• 제목/요약/키워드: Pulse Correction

검색결과 141건 처리시간 0.021초

뜸요법이 전고혈압 성인의 생리적 지수와 자율신경계 증상에 미치는 효과 (Effects of Moxibustion on Physiological Indices and Autonomic Nervous Symptoms in Adults with Prehypertension)

  • 조순희
    • 대한간호학회지
    • /
    • 제40권5호
    • /
    • pp.686-694
    • /
    • 2010
  • Purpose: This study was done to examine the effects of moxibustion on physiological indices, such as 24-hr blood pressure, pulse pressure, and pulse rate, and autonomic nervous symptoms among adults with prehypertension. Methods: Participants were adults whose systolic and diastolic blood pressures were in the prehypertension stage and were not under treatment for the condition. Both experimental and control group consisted of 13 participants who were taking classes on acupuncture and moxibustion at a private institute. The experimental group received moxibustion once a day for 15 min, at least 5 days a week for 8 weeks. The results were analyzed using $x^2$-test, t-test, Fisher's exact test, Wilcoxon rank sum test and repeated measures ANOVA with the SAS program. Bonferroni correction method was adopted for multiple comparisons. Results: No significant change was observed in the 24-hr systolic and diastolic blood pressure between the two groups. Differences in the 24-hr pulse pressure and pulse rate were also not significant. However, significant decreases in headache, symptoms of flushing and fatigue were observed in the experimental group. Conclusion: The results suggest that moxibustion contributes to alleviating symptoms such as headache, flushing and fatigue associated with the autonomic nervous system among adults with prehypertension.

Modeling of 18-Pulse STATCOM for Power System Applications

  • Singh, Bhim;Saha, R.
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.146-158
    • /
    • 2007
  • A multi-pulse GTO based voltage source converter (VSC) topology together with a fundamental frequency switching mode of gate control is a mature technology being widely used in static synchronous compensators (STATCOMs). The present practice in utility/industry is to employ a high number of pulses in the STATCOM, preferably a 48-pulse along with matching components of magnetics for dynamic reactive power compensation, voltage regulation, etc. in electrical networks. With an increase in the pulse order, need of power electronic devices and inter-facing magnetic apparatus increases multi-fold to achieve a desired operating performance. In this paper, a competitive topology with a fewer number of devices and reduced magnetics is evolved to develop an 18-pulse, 2-level $\pm$ 100MVAR STATCOM in which a GTO-VSC device is operated at fundamental frequency switching gate control. The inter-facing magnetics topology is conceptualized in two stages and with this harmonics distortion in the network is minimized to permissible IEEE-519 standard limits. This compensator is modeled, designed and simulated by a SimPowerSystems tool box in MATLAB platform and is tested for voltage regulation and power factor correction in power systems. The operating characteristics corresponding to steady state and dynamic operating conditions show an acceptable performance.

Interleaved Boost-Flyback Converter with Boundary Conduction Mode for Power Factor Correction

  • Lin, Bor-Ren;Chien, Chih-Cheng
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.708-714
    • /
    • 2012
  • This paper presents a new interleaved pulse-width modulation (PWM) boost-flyback converter to achieve power factor correction (PFC) and regulate DC bus voltage. The adopted boost-flyback converter has a high voltage conversion ratio to overcome the limit of conventional boost or buck-boost converter with narrow turn-off period. The proposed converter has wide turn-off period compared with a conventional boost converter. Thus, the higher output voltage can be achieved in the proposed converter. The interleaved PWM can further reduce the input and output ripple currents such that the sizes of inductor and capacitor are reduced. Since boundary conduction mode (BCM) is adopted to achieve power factor correction, power switches are turned on at zero current switching (ZCS) and switching losses are reduced. The circuit configuration, principle operation, system analysis, and design consideration of the proposed converter are presented in detail. Finally, experiments conducted on a laboratory prototype rated at 500W were presented to verify the effectiveness of the converter.

고온고압 세라믹 여과재 탈진 과정의 유동 해석 (Analysis for the Pulse-Jet Cleaning Flow of a Hot Gas Ceramic-Filter Element)

  • 박인욱;류제형;최도형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 춘계 학술대회논문집
    • /
    • pp.110-115
    • /
    • 1998
  • An axisymmetric Navier-Stokes procedure has been developed to analyze the pulse jet flow in a ceramic filter unit for the dust dislodging process. Using Baldwin-Lomax turbulence model as a closure relationship, the SIAF(Scalar Implicit Approximate Factorization) algorithm together with the ${\delta}^k-Correction$ iterative time marching scheme is adopted to solve the unsteady compressible Navier-Stokes equations. After some validation tests, the code has been applied to solve the pulse jet flow and examine the effects of geometry and reservoir pressure condition on the pressure level inside the filter unit. To avoid dealing with the uncertainty of such factors as the cohesion of the collected dust and the adhesion of the dust to the medium and also to simplify the analysis, the filter wall is assumed to be impermeable. The results for various test cases are presented.

