속 스핀 에코 영상 (Projection-type Fast Spin Echo Imaging)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.42-51
    • /
    • 2000
  • 목적: Projection-type Fast Spin Echo (PFSE) 영상 기법은 일반적인 Fast Spin Echo (FSE) 기법과 비교하여 환자의 움직임과 혈류에 강한 장점이 있는 반면. $T_2$ 대조도(contrast)를 조절하기가 어려운 단점이 있다. 본 연구에서는 PFSE의 대조도를 이론적으로 분석하였고 컴퓨터 모의실험을 통하여 다양한 effective echo time (TE) 을 갖는 일반적인 FSE와 비교, 분석하였다. 또한 인체 실험을 통하여 제안한 PFSE 영상기법으로 움직 임과 혈류에 강인한 $T_2$ 강조 영상을 얻을 수 있음을 보였다. 대상 및 방법: 본 연구에서는 1.OT 전신 MRI 시스템에서 새로운 k-space의 배치를 갖는 PFSE 펠스 시권스를 구현하여, PFSE와 FSE 방식의 $T_2$ 대조도를 컴퓨터 모의설험과 인체 실험을 통하여 비교, 분석하였다. 컴퓨터 모의실험에서는 서로 다른 $T_2$ 값을 갖는 팬텀을 구현하여 다양한 effective TE에 대한 FSE 영상과 PFSE 영상을 재구성하여 대조도를 비교하였다. 인체 설험에서는 multi-slice $T_2$ 강조 두부 영상을 PFSE와 FSE로 얻어 영상기법간의 $T_2$ 대조도를 비교하였다. 결과: 이론적인 분석에서 PFSE의 $T_2$ 대조도는 effective TE가 80-l00ms 정도의 FSE 영상과 등가하게 나타나 $T_2$ 강조 영상을 얻을 수 있을 것으로 판단되었다. 컴퓨터 모의실험에서 PFSE 재구성 영상은 effective TE가 96ms인 FSE 영상과 대조도가 비슷하게 나타났다. 인체 실험에 서도 PFSE 영상은 effective TE가 96ms인 FSE 영상과 비슷하게 나타났으며. PFSE 방법이 FSE 방법에 비하여 움직 엄과 혈류와 관련한 artifact에 강인함을 확인 할 수 었었다. 결론: PFSE 기법은 k-space의 극좌표계에서 서로 다른 각도를 갖는 여러 line틀을 다중 스핀 에코 기법으로 측정하는 방식이다. PFSE기법은 FSE와 비교하여 환자의 움직임과 혈류에 강한 장점이 있는 반면, $T_2$ 대조도를 조절하기가 어려운 단점이 있다. 본 연구에서는 PFSE 방식으로 FSE와 대등한 $T_2$ 대조도 ($T_2$ 강조 영상)를 얻을 수 있음을 이론과 컴퓨터 모의실험 밝히고, 인체 실험을 통하여 확인하였다.

  • PDF