• 제목/요약/키워드: Pull-out Tests

검색결과 225건 처리시간 0.026초

Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

  • Karakasli, Ahmet;Acar, Nihat;Uzun, Bora
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.180-185
    • /
    • 2018
  • Objective : Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study is to assess the pull-out strength of lumbosacral screws penetrating the end plate and comparing it to the conventional trans-pedicular screw insertion method. Methods : Eight lumbar and eight sacral vertebrae, with average age 69.4 years, Left pedicles of the 5th lumbar vertebrae were used for trans-endplate screw fixation, group 1A, right pedicles were used for anatomical trans-pedicular screw fixation, group 1B. In the sacral vertebrae, the right side S1 pedicles were used for trans-endplate fixation, group 2A, left side pedicles were used for anatomical trans-pedicular screw fixation, group 2B. The biomechanical tests were performed using the axial compression testing machine. All tests were applied using 2 mm/min traction speed. Results : The average pull-out strength values of groups 1A and 1B were $403.78{\pm}11.71N$ and $306.26{\pm}17.55N$, respectively. A statistical significance was detected with p=0.012. The average pull-out strength values of groups 2A and 2B were $388.73{\pm}17.03N$ and $299.84{\pm}17.52N$, respectively. A statistical significance was detected with p=0.012. Conclusion : The trans-endplate lumbosacral fixation method is a trustable fixation method with a stronger screw-bone purchase and offer a good alternative for surgeons specially in patients with osteoporosis.

비탈면 보강에 적용된 네일강화구 거동 분석 (Analysis on Behavior of Mechanical Bulb (GangWhaGu) Applied to Slope Reinforcement)

  • 정순국;이승호
    • 한국지반환경공학회 논문집
    • /
    • 제17권10호
    • /
    • pp.55-62
    • /
    • 2016
  • 매년 이상기후로 인하여 비탈면 붕괴 빈도는 좀처럼 줄어들지 않고 막대한 인명 및 재산 피해로 연결되어 피해규모도 점차 증가하고 있는 상황이다. 이를 억제하기 위해 기술자들은 보다 나은 보강재를 개선하고 인발력이나 전단력을 향상시키는 노력을 계속하고 있다. 본 연구에서는 쏘일 네일 공법을 발전시킨 것으로 네일 선단에 강화구를 장착하여 인발저항력을 증대하고 네일과 일체된 강화구는 접촉면적을 극대화 시켜 지반-그라우트체간 마찰력을 증대시킴으로써 비탈면 안정에 증가효과를 보인다. 보강효과를 검증하고자 일반적인 쏘일 네일과 강화구 네일의 실내인발시험과 현장실험을 통한 거동 특성과 적용성을 확인하기 위하여 실험을 진행하였다. 실험결과 강화구 네일의 경우 인발시험을 통해 일반 네일의 인장력과 비교하여 약 20% 증가하는 것을 분석하였다.

탄소섬유쉬트와 콘크리트의 부착강도 실험연구 (Experimental Study on Bond Strength between Carbon Fiber Sheet and Concrete)

  • 유영찬;최기선;최근도;이한승;김긍환
    • 콘크리트학회논문집
    • /
    • 제13권2호
    • /
    • pp.168-174
    • /
    • 2001
  • 탄소섬유쉬트는 고강도, 경량 및 고 내구성 등의 우수한 재료적 성질을 가지고 있어 철근콘크리트 건축물의 보수 .보강재료 장범위하게 사용되어져 왔다. 탄소섬유쉬트와 콘크리트 사이의 부착강도 즉, 부착거동은 탄소섬유쉬트에 의해 보수.보강되는 철근콘크리트 부재의 보강성능을 좌우하는 매우 중요한 요소이다. 따라서, 탄소섬유쉬트와 콘크리트의 접합면에서 발생되는 부착파괴의 메카니즘은 명확히 구명될 필요가 있다. 본 연구에서는 양생온도, 콘크리트의 표면상태 및 함수율 등의 환경요소변화에 따른 탄소섬유쉬트와 콘크리트의 인발접착강도을 파악함으로써 환경요소의 영향을 평가하였으며 아울러, 탄소섬유쉬트와 콘크리트와의 부착성능을 결정하는 유효부착길이 및 평균부착응력도를 평가하였다. 연구결과, 인발접착강도에 미치는 환경요소에서 양생온도가 가장 중요한 영향인자로 나타났으며, 인장전단부착 실험으로부터 얻어진 유효부착길이 및 평균부착응력도는 각각 15 cm 및 9.78~11.88kgf/$\textrm{cm}^2$ 내외라고 사료된다.

