Discrete element modelling of geogrids with square and triangular apertures

  • Chen, Cheng;McDowell, Glenn;Rui, Rui
    • Geomechanics and Engineering
    • /
    • 제16권5호
    • /
    • pp.495-501
    • /
    • 2018
  • Geogrid application that has proved to be an effective and economic method of reinforcing particles, is widely used in geotechnical engineering. The discrete element method (DEM) has been used to investigate the micro mechanics of the geogrid deformation and also the interlocking mechanism that cannot be easily studies in laboratory tests. Two types of realistically shaped geogrid models with square and triangle apertures were developed using parallel bonds in PFC3D. The calibration test simulations have demonstrated that the precisely shaped triangular geogrid model is also able to reproduce the deformation and strength characteristics of geogrids. Moreover, the square and triangular geogrid models were also used in DEM pull-out test simulations with idealized shape particle models for validation. The simulation results have been shown to provide good predictions of pullout force as a function of displacement especially for the initial 30 mm displacement. For the granular material of size 40 mm, both the experimental and DEM results demonstrate that the triangular geogrid of size 75 mm outperforms the square geogrid of size 65 mm. Besides, the simulations have given valuable insight into the interaction between particle and geogrid and also revealed similar deformation behavior of geogrids during pullout. Therefore, the DEM provides a tool which enable to model other possible prototype geogrid and investigate their performance before manufacture.

Signal-based AE characterization of concrete with cement-based piezoelectric composite sensors

  • Lu, Youyuan;Li, Zongjin;Qin, Lei
    • Computers and Concrete
    • /
    • 제8권5호
    • /
    • pp.563-581
    • /
    • 2011
  • The signal-based acoustic emission (AE) characterization of concrete fracture process utilizing home-programmed AE monitoring system was performed for three kinds of static loading tests (Cubic-splitting, Direct-shear and Pull-out). Each test was carried out to induce a distinct fracture mode of concrete. Apart from monitoring and recording the corresponding fracture process of concrete, various methods were utilized to distinguish the characteristics of detected AE waveform to interpret the information of fracture behavior of AE sources (i.e. micro-cracks of concrete). Further, more signal-based characters of AE in different stages were analyzed and compared in this study. This research focused on the relationship between AE signal characteristics and fracture processes of concrete. Thereafter, the mode of concrete fracture could be represented in terms of AE signal characteristics. By using cement-based piezoelectric composite sensors, the AE signals could be detected and collected with better sensitivity and minimized waveform distortion, which made the characterization of AE during concrete fracture process feasible. The continuous wavelet analysis technique was employed to analyze the wave-front of AE and figure out the frequency region of the P-wave & S-wave. Defined RA (rising amplitude), AF (average frequency) and P-wave & S-wave importance index were also introduced to study the characters of AE from concrete fracture. It was found that the characters of AE signals detected during monitoring could be used as an indication of the cracking behavior of concrete.

직접전단을 받는 보강점토의 거동에 관한 연구 (A Study on the Behavior of Reinforced Clay Subjected to Direct Shear)

  • 유한규
    • 한국지반공학회지:지반
    • /
    • 제10권4호
    • /
    • pp.67-82
    • /
    • 1994
  • 본 연구에서는 강 함유재에 의한 점토에서의 전단강도 증가를 예측하기 위하여 직접전단하에서 힘의 한계평형에 근거한 보강점토 모델이 제안되었다. 본 모델은 함유재의 방향과 길이, 함유재와 점토사이 부착응력 및 함유재의 이동에 따른 흙의 수동저항력이 보강점토의 거동에 미치는 영향을 고려하였다. 이론적인 예측과 비교검토하기 위하여 개폐된 전단박스로 구성된 직접전단 장치를 이용하여 직접전단시험을 실시하였다. 또한 함유재와 점토사이의 부착응력을 산정하기 위하여 인발실험을 실시하였다. 시험결과 보강점토의 전단응력의 증가 또는 감소는 함유재의 방향과 점토의 함수비와 관련되어 있음을 알았다. 이론적인 예측과 시험결과를 비교한 결과 본 이론적인 모델은 함유재의 방향과 함유재의 이동에 따른 흙의 수동 저항력이 보강점토의 역학적인 거동에 미치는 영향을 비교적 잘 예측 해주고 있음을 알 수 있었다.

