• 제목/요약/키워드: Pull test

검색결과 584건 처리시간 0.024초

현장 Single Well Push-Pull 실험을 통한 탈질산화반응 각 단계의 반응속도 측정

  • Yeong, Kim;Jin Hun, Kim;Bong Ho, Son;Seong Uk, Eo
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.77-82
    • /
    • 2004
  • Quantifying rates of microbial processes under subsurface conditions is difficult, and is most commonly approximated by laboratory studies using aquifer materials. In this study a single-well, 'push-pull' test method is adapted for the in situ determination of denitrification rates in groundwater aquifers. The rates of stepwise reduction of nitrate to nitrite, nitrous oxide, and molecular nitrogen were determined by performing a series of push-pull tests at an experimental well field of Korea University. A single Transport Test, one Biostimulation Test, and four Activity Tests were conducted for this study. Transport tests are conducted to evaluate the mobility of solutes used in subsequent tests. These included bromide (a conservative tracer), fumarate (a carbon and/or source), and nitrate (an electron acceptor). At this site, extraction phase breakthrough curves for all solutes were similar, indicating apparent conservative transport of the solutes prior to biostimulation. Biostimulation tests were conducted to stimulate the activity of indigenous heterotrophic denitrifyinc microorganisms. Biostimulation was detected by the simultaneous production of carbon dioxide and nitrite after each injection. Activity tests were conducted to quantify rates of nitrate, nitrite, and nitrous oxide reduction. Estimated zero-order degradation rates decreased in the order nitrate '||'&'||'gt; nitrite '||'&'||'gt; nitrous oxide. The series of push-pull tests developed and field tested in this study should prove useful for conducting rapid, low-cost feasibi1ity assessments for in situ denitrification in nitrate-contaminated aquifers.

  • PDF

Cool Roof 성능을 확보한 Honey Comb Panel 지붕 접합부의 인발 성능 평가 (Evaluation of Pull-Out Strength of Connections with Roof Cladding using Honey Comb Panel Secured Cool Roof Performance)

  • 이인호;박상우;고광일;정미자;이은택
    • 한국강구조학회 논문집
    • /
    • 제28권3호
    • /
    • pp.139-149
    • /
    • 2016
  • 건물의 지붕 외장재는 강한 풍압 또는 태풍으로 인한 부압으로 지붕 외장재와 지붕 골조 간에 접합철물인 스크류가 인발되어 지붕외장재의 박리, 비산을 초래함으로써 인명, 재산적 피해가 발생함으로서 스크류 인발에 대한 대책이 요구되고 있다. 본 연구에서는 '인서트 너트'라는 철물을 지붕외장재가 설치되는 프레임에 체결하여 스크류의 관통 깊이를 증가시켜 인발 저항력을 높였으며 시험편 인장실험을 통한 단순 스크류 접합과 인서트 너트 접합의 인발 강도를 비교하였고 Solid Work를 이용한 모델링 해석을 통해 실제 사용되는 지붕외장재와 동일한 조건의 실험체를 제작하여 정적실험 및 가상의 풍하중을 이용한 동적실험을 통해 일반적인 스크류 접합 지붕외장재와 인서트 너트를 사용한 지붕외장재를 비교하였다.

최대 견인 출력시 트랙터 엔진의 견인 부하 분석 (Analysis of Drawbar Load Acting on Tractor Engine at Maximum Drawbar Power)

  • 김수철;김경욱;김대철
    • Journal of Biosystems Engineering
    • /
    • 제34권2호
    • /
    • pp.71-76
    • /
    • 2009
  • This study was conducted to investigate the load acting on a tractor engine when it delivers the maximum power at drawbar. The results of the drawbar tests on the 5 locally-made and 14 imported tractors conducted at NIAE in 2004, and the 15 tractors tested at OECD test stations in foreign countries were analyzed and presented by the torque load ratio, defined as a ratio of the engine torque load caused by drawbar pull to its full-load capacity, as a function of pull speed. The NIAE test results showed that the torque load ratio increased from 20 to 80% with pull speed less than 5 km/h. At speeds faster than 5 km/h, it was 80${\sim}$110% regardless of the pull speed. However, the OECD test results showed that the torque load ratio was evaluated mostly to be 70${\sim}$90% in the entire pull speed range. The same trend was also shown for the maximum drawbar load. The difference in the torque load ratio may be attributable to bias-ply tires for locally-made and some imported tractors. It is also suggested that the input torque load may be increased safely up to 120% of the full load capacity of the tractor engine for an accelerated life test of tractor transmissions.

현장계측에 의한 접이식 웨지 장착 강관네일의 인발거동 평가 (Estimation of Pull-out Behavior for Steel Pile Nailing installed Foldable Wedge by Field Measurement)

  • 권교근;최봉혁;김경민
    • 한국지반신소재학회논문집
    • /
    • 제8권4호
    • /
    • pp.19-25
    • /
    • 2009
  • 본 연구에서는 접이식 웨지가 장착된 경량 강관네일의 인발저항 증진효과를 평가하기 위하여 동일 지반조건에서 시험시공을 통한 접이식 웨지가 장착된 네일과 웨지가 장착되지 않은 네일의 현장 인발거동 특성을 평가하였다. 강관네일의 현장 인발거동 특성 평가는 극한인발저항력 ($T_L$), 단위주면 마찰저항($q_s$, $u_{max}$), 인발강성계수($K_{\beta}$) 및 네일의 인장력 분석을 통하여 수행되었으며, 그 결과 접이식 웨지를 장착할 경우 풍화토 지반에서 약 30% 정도의 인발저항 증진효과가 있는 것으로 나타났다.

