• Title/Summary/Keyword: Pulmonary artery injury

Search Result 47, Processing Time 0.024 seconds

The Change of Antioxidant Enzyme (Superoxide Dismutase, Catalase, Glutathione Peroxidase) in the Endotoxin Infused Rat Lung (내독소 투여후 쥐의 폐조직내 Antioxidant (Superoxide Dismutase, Catalase, GSH-Peroxidase)의 변화에 대한 연구)

  • Song, Jeong-Sup;Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Han, Ki-Don;Moon, Hwa-Sik;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.104-111
    • /
    • 1993
  • Background: Gram-negative bacterial endotoxin induced septicemia is known to be a leading cause in the development of adult respiratory distress syndrome(ARDS). The mechanism of endotoxin induced lung injury is mainly due to the activated neutrophils which injure the capillary endothelial cells by releasing oxidant radical and resulted in pulmonary edema. We studied the change of antioxidant enzyme in the case of large or small, intermittant dose of endotoxin infused rat lungs. Methods: Endotoxin was given to the rat through the peritoneal cavity in the dose of 7 mg/kg body weight in the large dose group and 1 mg/kg for 10 days in the small dose group. Bronchoalveolar lavage (BAL) was done and rats were killed at 6, 12, 24 hours after single endotoxin injection in the large dose group and 3, 7, 10 days after daily endotoxin injection for 10 days in the small dose group. The lungs were perfused with normal saline through the pulmonary artery to remove the blood and were homogenized in 5 volume of 50 mM potassium phosphate buffer containing 0.1 mM EDTA. After centrifuging at 100,000 g for 60 minute, the supernatent was removed and stored at $-70^{\circ}C$ until measuring for superoxide dismutase (SOD), catalase, glutathione peroxidase (GSH-Px) and protein. Results: We observed the following results. 1) The lung wet/dry weight ratio and albumin concentration in the BAL fluids were increased to peak at 12 hours and neutrophil number in the BAL fluids were peak at 6 hours after endotoxin injection in the large dose group. 2) Cu, Zn SOD (IU/mg protein) was significantly decreased after 6, 12 hours after endotoxin injection in the large dose group. 3) There were no singnificant change in the level of Mn SOD, catalase, GSH-Px after endotoxin injection in both groups. Conclusion: Endotoxin in the large dose group produced the acute pulmonary edema and decreased the Cu, Zn SOD in the lung tissue after injecting endotoxin at 6 and 12 hours. These phenomenon may be due to the cell membrane damage by endotoxin. Further research would be necessary whther giving SOD by intratracheal route or method to increase the synthesis of SOD may lessen the acute lung injury by endotoxin.

  • PDF

Early Clinical Outcomes of Tricuspid Valve Repair with a Tri-Ad Annuloplasty Ring in Comparison with the Outcomes Using an MC3 Ring

  • Jung, Woohyun;Choi, Jae Woong;Hwang, Ho Young;Kim, Kyung Hwan
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.92-99
    • /
    • 2018
  • Background: We evaluated the early clinical outcomes of tricuspid valve annuloplasty (TAP) with the Tri-Ad annuloplasty ring for functional tricuspid regurgitation (TR). Methods: From January 2015 to March 2017, 36 patients underwent TAP with a Tri-Ad ring for functional TR. To evaluate the early clinical outcomes of TAP with the Tri-Ad ring, we conducted a propensity score-matched analysis comparing the Tri-Ad and $MC^3$ tricuspid annuloplasty rings (n=34 in each group). The follow-up duration was $11.0{\pm}7.07$ months. Results: There was 1 case of operative mortality (2.8%) and no cases of late mortality. Postoperative complications occurred in 15 patients (41%), including acute kidney injury in 6 patients (16%), bleeding requiring reoperation in 4 patients (11%), and low cardiac output syndrome in 4 patients (11%). There were no ring-related complications, such as atrioventricular block or ring dehiscence. The TR grade decreased significantly (from $2.03{\pm}1.06$ to $1.18{\pm}0.92$, p<0.01), as did the systolic pulmonary artery pressure (from $43.53{\pm}13.84$ to $38.00{\pm}9.72mm\;Hg$, p=0.03). There were no cases of severe residual TR, but moderate TR was observed in 3 patients, all of whom had severe TR preoperatively. Severe preoperative TR was also associated with moderate in the univariate analysis (p<0.01). In the propensity score-matched analysis comparing the Tri-Ad and $MC^3$ rings, there was no significant difference in early clinical outcomes. Conclusion: TAP with the Tri-Ad ring corrected functional TR effectively and provided good early clinical and echocardiographic results without ring-related complications. However, severe preoperative TR was associated with moderate or severe residual TR in the immediate postoperative period. A follow-up study is necessary to confirm the stability of this procedure.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

A Comparison of the Effects of Histidine-tryptophan-ketoglutarate Solution versus Cold Blood Cardioplegic Solution on Myocardial Protection in Mitral Valve Surgery (승모판막수술 시 히스티딘를 함유한 결정성 심정지액(Histidine-tryptophan-ketoglutarate Solution)과 저온 혈성 심정지액이 심근기능 보존에 미치는 영향 비교)