  • PDF

구속효과를 고려한 토목섬유의 인발저항력 평가기법 (Assessment Method of Geosynthetic Pullout Resistance Considering Soil Confinement Effect)

  • 방윤경;이준대;전영근
    • 한국지반공학회논문집
    • /
    • 제17권6호
    • /
    • pp.135-148
    • /
    • 2001
  • 본 연구에서는, 인장력과 이에 수직방향으로 작용하는 압축음력을 동시에 고려한 직교이방성 합성부재의 인장력-변형률 관계식(Bhagwan, Agarwal & Brouoan, 1990)을 응용하여, 토목섬유인발저항력 및 인장력에 미치는 구속응력의 영향을 정량적으로 평가할 수 있는 기법을 제시하였다. 이를 위해서, 국내에서 판매되고 있는 부직포, 직포, 복합포 및 지오그리드 등의 토목섬유를 대상으로 구속신장시험(Confined Extension Test) 및 실내인발시험(Laboratory Pull-out Test)을 수행하였다. 시험결과를 토대로하여 구속응력이 토목섬유의 인장력-변형률 거동에 미치는 영향을 분석하였고, 구속응력에 의한 토목섬유 인장력 및 인발저항력의 변화를 정량적으로 평가하였다. 분석결과, 구속응력의 크기가 증가할수록 토목섬유의 할선계수가 뚜렷이 증가하였으며, 본 연구 제안방법에 의한 토목섬유-흙 사이의 마찰저항각 $\delta\; 및\; 보정계수\; a^2$값이 기존의 인발저항력 평가방법에 비하여 다소 큰 값을 나타내어, 인발저항력 산정시 토목섬유에 가해지는 구속음력의 크기를 고려하는 본 연구 제시방법의 경우에 보다 큰 인발저항력이 얻어짐을 알 수 있었다.

  • PDF

Racking shear resistance of steel frames with corner connected precast concrete infill panels

  • Hoenderkamp, J.C.D.;Snijder, H.H.;Hofmeyer, H.
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1403-1419
    • /
    • 2015
  • When precast concrete infill panels are connected to steel frames at discrete locations, interaction at the structural interface is neither complete nor absent. The contribution of precast concrete infill panels to the lateral stiffness and strength of steel frames can be significant depending on the quality, quantity and location of the discrete interface connections. This paper presents preliminary experimental and finite element results of an investigation into the composite behaviour of a square steel frame with a precast concrete infill panel subject to lateral loading. The panel is connected at the corners to the ends of the top and bottom beams. The Frame-to-Panel-Connection, FPC4 between steel beam and concrete panel consists of two parts. A T-section with five achor bars welded to the top of the flange is cast in at the panel corner at a forty five degree angle. The triangularly shaped web of the T-section is reinforced against local buckling with a stiffener plate. The second part consists of a triangular gusset plate which is welded to the beam flange. Two bolts acting in shear connect the gusset plate to the web of the T-section. This way the connection can act in tension or compression. Experimental pull-out tests on individual connections allowed their load deflection characteristics to be established. A full scale experiment was performed on a one-storey one-bay 3 by 3 m infilled frame structure which was horizontally loaded at the top. With the characteristics of the frame-to-panel connections obtained from the experiments on individual connections, finite element analyses were performed on the infilled frame structures taking geometric and material non-linear behaviour of the structural components into account. The finite element model yields reasonably accurate results. This allows the model to be used for further parametric studies.

An Experimental Study on the Biomechanical Effectiveness of Bone Cement-Augmented Pedicle Screw Fixation with Various Types of Fenestrations

  • Yoon, Sang Hoon;Lee, Sang Hyung;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.779-789
    • /
    • 2022
  • Objective : To analyze the effects of the number and shape of fenestrations on the mechanical strength of pedicle screws and the effects of bone cement augmentation (BCA) on the pull-out strength (POS) of screws used in conventional BCA. Methods : For the control group, a conventional screw was defined as C1, a screw with cannulated end-holes was defined as C2, a C2 screw with six pinholes was defined as C3, and the control group type was set. Among the experimental screws, T1 was designed using symmetrically placed thru-hole type fenestrations with an elliptical shape, while T2 was designed with half-moon (HM)-shaped asymmetrical fenestrations. T3 and T4 were designed with single HM-shaped fenestrations covering three pitches and five pitches, respectively. T5 and T6 were designed with 0.6-mm and 1-mm wider fenestrations than T3. BCA was performed by injecting 3 mL of commercial bone cement in the screw, and mechanical strength and POS tests were performed according to ASTM F1717 and ASTM F543 standards. Synthetic bone (model #1522-505) made of polyurethane foam was used as a model of osteoporotic bone, and radiographic examinations were performed using computed tomography and fluoroscopy. Results : In the fatigue test, at 75% ultimate load, fractures occurred 7781 and 9189 times; at 50%, they occurred 36122 and 82067 times; and at 25%, no fractures occurred. The mean ultimate load for each screw type was 219.1±52.39 N for T1, 234.74±15.9 N for T2, 220.70±59.23 N for T3, 216.45±32.4 N for T4, 181.55±54.78 N for T5, and 216.47±29.25 N for T6. In comparison with C1, T1, T2, T3, T4, and T6 showed significantly different ultimate load values (p<0.05). However, when the values for C2 and the fenestrated screws were evaluated with an unpaired t test, the ultimate load value of C2 significantly differed only from that of T2 (p=0.025). The ultimate load value of C3 differed significantly from those of T1 and T2 (C3 vs. T1 : p=0.048; C3 vs. T2 : p<0.001). Linear correlation analysis revealed a significant correlation between the fenestration area and the volume of bone cement (Pearson's correlation coefficient r=0.288, p=0.036). The bone cement volume and ultimate load significantly correlated with each other in linear correlation analysis (r=0.403, p=0.003). Conclusion : Fenestration yielded a superior ultimate load in comparison with standard BCA using a conventional screw. In T2 screws with asymmetrical two-way fenestrations showed the maximal increase in ultimate load. The fenestrated screws can be expected to show a stable position for the formation of the cement mass.

초고강도 콘크리트를 활용한 고온가열 이후의 탄소 보강근과 철근의 잔류 부착성능 평가 (Evaluation of Residual Bond Stress between Carbon-fiber Reinforced Polymer and Steel Rebar Using Ultra-High-Performance-Concrete after Elevated Temperature)

  • 유선재;이호진;원천봉;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.169-176
    • /
    • 2021
  • 본 연구에서는 고온가열 이후의 탄소 보강근의 잔류 부착 강도 평가를 위하여 상온, 150℃에 따른 부착실험을 수행하였으며, 탄소 보강근과의 비교를 위한 D10 및 D13 철근도 고온 가열한 이후 잔류 부착 강도를 평가하였다. 실험 결과, 150℃ 가열 이후 탄소 보강근의 부착 강도는 상온 대비 약 9.94% 감소하였다. 반면 가열 이후 D10 철근 및 D13 철근 모두 탄소 보강근 대비 부착 강도 감소율이 적게 나타났다. 또한 온도 가열 이후 최대부착 강도에서 발생한 슬립도 탄소 보강근과 철근 모두 줄어드는 경향을 보였다. 이를 통해 고온가열에 따른 부착 강도와 슬립 감소의 상관관계를 확인하였으며, 부착-슬립 곡선을 나타내었다. 최종적으로는 실험 결괏값을 상대부착 강도로 나타냄으로써 가열 이후 탄소 보강근 및 철근의 잔류 부착성능을 확인하고자 하였다.

비파괴 시험기법을 이용한 록볼트의 건전도 평가(I) -수치해석 및 실험적 적용성 평가- (Estimation of Rockbolt Integrity by Using Non-Destructive Testing Techniques(I) -Numerical and Experimental of Applicability-)

  • 이종섭;이용준;엄태원;한신인;이인모
    • 한국터널지하공간학회 논문집
    • /
    • 제8권1호
    • /
    • pp.3-12
    • /
    • 2006
  • 본 연구의 목적은 록볼트의 건전도를 평가하기 위하여 록볼트의 비파피시험을 기술하고 바파괴시험의 적용성을 조사하는 것이다. 록볼트 자체와 그라우팅제를 포함한 록볼트의 건전도를 평가하기 위하여, 수치해석 및 실험적 방법을 이용한 두가지 방법이 적용되었다. 수치해석 방법에서는 분석은 DISPERSE 프로그램을 이용하여 록볼트의 분산선도를 해석하였다. 분산선도 곡선은 지중근입되어 있는 록볼트에 대한 그라우팅제의 두께와 강성에 대한 영향을 보여준다. 이로 부터 록볼트의 건전도 시험을 위한 최적의 주파수를 추정할 수 있으며, 그 결과 L(1, 0) 모드에서 20~120kHz가 최적의 주파수로 산정되었다. 실험적 방법에서는 실험실에서 사료를 제작하여 파괴 및 비파괴시험을 실시하였다. 비파괴 실험에서는 타격을 이용한 저주파수 모드와 초음파 트랜스듀서를 이용한 고주파수 모드를 통하여 록볼트의 상태를 조사할 수 있다. 실험실에서 수행된 비파괴실험으로부터, 유도파는 주변의 그라우팅제의 강도가 증가하거나 (또는 증가하고) 결함부 영역이 증가할 때 감쇠가 커짐을 알 수 있었다. 그리고 인발시험으로부터 록볼트의 극한지지력을 추정하였다. 본 연구는 록볼트의 건전도 평가에 비파괴시험이 매우 유용한 방법임을 보여준다.

