• Title/Summary/Keyword: Pulsation Flow

Search Result 187, Processing Time 0.022 seconds

Reduction of combustion instability using flame holder integrated injector (통합형 연료분사장치를 통한 연소불안정 저감)

  • Hwang, Yong-Seok;Lee, Jong-Guen;Park, Ik-Soo;Choi, Ho-Jin;Jin, Yu-In;Yoon, Hyun-Gull;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.432-437
    • /
    • 2010
  • A new device injecting secondary fuel behind flameholder was invented and tested in order to reduce low frequency combustion instability of combustor using V-gutter flameholder. Specially designed combustion device could make large combustion instability up to 180 dB successfully, and newly invented device made a success to reduce 110~120Hz low frequency pressure pulsation up to 84%. It was found that the fuel flow rate of secondary fuel supplying behind flameholder was the only parameter which dominates reduction of instability. It is considered that stabilized flame with sufficient secondary fuel can lead to break the connection between combustion system and acoustic system due to independence of flame from fluctuation of main fuel resulted from synchronization with acoustic wave.

  • PDF

Structural Integrity Evaluation of Large Main Steam Piping by Water Hammering (수격 현상에 근거한 대형 주증기관의 구조건전성 평가)

  • Jo, Jong-Hyun;Lee, Young-Shin;Kim, Yeon-Whan;Jin, Hai Lan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1103-1108
    • /
    • 2012
  • A main steam pipe system is a branch pipe that connects a boiler with a turbine. Water hammering analysis is very important for limiting the damage caused to pipe systems by operation conditions. Water hammering created by an unsteady flow in pipeline systems can cause excessive change in pressure, vibration, and noise. The main steam pipe structure should be designed to safely maintain the pressure pulsation and several vibrations under operation environments. This study evaluated the structural integrity of a main steam pipe during suspended and normal operation by using the ASME fatigue life methodology and finite element analysis. In the analysis, water hammering was used for transient analysis. The calculated alternating stress and fatigue stress were compared with the applicable limits of ASME fatigue life. All the evaluation results satisfied the requirements of the ASME fatigue life.

SRM Driving Characteristics through Modeling of Variable Hysteresis Current Control (가변 히스테리시스 전류제어 모델링을 통한 SRM 구동특성)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.123-128
    • /
    • 2022
  • The torque of the SRM((Switched Reluctance Motor)) is proportional to the inductance slope, so it has a non-linear torque characteristic, and has a disadvantage in that the torque pulsation is large and noise is severe. In particular, the biggest obstacle to the commercialization of SRM is the pulsating torque generated from the rotating shaft, which has various adverse effects not only on the device itself but also on the peripheral devices. Therefore, various methods for reducing the pulsating torque have been published by domestic and foreign researchers, and there is a study result that the hysteresis controller has an advantage in that it can flow a smooth current compared to the chopping control. However, in determining the hysteresis band, if the band is too small, it has a disadvantage in that it may cause a switching loss due to many switching and an unstable initial start when the encoder is used. Therefore, in this paper, a variable hysteresis controller that can reduce torque ripple in a steady state while having a more stable and fast speed response through the change of the hysteresis band according to the speed error.

Numerical simulation and experimental study of non-stationary downburst outflow based on wall jet model

  • Yongli Zhong;Yichen Liu;Hua Zhang;Zhitao Yan;Xinpeng Liu;Jun Luo;Kaihong Bai;Feng Li
    • Wind and Structures
    • /
    • v.38 no.2
    • /
    • pp.129-146
    • /
    • 2024
  • Aiming at the problem of non-stationary wind field simulation of downbursts, a non-stationary down-burst generation system was designed by adding a nozzle and program control valve to the inlet of the original wall jet model. The computational fluid dynamics (CFD) method was used to simulate the downburst. Firstly, the two-dimensional (2D) model was used to study the outflow situation, and the database of working conditions was formed. Then the combined superposition of working conditions was carried out to simulate the full-scale measured downburst. The three-dimensional (3D) large eddy simulation (LES) was used for further verification based on this superposition condition. Finally, the wind tunnel test is used to further verify. The results show that after the valve is opened, the wind ve-locity at low altitude increases rapidly, then stays stable, and the wind velocity at each point fluctuates. The velocity of the 2D model matches the wind velocity trend of the measured downburst well. The 3D model matches the measured downburst flow in terms of wind velocity and pulsation characteris-tics. The time-varying mean wind velocity of the wind tunnel test is in better agreement with the meas-ured time-varying mean wind velocity of the downburst. The power spectrum of fluctuating wind ve-locity at different vertical heights for the test condition also agrees well with the von Karman spectrum, and conforms to the "-5/3" law. The vertical profile of the maximum time-varying average wind veloci-ty obtained from the test shows the basic characteristics of the typical wind profile of the downburst. The effectiveness of the downburst generation system is verified.

