• Title/Summary/Keyword: Public Water

Search Result 1,682, Processing Time 0.036 seconds

Waterborne Pathogens Identification in Public Bathroom by PCR-Reverse Blot Hybridization Assay

  • Choi, Seung-Gu;Song, Woon-Heung;Lee, Jae-Sang;Yang, Byoung-Seon;Choi, Myeong-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.3
    • /
    • pp.120-123
    • /
    • 2011
  • A total of 30 water samples were collected from 30 different public baths in Seoul, Korea. Contamination of public bath water by waterborne pathogens can cause disease outbreaks and contribute to increase background rates of disease. Pathogens in water was filtered by nitrocellulose membrane with $0.45{\mu}m$ pore size. The membrane filters were analyzed by both cultivation and polymerase chain reaction (PCR) amplification of partial 16S rRNA gene. Various microorganisms including 4 Escherichia coli/Shigella spp. 1 Salmonella spp. 3 Pseudomonas aeruginosa and 2 Mycobacterium spp. were identified by reverse blot hybridization assay (REBA). PCR-REBA was able to identify many bacterial genera in one assay. Our results suggest that appropriate hygiene practice and continuous monitoring is needed for reducing health risk associated with public bath houses.

  • PDF

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

Critical Success Factors on PPP Water Project in a Developing Country: Evidence from Indonesia

  • SURACHMAN, Eko Nur;HANDAYANI, Dian;SUHENDRA, Maman;PRABOWO, Sakti
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.1071-1080
    • /
    • 2020
  • This study aims to explore the critical success factors of the Water Public-Private Partnership (PPP) Projects in developing country with evidence from Indonesia. We all know that water is a basic need and therefore it becomes very important for the governments especially in the developing countries to develop and formulate a comprehensive water policy to deliver and manage the water services in the most appropriate manner as well tackle several challenges such as budget and project efficiency. In this context, PPP is a promising scheme to address the water problems, hence it becomes important to reveal the success factors of water PPP projects. An Analytic Hierarchy Process (AHP) questionnaire built from delphi methods is used to capture the perception of the relevant stakeholders in relation to the success factors. The results of this study show the most critical success factors in PPP water projects is the support and acceptance of the stakeholders from the community, whereas the private and public entities are the the second and third important factors. These findings contribute to the success of the PPP stakeholders by enhancing the policy-making decision process and by executing the water policies to support the development of PPP in the Water Sector.

The Efficacy of Water Purification and Distribution of Ammonia Oxidizing Bacteria in Shihwa Constructed Wetland (시화호 인공습지의 수질정화 및 암모니아 산화균의 분포 연구)

  • Kim, Seiyoon;Kim, Misoon;Lee, Sunghee;Lim, Miyoung;Lee, Youngmin;Kim, Zhiyeol;Ko, GwangPyo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • Water quality and the distribution of ammonia oxidizing bacteria were characterized in constructed wetland of Shihwa lake. Both physico-chemical parameters and fecal indicator microorganisms including total coliforms, E.coli, Enterococcus spp. were measured. In addition, denaturant gradient gel electrophoresis (DGGE) was carried out after PCR amplification of amoA gene from input, output, and wetland sites of the Banwol, Donghwa, and Samhwa stream in Shihwa lake area. Physico-chemical parameters were in proper range for typical nitrifying bacteria to grow and perform their biological activities. Average concentrations of fecal indicator microorganisms of wetland samples were lower than those of input sites. These results suggested that microbial water quality improved by the process of constructed wetland. According to phylogenetic information obtained from DGGE from study sites, distribution of nitrifying bacteria from each of input, output, and wetland were generally distinctive one another. In addition, distribution of nitrifying bacteria between Banwol and Donghwa streams showed higher similarity (52.6%) than this of Samhwa stream (15.2%). These results indicated that characteristics of ammonia oxidizing bacteria in Samhwa were unique in comparison with those of Banwol and Donghwa stream.

Assessment of Disinfection By-Products in Drinking Water in Korea (음용수 중 소독부산물 발생현황에 관한 연구)

  • Shin, Dong-Chun;Chung, Yong;Choi, Yoon-Ho;kim, Jun-Sung;Park, Yeon-Sin;Kum, Hee-Jung;Jeon, Hee-Kyoung
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • The main purpose of applying the chlorination process during water treatment is for disinfection. Research results, however, indicate that disinfection by-products including trihalomethanes, haloacetic acids, haloacetonitriles, haloketones, and chloropicrin can be produced by chlorination process. Some of these disinfection by-products are known to be potential human carcinogens. This three-year project is designed to establish a standard analysis procedure for disinfection by-products in drinking water and investigate the distribution and sources of specific disinfection by-products. The occurrence level of DBPs in drinking water was below 50$\mu\textrm{g}$/L in most cases. THMs in plant effluent accounted for 48% of all DBPs measured, whereas HAAs accounted for 24%, HANs 14%, haloketones 5%, chloral hydrate 7%, and chloropicrin 2%. Chloroform was found to be the major THMs compound (71%), followed by bromodichloromethane (21%), dibro-mochloromethane (7%), and bromoform (3%), The concentration of DBPs formed in distribution systems increased from those detected in plant effluent. Results would play an important role in exposure assessment as a part of the risk assessment process, and would give basic information for establishment of disinfection by-products reduction and management procedures.

  • PDF

A Study on pollution of spring in Incheon Area (인천 지역 약수터의 오염에 대한 연구)

  • Kim, Kyung-Ae;Lee, Byeng-Ok;Kim, Ou-Mok;Hur, Myung-Je;Kim, Kyung-Tae;Ro, Jae-Il;Choe, Choon-Suck;Go, Jong-Myoung;Kim, Yong-Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.35-50
    • /
    • 2007
  • In order to investigate water pollution of spring, we carried out the experiments on mineral water, rainwater and surrounding soil of several springs collected in Incheon area from February to August in 2007. The results were as follows. 1. Soil : This study investigated the pH and organic matter contents in the soil which effect on microorganisms. The pH value was from 4.5 to 5.3 on average and organic matter contents ranged from 1.09% to 5.6% and E. coli, K. pneumoniae, S. faecalis and other microorganisms were isolated. 2. Natural mineral water : As the rainfall increased, the concentration of $No_3-N$, consumption of $KMnO_4$ and the number of microorganisms was increased while the other physicochemical items were not affected. The microorganism isolated in the natural mineral water were as follows: E. coli, K. oxytoca S. faecalis, S. facium, and so on from evacuation; E. agglomerans, E. amnigenus, E. cloacae, E. sakazakii and so on from the environments and evacuation. Detection of these microorganisms shows that the environment around the spring had been exposed to excrements of the warm blood animal. 3. Rain : The coliforms in the rain were the identical one detected from the mineral water and the soil. In conclusion the quality of natural mineral water is influenced by rain, resident bacteria of soil and surrounding environment. This study will be the basic data of characteristics of spring in Incheon area and also this result will give useful aids for the efficient control of spring.

Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities (공공하수처리시설의 총인기준 강화에 따른 비용효과분석)

  • Jeong, Won-Gu;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

A Comparison of Environmental Risk Perceptions between General Public and Experts (일반인과 전문가의 환경문제에 대한 위해도 인식 차이)

  • 장은아;박종연;임영욱;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.2
    • /
    • pp.75-84
    • /
    • 2001
  • Differences in risk perception on major environmental issues between general public and environmental experts were investigated in this study. Questionnaire surveys were conducted to samples from general public and environmental experts during March and April, 2000. Total number of responses was 1,126 including 773 persons from general public and 353 experts. Risk perceptions on 26 environmental issues were related with the need to regulate each issue, controllability, experience, political views, interest in environmental problem, satisfaction of environment, severity of environmental pollution. There was statistically significant difference in risk perceptions between general public and experts. Overall, general public was likely to perceive risks associated with environmental problem, as well as social need to regulate these problems more than experts. The issues with high risk perception and need to regulate were 'automobile exhaust', 'industrial air pollution', ocean pollution by industrial waste and oil exhaust', 'air pollution by chemicals', 'surface water pollution by waste from household', 'industrial and hospital waste', 'surface water pollution by pesticide'and'sewage and food waste'. Consequently, it seems necessary to manage these issues, prior to others.

  • PDF

Distribution of Antibiotic Resistant Escherichia coli and Water Quality in Waterscape Facilities (물놀이형 수경시설의 수질과 항생제 내성 대장균 분포에 관한 연구)

  • Yoon, Sang-Hoon;Kim, Seon-Gyeong;Kim, Nan-Hee;Wi, Whan;Lee, Se-Hang;Jo, Gwang-Woon;Kim, Dong-Su;Cho, Young-Gwan
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.3
    • /
    • pp.225-233
    • /
    • 2014
  • Objective: This study was performed in order to investigate the distribution of antibiotic resistant E. coli and water quality in waterscape facilities. Methods: Nine waterscape facilities were selected and classified into three types: ground, wall and general fountain. The items analyzed in this study were pH, turbidity, $KMnO_4$ consumption, total colony, total coliforms, fecal coliforms and E. coli. Additionally, an antibiotic resistance test on E. coli was performed. Results: There were no sampling sites that exceeded the permitted limits of water quality, but the concentration of pollutants was high at the beginning operation in June. Moreover, concentration of turbidity, $KMnO_4$ consumption and total colony were higher in ground fountains than in wall and general fountains. Five species of antibiotic resistant E. coli were detected from three sampling sites. Conclusions: The waterscape facilities were significantly contaminated with water microorganisms, especially total colony, total coliforms and fecal coliforms. Disinfection and filtration systems to remove pollutants should be installed for safe waterscape facilities.

Application of Membrane Technology in Japan

  • Minami, Katsuyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.58-73
    • /
    • 1995
  • Membrane filtration is a promising technology for efficient solid/liquid separation in water purification. In FY 1991, the Ministry of Health and Welfare, Japanese Government launched a comprehensive research project "MAC 21" for development of membrane technology and its application to public water supply. The project was conducted by the Water Purification Process Association (WPPA), under the supervision of the Institute of Public Health. By the research project from FY 1991 to FY 1993, we confirmed that microfiltration (MF)/ultrafiltration (UF) technology was applicable to water purification and MF/UF was a effective method for the removal of such contaminants as particulate matter and coliforms. The Guideline Committee organized under the Technical Committee prepared a the guidelines on application of membrane system to small-scale public water supplies, based on the results as written above. The guidelines has been published in Dec., 1994 by WPPA.4 by WPPA.

  • PDF