  • PDF

방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구 (A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis)

  • 황인구;권기춘;송순자
    • Nuclear Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.784-791
    • /
    • 1995
  • 방사선계측에서는 방사선검출기(detector)로부터 나오는 pulse를 처리하는 데 있어서 pulse의 counting 손실이 발생한다. 이 손실을 최소화하거나 보상하기 위한 여러가지 방법들이 제시되어 왔으나, 아직도 절대적인 해답이 확립되지 않은 실정이다. 본 연구에서는 기 제시된 보상알고리즘들을 그 기능을 구현하는 전자회로와 함께 기술하고 특징을 분석하였다. 또한 본 연구를 통해 pulse의 counting손실을 보상하는 한가지 알고리즘 개선방향을 제시하였다.

  • PDF

PV모듈 발전성능 비교시험과 계측편차 요인 분석 (Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module)

  • 강기환;김경수;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

풀 컬러 LED 디스플레이용 16-채널 LED 드라이버 IC에 관한 연구 (A Study on 16-Channel LED Driver IC for Full-Color LED Display)

  • 김상규;이지훈;정원재;정효빈;박준석
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1275-1282
    • /
    • 2012
  • This paper proposes the 16-channel LED Driver IC for Full color LED display system. The proposed LED driver IC in this paper can draw current independent of temperature and supply voltage in each channel. Current flow in the channel is configurable via an external resistor. LED brightness is adjusted by 12-Bit PWM(Pulse Width Modulation) and 8-Bit DC(Dot Correction). A real-time monitoring of IC temperature ($130^{\circ}C/150^{\circ}C$) and LED status (open/short) is provided by LED driver IC and the user can receive warning and get information on problems. A 16-channel LED driver IC is produced using 0.35 um BCD process and the size is $2.5mm{\times}2.5mm$. In this paper, channel current characteristic and channel current control function were measured in order to verify am embodied 16-channel LED driver IC by producing a single IC test board.

심플한 단상 에어컨의 역률개선회로에 관한 연구 (A Study on Simple Single phase Air-conditioner of Power factor Correction Circuit)

  • 문상필;서기영;이현우;김영문;김영철
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.73-79
    • /
    • 2001
  • 본 논문은 심플한 단상 에어컨의 역률 개선회로에 관해 설명한다. 정류기에 역률제어회로를 적용함에 의해서 전원선으로의 고조파 삽입을 줄일 수 있고, 효율을 향상시킬 수 있으며, 기존의 인버터와 비교해서 전체 시스템 가격을 낮출 수 있다. 또한 역률제어회로의 출력전압을 안정화함에 의해서 시스템 성능을 향상시킨다. 다이오드 정류기의 전류 파형을 향상시키기 위해 전압 다이오드 정류기에 대한 새로운 원리를 제안한다. 제안한 회로의 설계방법은 시뮬레이션과 실험에 의해 확인하였다. 그리고 기존의 펄스폭변조 인버터와 반펄스폭변조 인버터를 비교하였으며, 제안된 HPWM 인버터에 의해서 낮은 스위칭 손실과 오버슈팅을 제어할 수 있다.

  • PDF

Development of a real-time gamma camera for high radiation fields

  • Minju Lee;Yoonhee Jung;Sang-Han Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.56-63
    • /
    • 2024
  • In high radiation fields, gamma cameras suffer from pulse pile-up, resulting in poor energy resolution, count losses, and image distortion. To overcome this problem, various methods have been introduced to reduce the size of the aperture or pixel, reject the pile-up events, and correct the pile-up events, but these technologies have limitations in terms of mechanical design and real-time processing. The purpose of this study is to develop a real-time gamma camera to evaluate the radioactive contamination in high radiation fields. The gamma camera is composed of a pinhole collimator, NaI(Tl) scintillator, position sensitive photomultiplier (PSPMT), signal processing board, and data acquisition (DAQ). The pulse pile-up is corrected in real-time with a field programmable gate array (FPGA) using the start time correction (STC) method. The STC method corrects the amplitude of the pile-up event by correcting the time at the start point of the pile-up event. The performance of the gamma camera was evaluated using a high dose rate 137Cs source. For pulse pile-up ratios (PPRs) of 0.45 and 0.30, the energy resolution improved by 61.5 and 20.3%, respectively. In addition, the image artifacts in the 137Cs radioisotope image due to pile-up were reduced.