Pulsatility Index in Different Modifications of Fontan Palliation: An Echocardiographic Assessment

  • Reza Shabanian;Parvin Akbari Asbagh;Abdullah Sedaghat;Minoo Dadkhah;Zahra Esmaeeli;Aliyeh Nikdoost;Manizheh Ahani;Mitra Rahimzadeh;Alireza Dehestan;Mohammad Ali Navabi
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.2
    • /
    • pp.99-108
    • /
    • 2022
  • BACKGROUND: Adding pulsation to the Fontan circulation might change the fate of patients palliated by this procedure. Our aim was to compare the pulsatility index (PI) of the pulmonary artery (PA) between the various modifications of Fontan palliation. METHODS: Doppler-derived PI was measured in PA branches of a cohort of 28 patients palliated by 6 modifications of Fontan procedure. A group of normal individuals was included for comparison. RESULTS: Atriopulmonary connection (APC) group had the highest PA branches PI and statistically was close to the PI of the normal individuals (right pulmonary artery [RPA] PI of 1.58 vs. 1.63; p = 0.99 and left pulmonary artery [LPA] PI of 1.54 vs. 1.68; p = 0.46, respectively). The lowest PA branches PI was seen in the group of extracardiac total cavopulmonary connection (RPA PI of 0.62 and LPA PI of 0.65). Other 4 modifications including the extracardiac conduit with oversewn pulmonary valve, extracardiac conduit with preserved adjusted antegrade flow, extracardiac conduit from inferior vena cava onto the rudimentary right ventricle and lateral tunnel had a mean "RPA and LPA" PI of "1.19 and 1.17", "1.16 and 1.11", "1.13 and 1.11", "0.82 and 0.84", respectively. The modified Dunnett's post hoc test has shown a significant statistical decline in PI of all modifications compared to the normal individuals except for the APC group. CONCLUSIONS: Fontan palliated patients in different groups of surgical modification showed a spectrum of Doppler-derived PI with the highest amounts belong to the groups of pulsatile Fontan.

A Study on Rehabilitation Treatment Using Radiofrequency Treatment (고주파 통증치료기를 이용한 재활 치료에 대한 연구)

  • Jo, Jae-Hyun;Lee, Sang-Yong;Lee, Geun-Yong;Yoon, Se-Jin;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 2020
  • When Radiofrequency energy is applied to the human body, the vibration width is very short. Therefore, the electrolyte burn generated when using the direct current does not occur. Ion molecules, polarized molecules, etc., vibrate more than 40,000 times per second, converting them into frictional heat to generate deep heat. The blood flow of capillaries increases 4-5 times more than at rest, increasing the supply of oxygen, nutrients, antibodies, and white blood cells. In addition, the electrochemical reaction does not occur because the vibration width and the pulsation period are very short. It is a physical factor treatment method that does not stimulate the sensory nerves and motor nerves. In this study, an isotonic exercise is performed in a young normal adult using a Radiofrequency pain treatment device. The purpose of this study is to integrate rehabilitation therapy by measuring electromyography data during isotonic exercise and confirming the effect on changes in motor neuron response. The EMG data generated when isotonic exercise of the forearm biceps muscle and the EMG data measured after the use of a Radiofrequency pain treatment device after exercise were RMS, respectively, and verified through t-test. It was confirmed that there was a significant difference in both men and women because the t-value was smaller than the significance level p (<.05).

Experimental investigation on valve rattle noise of automotive electronic-wastegate turbochargers (차량용 전자식 웨이스트 게이트 터보차져의 밸브 떨림음에 대한 실험적 고찰)

  • Park, Hoil;Eom, Sangbong;Kim, Youngkang;Hwang, Junyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.686-686
    • /
    • 2013
  • Automotive turbochargers have become common in gasoline engines as well as diesel engines. They are excellent devices to effectively increase fuel efficiency and power of the engines, but they unfortunately cause several noise problems. The noises are classified into mechanical noises induced from movement of a rotating shaft and aerodynamic noises by air flow in turbochargers. In addition to, there is a mechanical noise caused from movement of an actuator, electronically controlling a wastegate valve. It is called as valve rattle noise. The actuator is connected to a valve through a linkage. The noise occurs only if the valve is open, where the linkage is freely contact to neighbor structures without being constrained by any external forces. This condition allows impacts by the pulsation of exhaust gas, and the vibration from the impacts spreads out through turbine housing, causing the rattle noise. The noise is not in mechanical operating wastegate turbochargers because the linkage of an actuator is strongly connected by actuating force. For the electronic wastegate turbocharger, this paper proposed a test device to show the noise generating mechanism with a small vibration motor having an unbalanced shaft. It also shows how to reduce the noise - reduction of linkage clearances, inserting wave washers into a connection, and applying loose fitting in bushing embracing a valve lever to turbine housing.

  • PDF