  • Choi, Yong-Seon;Bang, Sou-Ouk;Chang, Byung-Chul;Lee, Sak;Park, Chol-Hee;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.399-406
    • /
    • 2007
  • Background: Ischemia-reperfusion injury related to unsuccessful myocardial protection affects postoperative ventricular function and mortality during open-heart surgery. We prospectively compared the effects of administration of histidine-tryptophan-ketoglutarate (HTK) solution and cold blood cardioplegia (CBC) on myocardial protection and clinical outcome in patients undergoing mitral valve surgery. Material and Method: Seventy patients with mitral regurgitation (MR) undergoing mitral valve surgery were randomly divided into the HTK group (n=31) and the CBC group (n=31 ): eight patients were excluded. Perioperative hemodynamics, cardiac medications, pacing, postoperative outcomes and complications were recorded during the hospital stay. All patients received follow-up for at least 6 months postoperatively for morbidity and mortality. Resuか: There were no significant differences in the hemodynamics between the groups during the study period, except for the mean pulmonary artery pressure (MPAP), PCWP and CVP that were lower in the HTK group at 15 min after weaning of CBP. There were no differences for inotropic support and pacing during the 12 hrs postoperatively between the groups. CK-MB values on day 1 and day 2 were $77{\pm}54$ and $41{\pm}23$ for the HTK group and $70{\pm}69$ and $44{\pm}34$ for the CBC group, respectively (p=NS). Postoperative clinical outcomes were similar in both groups for at least 6 months during the follow-up period. Conclusion: These results suggest that the use of HTK solution is as safe as cold blood cardioplegia in terms of myocardial protection.

One Stage Total Repair of the Aortic Arch Anomaly using the Regional Perfusion (대동맥궁 이상이 동반된 선천성 심장병에서 국소 순환을 이용한 일차 완전 교정)

  • Jang Woo-Sung;Lim Cheong;Lim Hong-Kook;Min Sun-Kyung;Kwak Jae-Kun;Chung Eui-Seuk;Kim Dong-Jin;Kim Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.6 s.263
    • /
    • pp.434-439
    • /
    • 2006
  • Background: Deep hypothermic circulatory arrest during repair of aortic arch anomalies may induce neurological complications or myocardial injury. So we surveyed if the regional cerebral and myocardial perfusion might eliminate those potential side effects. Material and Method: From March 2000 to December 2004, 62 neonates or infants with aortic arch anomaly underwent one stage biventricular repair using the regional perfusion technique by single surgeon. Preoperative diagnosis of the arch anomaly consisted of coarctation (n=46), interruption of the aorta (n=12), hypoplastic left heart syndrome (n=2) and truncus areteriosus (n=2). Combined anomalies were ventricular septal defect (n=51), TAPVR (n=1), PAPVR (n=1) and atrioventricular septal defect (n=2). Arterial cannula was inserted at the innominate artery. Result: The mean regional perfusion time of brain was $28{\pm}10min$. Operative mortality rates was 0 (0/62). Late death was 1 (1/62) during $11{\pm}7$ months of follow-up. Neurologic complications consisted of transient chorea in 1 case. There was no reoperation associated with arch anolamy. Pulmonary complication associated with arch repair occurred in f case which was managed by aortopexy. Conclusion: One-tage rch repair using the regional profusion is safe and effective in minimizing the neurologic and myocardial complications.

Use of Intermittent Antegrade Warm Blood Cardioplegia in CABG (관상동맥 우회로조성술에서 간헐적 전방 온혈 심정지액의 이용)

  • 김정택;백완기;김영삼;윤용한;김혜숙;이춘수;임현경;김현태;김광호
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.828-833
    • /
    • 2003
  • Background: It has been reported that the recently developed intermittent antegrade warm blood cardioplegia (IAWBC) has better myocardial protective effects during coronary artery bypass surgery than cold blood cardioplegia or continuos retrograde cold blood cardioplegia. The aim of this study is to evaluate the safety and usefulness of IAWBC by comparing it retrospectively with intermittent retrograde cold blood cardioplegia (lRCBC). Material and Method: From April 2001 to Feb. 2003, fifty seven patients who underwent isolated coronary surgery were divided into two groups (IAWBC vs. IRCBC). The two group had similar demographic and angiographic characteristics. There were no statistical differences in age, sex, Canadian Cardiovascular Society Functional Classification for angina, ejection fraction, and number of grafts. Result: Aortic cross clamping time and total pump time in IAWBC (99$\pm$23 and vs. 126$\pm$32 min) were shorter than those of IRCBC (118$\pm$32 min. and 185$\pm$48 min.)(p<0.05). The reperfusion time (13$\pm$7 min) in IAWBC was shorter than that of IRCBC (62$\pm$109 min.)(p<0.05). CKMB at 12 hours and 24 hours (16$\pm$15 and 9$\pm$13) in IAWBC was lower than that of IRCBC (33$\pm$47 and 17$\pm$26)(p<0.05). The awakening time in IAWBC (2$\pm$1 hour) was shorter than that of IRCBC (4$\pm$3)(p<0.05). The number of spontaneous heart beat recovery in IAWBC (85%) was more than that of IRCBC (35%)(p<0.05). The cardiac index after discontinuing cardio-pulmonary bypass was significantly elevated in the IAWBC group. The prevalence of perioperative myocardial infarction in IAWBC (4%) was lower than that of IRCBC group (20%)(p<0.05). Conclusion: Intermittent antegrade warm blood cardioplegia is a safe, reliable, and effective technique for myocardial protection. It can also provide simpler and economic way than the retrograde cold cardioplegia by shortening of cardiopulmonary bypass time and avoiding retrograde cannulation for coronary sinus.

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF