• Title/Summary/Keyword: Pulse Analyzer

Search Result 152, Processing Time 0.03 seconds

Implementation of Power Line MODEM for TDC Pulse Detection of SEPA

  • Yang, Hyun-Suk;Lee, Byung-Yong;Kim, Yoon-Sik;Seo, Dong-Hoan;Kim, Sung-Hwan;Kwon, Yeong-Gwal;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.430-436
    • /
    • 2008
  • Recently, there are many cases to use a ship's engine performance analyzer(SEPA) to measure pressure in cylinder and top dead center(TDC) of piston of engine, and analyze its performance such as fuel injection time and horsepower as well as wear of piston ring. But, SEPA needs TDC pulses($T(1){\sim}T(n)$) generated when pistons of engine are located to the TDC position ($TDC(1){\sim}TDC(n)$), these pulses are gathered from sensors connected to gear wheel of the propeller shaft in the remote distance from the measurement point. Therefore, operators need a long wire cable(WRC) to TDC detecting sensor to get these pulses, but this method is a very uncomfortable and expensive in case of installation, and it might decrease user's purchase desire. In this paper, we design and fabricate a small and inexpensive MODEM cable(M0C) so that it may be available to transmit TDC pulse generated from sensor in propeller shaft through existing power line. We also verify the facts that this MOC can be applied to SEPA and the effectiveness of the system through the experiments.

Periodic Mixed Waveform Measurement Techniques for Compact Radar Transmitter with Phase-Continuous Signal (소형 레이더 송신기의 연속 위상을 갖는 주기성 혼합 파형 측정 기법)

  • Kim, So-Su;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.661-670
    • /
    • 2013
  • In this paper, we propose the measurement techniques of mixed waveform. Mixed waveform has phase-continuous periodic waveform with fixed frequency signal and Linear Frequency Modulation(LFM) signal. This waveform is generated from a compact radar transmitter with frequency synthesizer and high power amplifier. Frequency synthesizer generates various signal waveform with continuos phase and high power amplifier amplify transmitting signal. First, we describe a compact radar transmitter with the phase-continuos signal and then verify the distortion characteristic of pulse compression by the mismatch of LFM waveform. Second, we describe three kinds of measurement techniques for measuring LFM waveform. These techniques include methods using signal analyzer, signal source analyzer and new methods using RF mixer and phase shifter. Finally, we verify the accuracy of the measurement technique from the pulse compression result of receiving signal.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

The Effect of Electrical Stimulation of Body Composition in Obese Person (전기자극이 체성분에 미치는 효과)

  • Kim, Yong-Seong;Bang, Sang-Bun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • The purpose of this study is to reveal the effect of electrical stimulation of body composition in obese person. Subjects were 30s to 40s aged healthy workers(2004. 3. 8~4. 17) in the S general Hospital in Suwon and they were brought to manage obesity. Subjects were divided into control group(Female<0.85, Male<0.90) and study group(Female>0.85, Male>0.90) by WHR(waist-hip ratio) that is measured by Automatic body composition analyzer(InBody 3.0). And we divided the study group with randomized methods into group A(n=8) and group B(n=8). Then we compared and analyzed the change of muscle mass, body fat, abdominal girth, WHR, BMI(body mass index) after application of electrical stimulation, three times a week, for 30 minutes in each session with 50 Hz of pulse frequency, $20\;{\mu}s$ or $250\;{\mu}s$ of pulse duration. There was statistically meaningful decrement of body fat(p<0.05) and abdominal girth(p<0.05) but not of body weight, muscle mass, WHR and BMI in the control group after application of electrical stimulation with 50 Hz, $20\;{\mu}s$. There were meaningful change of abdominal girth(p<0.05), WHR(p<0.05) and BMI(p<0.05), but not of body weight, muscle mass and body fat after application of electrical stimulation with 50 Hz, $20\;{\mu}s$ in group A. We applied electrical stimulation with 50 Hz, $250\;{\mu}s$ in group B, then there were meaningful change of body weight(p<0.05), body fat(p<0.01), abdominal girth(p<0.01), WHR(p<0.05) and BMI(p<0.01) but not of muscle mass only. Consequently, the pulse duration is the main parameter of electrical stimulation that affect the body composition of obese person in this study and if we combined the diet control to reduce blood components we could have better result. So it would be more effective to manage localized obesity(in abdomen, thigh, upper arm, etc.) if you apply electrical stimulation considering the pulse duration.