  • PDF

초속경 시멘트를 사용한 가압식 쏘일네일링의 주입시간에 따른 마찰저항특성에 관한 연구 (A Study on the Frictional Resistance Chracteristics of Pressurized Soil Nailing Using Rapid Setting Cement)

  • 이아름;신은철;이철희;임용관
    • 한국지반신소재학회논문집
    • /
    • 제17권4호
    • /
    • pp.1-10
    • /
    • 2018
  • 쏘일네일링 공법은 일반적으로 중력식 그라우팅 방법으로 사용되고 있으나, 그라우팅으로 인한 공동발생 및 충진 불량 문제를 해결하고자 최근에는 가압식 쏘일네일링 공법의 개발과 적용사례가 증가하고 있다. 가압식 그라우팅은 일반적으로 포틀랜트 시멘트와 물을 혼합하여 사용하나 소요강도 발현까지 10일 이상 걸리기 때문에 초속경 시멘트를 혼합하여 사용하고 있다. 이에 이 논문에서는 가압식 그라우팅 주입시간을 고려하여 적정 겔타임이 확보되는 초속경 시멘트 혼합비 30%가 가압식 쏘일네일링을 하기에 적합하다고 판단하였다. 화강풍화토 지반을 대상으로 모형토조를 제작하여 네일체의 인발실험을 한 결과, 주입시간 10초에서는 변형률 15% 일 때의 인발력이 5.7kN으로 중력식과 비교하였을 때 약 1.5배의 보강효과가 나타났다. 압력시간을 10초, 20초, 30초, 40초의 조건으로 달리할 경우에는 주입시간 증가에 따른 마찰저항력이 선형적으로 증가하나, 한계주입압력을 넘는 수준의 주입시간에서는 수압파쇄 효과로 인해 마찰저항력이 감소하는 것을 확인하였다. 또한, 수치해석을 통하여 무보강 사면과 중력식, 가압식 쏘일네일링으로 보강된 사면의 안정을 비교분석 하였다.

철근격자망을 사용한 슬래브-벽체 접합부의 구조성능 (Structural Performance of RC Slab-Wall Joints Reinforced by Welded Deformed Steel Bar Mats)

  • 박성식;윤영호;이범식
    • 토지주택연구
    • /
    • 제2권1호
    • /
    • pp.61-68
    • /
    • 2011
  • 본 연구는 벽식구조 아파트의 슬래브와 벽체를 철근격자망으로 배근할 경우 접합부의 구조성능을 검증하기 위해 수행되었다. 이를 위해 벽체와 연결된 불연속단의 캔틸레버형 슬래브 시험체를 사용하여 철근격자망 상부근의 정착길이와, 철근격자망의 정착부에 일반 구부림 철근을 사용하여 정착한 경우의 정착방법 및 길이를 변수로 실험을 수행하였다. 결과는 다음과 같다. (1) 슬래브-벽체 외부접합부의 철근망 시공에서 슬래브 철근망은 벽체의 철근 선까지 배근하고 이음길이를 확보한 별도의 철근을 $90^{\circ}$ 표준갈고리로 정착하는 경우, 정착길이와 단면적이 확보되면 강도 발현에 문제가 없는 것으로 나타났다. (2) 슬래브 철근망을 접합부에서 이음할 때 철근망의 철근을 벽체 속으로 매입하면 강도는 더욱 증가한다. 그러나 최고강도에 도달한 이후의 연성은 이음이 없는 것과 동일한 것으로 나타났다. (3) 슬래브-벽체 외부접합부에서 단부 모멘트에 대한 슬래브 하부 압축콘크리트의 파괴시 변형률은 일반 콘크리트 보와 비교할 때 훨씬 큰 것으로 나타났다. 이는 슬래브-벽체 접합부가 $90^{\circ}$를 이루고 있어 이에 따른 구속효과가 있기 때문인 것으로 판단된다.