  • PDF

상대변위측정기를 이용한 지반앵커의 보유인장력 측정 (Measurement of Retaining Tensile Load with the Relative Displacement Detector of Ground Anchors)

  • 정현식;한광석;이영생
    • 한국지반공학회논문집
    • /
    • 제33권10호
    • /
    • pp.59-69
    • /
    • 2017
  • 지반내 근입된 앵커의 인장력은 시간이 경과하면서 점차 변화하게 되는데 이때 초기 인장력의 변화는 보통 정착헤드의 정착조건과 인장자재의 기계적 특성에 의해 1차적으로 감소하게 되며, 이후 추가적인 인장력의 변화는 대부분 정착장의 정착조건과 주변 지반특성에 기인한 시간의존적인 정착거동에 좌우된다. 따라서 본 논문에서는 이러한 인장력 변화를 비교적 쉽게 측정 및 분석할 수 있는 상대변위측정기를 이용한 측정시스템에 대해서 연구하였다. 검토결과 실규모 모형시험을 통해서 본 측정시스템의 적용성을 확인 하였으며, 또한 풍화암에 정착된 지반앵커를 대상으로 실시한 현장 시험결과와도 유사함을 확인함에 따라 본 측정시스템의 적용성을 확인하였다. 그리고 초기인장력이 비교적 크게 감소된 시험앵커를 대상으로 추가적인 인발시험을 실시하였으며 이를 통해 인장형 앵커의 인발거동을 확인하였다.

아크 용접 와이어의 장거리 송급을 위한 Push-pull 방식의 와이어 송급장치 개발 (Development of Push-pull Type Arc Welding Wire Feeder)

  • 윤현준;황인성;김동철;강문진;최기갑
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.39-43
    • /
    • 2013
  • It is difficult to feed welding wire stably, when the distance between welding wire feeder and welding torch is far enough. In order to solve this problem, arranging a extension wire feeder between them could be one of useful methods. However, the welding wire could be twisted up in the extension cable between extension and terminal wire feeders in the case that RPM of extension wire feeding motor is higher than that of terminal motor. In this study, feeding problem of normal push-pull wire feeding system occurred at low welding current range less than 250A. In order to solve the problem, two new wire feeding systems of push-pull type were introduced. Welding wire feeding tests were preformed in the range of 150A to 400A with the developed push-pull feeding system. In addition, weldability test was performed at the welding current of 200A, 300A, and 400A. The welding wire twisting problem that was observed in the normal feeding system did not occur in the new push-pull wire feeding system.

Protrusion Jaw가 적용된 볼 당김시험을 이용한 솔더 접합부의 강도와 파괴 메커니즘 분석에 관한 연구 (Evaluation of Pull Strengths and Fracture Modes of Solder Joino by Modified Ball Pull Testing with Protrusion Jaw)

  • 김형일;한성원;김종민;최명기;신영의
    • Journal of Welding and Joining
    • /
    • 제23권4호
    • /
    • pp.34-40
    • /
    • 2005
  • There have been numerous approaches to examine the bonding strengths of solder joints. However, despite the technical and practical limitations, the precedent test methods such as the ball shear and ball pull tests are being used in industrial applications. In this study, the optimum jaw pressure with the modified protrusion jaw was introduced in order to obtain higher successful rate f3r ball pull testing. Furthermore, the pull strengths and fracture modes of Sn-8Zn-3Bi, Sn-4Ag-0.7Cu, and Sn-37Pb eutectic solder after isothermal aging tests ($100^{\circ}C,\;150^{\circ}C$), were evaluated with the protrusion jaw. The pull strength-displacement hysteresis curves and fracture surfaces were carefully investigated to evaluate the correlation between the pull strengths and the fracture modes of each solder. In conclusion, it is verified that Au-Zn IMCs (Intermetallic Compounds) have a detrimental effect on the pull strengths and changed fracture modes of Sn-8Zn-3Bi solder. Meanwhile, the microstructure transformation influences the degradation of pull strengths of Sn-4Ag-0.7Cu and Sn-37Pb solders.

Verification of CFD analysis methods for predicting the drag force and thrust power of an underwater disk robot

  • Joung, Tae-Hwan;Choi, Hyeung-Sik;Jung, Sang-Ki;Sammut, Karl;He, Fangpo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.269-281
    • /
    • 2014
  • This paper examines the suitability of using the Computational Fluid Dynamics (CFD) tools, ANSYS-CFX, as an initial analysis tool for predicting the drag and propulsion performance (thrust and torque) of a concept underwater vehicle design. In order to select an appropriate thruster that will achieve the required speed of the Underwater Disk Robot (UDR), the ANSYS-CFX tools were used to predict the drag force of the UDR. Vertical Planar Motion Mechanism (VPMM) test simulations (i.e. pure heaving and pure pitching motion) by CFD motion analysis were carried out with the CFD software. The CFD results reveal the distribution of hydrodynamic values (velocity, pressure, etc.) of the UDR for these motion studies. Finally, CFD bollard pull test simulations were performed and compared with the experimental bollard pull test results conducted in a model basin. The experimental results confirm the suitability of using the ANSYS-CFX tools for predicting the behavior of concept vehicles early on in their design process.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

근위골절술을 위한 Staple 설계 (A Newly Designed Miniplate Staple for High Tibial Osteotomy)

  • 문무성;배대경
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF