• Title/Summary/Keyword: Pull-out 강도

Search Result 197, Processing Time 0.027 seconds

Pull-out Strength Characteristics of Revegetation Species Root used for Forest Road Slope (임도사면 녹화식물뿌리의 인발강도특성에 관한 연구)

  • Ji, Byoung Yun;Jung, Do Hyun;Chun, Kwon Suk;Kim, Jong Yoon
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.1
    • /
    • pp.45-49
    • /
    • 2006
  • The objective of this study is to offer a basic information to select the plant species for environmentally friendly forest road by quantifying the pull-out strength by 18 species used for a revegetation of forest road slope. In the investigation of the root depth growth during 17 months, Indigobush amorpha showed maximum depth of 34.0 cm and perennial ryegrass showed minimum depth of 17.7 cm among all species. The pull-out strength by herb species was $0.054ton/m^2/plant$ for exotic species, $0.085ton/m^2/plant$ for indigenous species, and by shrub species was $0.049ton/m^2/plant$. There were no large difference among herb species in pull-out strength, but shrub species were approximately 9 times stronger than herb species. Thus, for maximizing tightening effect and use of inner soil space. The mixed seeding using herb for erosion control and shrub for shallow failure protection would make up optimal revegetation of forest road slope.

Experimental Study on Bond Strength of Deformed Bars in Artificial Lightweight Aggregate Concrete (경량콘크리트의 부착특성에 대한 실험적 연구)

  • Cho, Jang-Se;La, Sung-Jun;Kim, Min-Sook;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.43-53
    • /
    • 2011
  • For reinforced concrete members, the bond strength is one of the important factors between two materials: concrete and reinforcing element. This study concerns the bond strength of deformed bars in artificial lightweight aggregate concrete by pull-out test. 144 cubic specimens were manufactured for the test. concrete compressive strength, size of deformed bar and embedment lengths were considered as variables in this study. Normal concrete with W/C ratio 50% specimens were tested for the comparison. Test results included the bond stress-slip responses and modes of failure. Bond strength increased with an increase of compressive strength of concrete according to W/C ratio. The equation of bond stress of polymer-modified lightweight aggregate concrete were proposed by regression analysis based on the result.

A Study on the Basic Development Length of GFRP Rebar With Ribs (이형 GFRP 보강근의 기본정착길이에 대한 연구)

  • Moon, Do Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5A
    • /
    • pp.485-493
    • /
    • 2010
  • GFRP rebar with ribs resemble those of deformed steel rebar was developed in 2005. It was reported that ribs of the GFRP rebar were sheared off due to the lower shear strength of polymer. In this study, the basic development length of the GFRP rebar was investigated through pull-out tests, models specified in ACI440.1R-03 and -06, and empirical model derived by Cosenza et al. (2002). As a results of pull-out tests, the critical embeddment length, which is defined as the length when failure mode is changed from pull-out to bar fracture, was 20 times of bar diameter for GFRP rebar and was 15 times for steel rebar. It is believed that the basic development of the GFRP rebar is 21 times of bar diameter, which is determined from the application of average bond strength into the model equation specified in ACI440.1R-03. Compared to the model equation in ACI440.1R-06, that in ACI440.1R-03 is recommendable for design purpose. The Cosenza et al.'s model underestimates the basic development length of the GFRP rebar.

Effect of Pull-out Property by Shape and Mechanical Property of Reinforcing Fiber on the Flexural Behavior of Concrete (보강섬유의 형상과 물성에 따른 인발특성이 콘크리트의 휨거동에 미치는 영향)

  • Kim, Hong-Seop;Nam, Jeong-Soo;Kim, Jung-Hyun;Han, Sang-Hyu;Kim, Gyu-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.41-50
    • /
    • 2014
  • This study evaluated the bonding property of fiber and flexural behavior of fiber reinforced concrete. Amorphous steel fiber, hooked steel fiber and polyamide fiber was used for evaluation of bonding property and flexural behavior. As a result, the hooked steel fiber was pulled out from matrix when peak stress. However amorphous steel fiber occurred shear failure because bonding strength between fiber and matrix was higher than tensile strength of fiber. Polyamide fibers occurred significantly displacement to peak stress because of elongation of fiber. After that peak stress, fiber was cut off. Amorphous steel fiber reinforced concrete had a greater maximum flexural load compared with hooked steel fiber reinforced concrete because bonding performance between fiber and matrix was high and mixed population of fiber was many. However flexural stress was rapidly reduced in load-deflection curve because of shear failure of fiber. Flexural stress of hooked steel fiber reinforced concrete was slowly reduced because fiber was pulled out from the matrix. In the case of polyamide fiber reinforced concrete, flexural stress was rapidly lowered because of elongation of fiber. However flexural stress was increased again because of bonding property between polyamide fiber and matrix. The pull-out properties of the fiber and matrix has effect on the deformation capacity and flexural strength of fiber reinforced concrete.

Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案))

  • Kim, Seong-Hwan;Kim, Dong-Ho;Kim, Hyun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

A Study on the Improvement of Interfacial Bonding Shear Strength of Ti50-Ni50 Shape Memory Alloy Composite (Ti_{50}-Ni_{50} 형상기억합금 복합체의 계면 접학 전단강도 향상에 관한 연구)

  • Lee, Hyo-Jae;Hwang, Jae-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2461-2468
    • /
    • 2000
  • In this paper, single fiber pull-out test is used to measure the interfacial bonding shear strength of $Ti_{50}-Ni_{50}$ shape memory alloy composite with temperature. Fiber and matrix of $Ti_{50}-Ni_{50}$ shape memory alloy composite are respectively $Ti_{50}-Ni_{50}$ shape memory alloy and epoxy resin. To strengthen the interfacial bonding shear stress, various surface treatments are used. They are the hand-sanded surface treatment, the acid etched surface treatment and the silane coupled surface treatment etc.. The interfacial bonding shear strength of surface treated shape memory alloy fiber is greater than that of surface untreated shape memory alloy fiber by from 10% to 16%. It is assured that the hand-sanded surface treatment and the acid etched surface treatment are the best way to strengthen the interfacial bonding shear strength of $Ti_{50}-Ni_{50}$ shape memory composite. The best treatment condition of surface is 10% HNO$_3$ solution in the etching method to strengthen the interfacial bonding shear strength of $Ti_{50}-Ni_{50}$ shape memory alloy composite.

Strain Rate Effect on tensile properties of Hooked Steel Fiber and PVA Fiber hybrid reinforced cementitious composites (후크형 강섬유와 PVA섬유를 하이브리드 보강한 시멘트복합체의 인장특성에 미치는 변형속도의 영향)

  • Son, Min-Jae;Kim, Gyu-Yong;Lee, Sang-Kyu;Kim, Gyeong-Tae;Baek, Jae-Uk;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.208-209
    • /
    • 2018
  • In this study, the tensile properties of hybrid fiber reinforced cementitious composites under the high strain rate was evaluated. Experimental results, the HSF1.5PVA0.5 shown the highest tensile strength because the PVA fiber suppressed the micro cracks in the matrix around the hooked steel fiber and improved the pull-out resistance of hooked steel fiber. Thus, DIF of strain capacity and fracture toughness of HSF1.5PVA were greatly improved. Also, the fracture toughness was greatly improved because the tensile stress was slowly decreased after the peak stress by improvement of the pull-out resistance performance of hooked steel fiber at strain rate 101/s.

  • PDF

Bond Behavior of Concrete According to Replacement Ratio of Fly Ash and Compressive Strength of Concrete (플라이애시 치환율 및 압축강도에 따른 콘크리트의 부착 거동)

  • Lee, Hyung-Jib;Suh, Jeong-In;Yoo, Sung-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2016
  • Several researches on high volume fly ash concrete have been conducted to investigate its fundamental material properties such as slump, strength and durability and however, research on the structural behavior of bond strength is essential for the application of this high volume fly ash concrete to structural members because of the necessity of reinforcement. But the exact design code for application and researches on the bond behavior of high volume fly ash concrete lack yet. To achieve such a goal, this paper evaluates experimentally the bond behavior of high volume fly ash concretes by direct pull-out test and compares between the current test results and existing research results. By the test results, it is shown that the bond behavior of high volume fly ash concrete is similar to that of general concrete. And by the comparison between test and existing research, it is shown that bond stress of high volume fly ash concrete is underestimated, as the embedment length gets longer.

Bonding Strength of bonded Polymer Concrete on Cured Cement Concrete (경화된 콘크리트에 접착된 폴리머 콘크리트의 부착강도 특성)

  • 홍승호;권순민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.353-358
    • /
    • 2001
  • The cement concrete pavements are designed twenty years of performance life in Korea. At the present time, some expressways have been elapsed seventy percent of performance life which are detecting local failures. The most repair methods using to repair failures are partial depth repair and full section repair. These methods are most important bonding strength between rapid curing materials and substrate concrete pavements. This study was performed to evaluate bonding strength of the composites section made of rapid curing material and substrate concrete pavements. The pull-out tester was used to test bonding strength for the composites section made of each materials. In the results of the test, the bonding strength values of the epoxy mortar and acrylic mortar are higher than those of the other materials. The performance life of repaired section is affected by various factor. The bonding strength of bonded composites section may be affect the performance life, significantly.

  • PDF