  • PDF

A novel approach in voltage transient technique for the measurement of electron mobility and mobility-lifetime product in CdZnTe detectors

  • Yucel, H.;Birgul, O.;Uyar, E.;Cubukcu, S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.731-737
    • /
    • 2019
  • In this study, a new measurement method based on voltage transients in CdZnTe detectors response to low energy photon irradiations is applied to measure the electron mobility (${\mu}_e$) and electron mobility-lifetime product $({\mu}{\tau})_e$ in a CdZnTe detector. In the proposed method, the pulse rise times are derived from low energy photon response to 59.5 keV($^{241}Am$), 88 keV($^{109}Cd$) and 122 keV($^{57}Co$) ${\gamma}-rays$ for the irradiation of the cathode surface at each detector for different bias voltages. The electron $({\mu}{\tau})_e$ product was then determined by measuring the variation in the photopeak amplitude as a function of bias voltage at a given photon energy using a pulse-height analyzer. The $({\mu}{\tau})_e$ values were found to be $(9.6{\pm}1.4){\times}10^{-3}cm^2V^{-1}$ for $1000mm^3$, $(8.4{\pm}1.6){\times}10^{-3}cm^2V^{-1}$ for $1687.5mm^3$ and $(7.6{\pm}1.1){\times}10^{-3}cm^2V^{-1}$ for $2250mm^3$ CdZnTe detectors. Those results were then compared with the literature $({\mu}{\tau})_e$ values for CdZnTe detectors. The present results indicate that, the electron mobility ${\mu}_e$ and electron $({\mu}{\tau})_e$ values in CdZnTe detectors can be measured easily by applying voltage transients response to low energy photons, utilizing a fast signal acquisition and data reduction and evaluation.

Excimer laser annealing of sol-gel derived PZT thin films

  • Do, Young-Ho;Kang, Min-Gyu;Oh, Seung-Min;Kang, Chong-Yun;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.20-20
    • /
    • 2010
  • The effect of excimer laser annealing on the structural and dielectric behaviors of $PbZr_{0.52}Ti_{0.48}O_3$ (PZT) thin films has been investigated. The amorphous PZT thin films were prepared on Pt/Ti/$SiO_2$/Si substrates by a sol-gel method. The PZT precursor was prepared from lead acetate, zirconium acetylacetonate, and titanium isopropoxide. The starting materials were dissolved in n-propanol and 1,3-propanediol. After, the amorphous PZT thin films were laser-annealed (using KrF excimer laser) as a function of the laser energy density and the number of laser pulse. Structural properties of PZT thin films are characterized by using X-ray diffraction (XRD) and scanning electron microscopy (SEM). The dielectric characterization was done on a RT66A test system and a Agilent 4294A impedance analyzer. The PZT thin films show that excimer laser irradiation drastically improved the crystallization and dielectric properties of the PZT thin films, depending on the energy density and the pulse number.

  • PDF

A Study on the Method of Nonlinearity Correction in a GM Counter

  • Ha, Chung-Woo;Yook, Chong-Chul;Philip S. Moon
    • Nuclear Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.137-144
    • /
    • 1978
  • A method is presented here in order to determine a nonlinearity correction of observed counter rates in a GM counter. An expression, which is developed under the assumption of dead time dependence on counting rates, gives good agreement with the results obtained from the experimental work. The variation of pulse voltages from a GM counter with counting rates was measured with the aid of pulse height analyzer. This method gives accurate values for the dead time over a wide range of counting. The technique as outlined allows tile exact correction of the nonlinearity caused by dead time loss. It was observed that the dead time decreases as the counting rate increases.

  • PDF

Photo-induced Electrical Properties of Metal-oxide Nanocrystal Memory Devices

  • Lee, Dong-Uk;Cho, Seong-Gook;Kim, Eun-Kyu;Kim, Young-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.254-254
    • /
    • 2011
  • The memories with nano-particles are very attractive because they are promising candidates for low operating voltage, long retention time and fast program/erase speed. In recent, various nano-floating gate memories with metal-oxide nanocrystals embedded in organic and inorganic layers have been reported. Because of the carrier generation in semiconductor, induced photon pulse enhanced the program/erase speed of memory device. We studied photo-induced electrical properties of these metal-oxide nanocrystal memory devices. At first, 2~10-nm-thick Sn and In metals were deposited by using thermal evaporation onto Si wafer including a channel with $n^+$ poly-Si source/drain in which the length and width are 10 ${\mu}m$ each. Then, a poly-amic-acid (PAA) was spin coated on the deposited Sn film. The PAA precursor used in this study was prepared by dissolving biphenyl-tetracarboxylic dianhydride-phenylene diamine (BPDA-PDA) commercial polyamic acid in N-methyl-2-pyrrolidon (NMP). Then the samples were cured at 400$^{\circ}C$ for 1 hour in N atmosphere after drying at 135$^{\circ}C$ for 30 min through rapid thermal annealing. The deposition of aluminum layer with thickness of 200 nm was followed by using a thermal evaporator, and then the gate electrode was defined by photolithography and etching. The electrical properties were measured at room temperature using an HP4156a precision semiconductor parameter analyzer and an Agilent 81101A pulse generator. Also, the optical pulse for the study on photo-induced electrical properties was applied by Xeon lamp light source and a monochromator system.

  • PDF

A Study about Correlations between the Interpretations of Autonomic Bioelectric Response Recorder (ABR-2000) and Diagnosis System of Oriental Medicine (DSOM) / 3D Blood Pressure Pulse Analyzer (3D-MAC) (생체전기자율반응 측정기와 한방진단시스템 및 맥진기 검사 해석의 상관성 연구)

  • Ok, Jin-Yoo;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.2
    • /
    • pp.31-48
    • /
    • 2018
  • Objectives: This study was performed to observe the correlations between the results of ABR-2000 and DSOM / 3D-MAC to evaluate the feasibility of ABR-2000 as a oriental medical diagnostic criteria. Methods: We studied 547 women visiting ${\bigcirc}{\bigcirc}$ hospital from December 2012 to June 2015. The subjects were categorized in two groups, 'Hypotonia' and 'Non-Hypotonia' by the result of ABR-2000 and assessed the result of DSOM, 3D-MAC for each group. The differences of pulse wave factors by group also studied. Results: 1. There was no significant difference between two groups about the output frequency of pathogenic factors in DSOM while the result showed the higher correlation in Hypotonia group in terms of the companion tendency of pathogenic factors and syndromes formed by the combination of pathogenic factors. 2. The pulse waves of Hypotonia group were mostly slow, weak, tense and stiff than Non-Hypotonia group. Conclusions: 1. In Hypotonia group, yin deficiency (陰虛) factor was frequently accompanied and consumption (虛損) of various organs based on the yin deficiency (陰虛) was observed. It means chronic and severe condition of exhaustion syndrome (虛勞). 2. The result of 3D-MAC also means pathological feature of yin syndrome (陰 證) and consumption (虛損). Besides, lower scores of Body Surface Area (BSA), body weight, and Body Mass Index (BMI) were associated with body weakness (體瘦), a symptom of exhaustion syndrome (虛勞).

Comparison of Arterial Oxygen Saturation Measured by Pulse Oximetry at Different Sensor Sites in Neurocritical Patients (신경계 중환자의 측정부위별 맥박 산소포화도의 비교)

  • Jeon, Min-Jeong;Hwang, Sun-Kyung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : This study aimed to compare peripheral pulse oxygen saturation (SpO2) values, measured at different monitoring sites, and arterial oxygen saturation (SaO2) of neurocritical patients. Methods : The study included 110 patients admitted to the neurosurgical intensive care unit of a university hospital. The patients' SpO2 values were measured in their index fingers, both second toes, both earlobes, and foreheads, using the patient monitoring system. These values were compared with the standard value of SaO2 measured using a blood gas analyzer. Data were analyzed using descriptive values, Pearson's correlation coefficients, Lin's concordance correlation coefficients (CCC), and Bland-Altman plots. Result : Regardless of the measuring site, SpO2 was correlated with the paired measurements of SaO2 (r=.40~.60, p<.001, CCC range=.40~.58). No significant bias in paired measurements of SpO2 and SaO2 was observed at all sites (-0.06~0.19%, p>.05). SpO2 values at the left finger and right earlobe had the narrowest range, with a 95% limits of agreement (LOA) (left finger -3.04~2.93% and right earlobe -3.18~2.79%). SpO2 at the index finger, on the side without an arterial catheter, had a narrower range of 95% LOA than that of the opposing finger (-3.00~2.97% vs. -3.73~3.26%). Conclusion : SpO2 at the finger without an arterial catheter had the highest level of precision. This study suggests using the index finger, on the side without an arterial catheter, for pulse oximetry in neurocritical patients.