연약지반에 시공된 전주의 실물인장실험을 통한 수평변위분석 (Horizontal Displacement Analysis of Electric Pole from Full Scale Pull-Out Test in Softground)

  • 안태봉
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.115-126
    • /
    • 2009
  • 연약지반상에 시공하는 수많은 전주가 태풍 등의 외부하중으로 전도파괴가 발생한다. 본 연구에서는 근가위치, 근가깊이, 근가개수, 전주근입깊이 등을 달리하며 연약지반에 실물크기의 전주에 인장실험을 실시하여 전주의 수평 변위분석을 실시하였다. 전주는 10개의 유형으로 나누어 실험한 결과 변위는 근가의 위치 및 수량, 전주기초의 근입깊이에 따라 뚜렷한 차이를 나타냈다. 초기하중 재하시 상부에서 굴절된 양상을 보이다 점증하중에 따라 전주의 중앙부로 굴절의 양상이 전이되었다. 근가위치는 G.L(-) 0.5[m]인 상태에서 전주기초 깊이 1.3[m]를 추가로 근입시 최대 수평변위는 약 1.6배의 감소를 보여 전주의 안정성이 증가하였다. 근가의 수는 근가 2개를 설치하는 것이 변위에 유리하나 큰 차이는 아니며 근가를 다수 설치하고 굴착면적이 커져 시공성이 떨어지는 단점이 있으므로 근가를 1개만 설치하여도 좋은 것으로 판단된다.

이형 GFRP 보강근의 기본정착길이에 대한 연구 (A Study on the Basic Development Length of GFRP Rebar With Ribs)

  • 문도영
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.485-493
    • /
    • 2010
  • 국내에서 개발된 이형 GFRP 보강근은 표면에 구축된 이형의 전단강도가 콘크리트의 전단강도 보다 상대적으로 작아 이형철근과 달리 이형 자체가 전단파괴되는 파괴모드를 보이는 것으로 확인된바 있다. 본 논문에서는 이형을 갖는 GFRP 보강근의 기본정착길이를 인발실험과 설계모델식과 해석적 엄밀식을 통해 고찰하였다. 실험결과, 동일조건하에서 파괴모드가 변화되는 임계정착길이가 이형철근은 직경의 15배, 이형 GFRP 보강근은 20배인 것으로 나타났다. 또한 실험결과를 ACI440.1R-03 설계모델식에 적용하여 분석한 결과, 충분한 횡구속이 수반된 경우 직경 9 mm의 이형 GFRP 보강근의 기본정착길이는 직경의 21배인 것으로 나타났다. 반면, ACI440.1R-06에 제시된 기본정착길이 모델은 실험결과에 비하여 너무 과대한 기본정착길이를 요구하는 것으로 나타났다. Cosenza 등(2002)의 모델은 실험결과에 비하여 더 적은 기본 정착길이를 요구하므로, 설계목적의 사용은 제한적인 것으로 판단되었다.

Tractive performance evaluation of seafloor tracked trencher based on laboratory mechanical measurements

  • Wang, Meng;Wang, Xuyang;Sun, Yuanhong;Gu, Zhimin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권2호
    • /
    • pp.177-187
    • /
    • 2016
  • To evaluate the tractive performance of tracked trencher on seafloor surface, a new shear stress-displacement empirical model was proposed for saturated soft-plastic soil (SSP model). To validate the SSP model, a test platform, where track segment shear test can be performed in seafloor soil simulacrum (bentonite water mixture), was built. Series shear tests were carried out. Test results indicate that the SSP model can describe the mechanical behavior of track segment with good approximation in seafloor soil simulacrum. Through analyzing the main external forces applied to seafloor tracked trencher during the uniform linear trenching process, a drawbar pull prediction model was deduced with the SSP model. A tracked walking mechanism of the seafloor tracked trencher prototype was built, and verification tests were carried out. Test results indicate that this prediction model was feasible and effective; moreover, from another side, this conclusion also proved that the SSP model was effective.

Variation of Pull-out Resistance of Geogrid with Degree of Saturation of Soil

  • Yoo, Chungsik;ALI, TABISH
    • 한국지반신소재학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2020
  • This paper presents the results of experimental investigation on the effect of degree of saturation of soil on the pullout behavior of a geogrid. Different test variables were taken into account while performing the experiment including the soil physical conditions based on water content and external loading applied. The soil used was locally available weathered granite soil. The tests included variations in saturation of about 90%, 80%, 70% and 45% (optimum moisture content). The pullout tests were performed according to ASTM standard D 6706-01. The results indicate that increasing the degree of saturation in the soil decreases the pull-out capacity, which in turn decreases the interface friction angle and interaction coefficient. The decrease in the pullout interface coefficient was observed to be around 12.50% to 33.33% depending on the normal load and degree of saturation of the soil. The test results demonstrated the detrimental effect of increasing the degree of saturation within the reinforce soil on the pullout behavior of reinforcement, thus on the internal stability. The practical inferences of the outcomes are analyzed in detail.

거친표면 GFRP 보강근의 쪼갬부착파괴강도 및 거동 고찰 (Bond Splitting Strength and Behavior of GFRP Reinforcement with Roughened Surface)

  • 문도영
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.23-29
    • /
    • 2011
  • 본 연구는 거친 표면을 갖는 GFRP 보강근의 쪼갬에 의한 부착파괴 거동과 파괴강도를 인발실험을 통해 규명하였다. 실험변수로서, 보강근의 직경, 콘크리트 피복 및 콘크리트 압축강도에 대하여 실험을 수행하였으며, 동일한 변수에 대하여 5개의 실험 결과를 평균하여 실험에 대한 오차를 최소화 하였다. 또한 쪼갬에 의한 부착파괴거동을 인발력과 변위결과로부터 고찰하였다. 쪼갬부착파괴강도 결과는 여러 연구자가 제안한 이형철근 및 FRP 보강근의 쪼갬부착파괴강도 평가모델식과 비교하였다. 분석결과, 거친표면을 갖는 GFRP 보강근의 쪼갬부착파괴강도는 Harajli 등(1995)이 제안한 모델을 이용하여 가장 근사하게 평가할 수 있는 것으로 나타났다.

유리섬유 지오그리드의 마찰특성에 관한 실험연구 (A Experimental Study on the Friction Characteristics of the Fiber Glass Geogrid)

  • 채영수;박연준;유광호;송신석;강승문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.496-503
    • /
    • 2000
  • The friction between soils and the geosynthetics varies depending upon the types and characteristics of the involved materials. Many engineers have studied the frictional characteristics between the two materials in may way but the results obtained so far is not satisfactory. In this study the frictional characteristics between the soil and the geogrid were examined through laboratory direct shear test and pull-out test. Tests were conducted on two different types of geogrid: Polyester grids(PET) which are currently used and newly developed fiber-glass grids(FG). Result showed that FG grid yielded smaller displacements and uniform displacement distribution mainly due to much higher stiffness. Therefore, it is expected that more efficientbfl support and displacement control can be achieved by the FG grid.

  • PDF

펄스방전 확공형 앵커의 현장시험 (Pull-out Test of Pulse Powered Underreamed Anchors)

  • 김낙경;주용선;김성규;서효균;김태훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1014-1021
    • /
    • 2008
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The pulse powered anchor is an underreamed anchor by using high voltage electrokinetic pulse energy. In this paper, conceptual introduction of the pulse powered anchor was presented. Anchor pull-out tests were performed at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. Data were analyzed in order to verify the performance of pulse powered anchors.

  • PDF