• Title/Summary/Keyword: Pt complex

Search Result 124, Processing Time 0.02 seconds

Acute Normovolemic Hemodilution Effects on Perioperative Coagulation in Elderly Patients Undergoing Hepatic Carcinectomy

  • Guo, Jian-Rong;Jin, Xiao-Ju;Yu, Jun;Xu, Feng;Zhang, Yi-Wei;Shen, Hua-Chun;Shao, Yi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4529-4532
    • /
    • 2013
  • Background: Acute normovolemic hemodilution (ANH) has been widely used to prevent the massive blood loss during hepatic carcinoma. The influences of ANH on coagulation function are still controversy, especially in elderly patients. The study observed ANH effects on coagulation function and fibrinolysis in elderly patients undergoing the disease. Materials and Methods: Thirty elderly patients (aged 60-70 yr) with liver cancer (ASA I or II) taken hepatic carcinectomy from February 2007 to February 2008 were randomly divided into ANH group (n=15) and control group (n=15). After tracheal intubation, patients in ANH group and control group were infused with 6% hydroxyethyl starch (130/0.4) and Ringer's solution, respectively. Blood samples were drawn from patients in both groups at five different time points: before anesthesia induction (T1), 30 min after ANH (T2), 1 h after start of operation (T3), immediately after operation (T4), and 24 h after operation (T5). Then coagulation function, soluble fibrin monomer complex (SFMC), prothrombin fragment (F1+2), and platelet membrane glycoprotein (CD62P and activated GP IIb/GP IIIa) were measured. Results: The perioperative blood loss and allogeneic blood transfusion were recorded during the surgery. The perioperative blood loss was not significantly different between two groups (p>0.05), but the volume of allogeneic blood transfusion in ANH group was significantly less than in control group ($350.0{\pm}70.7$) mL vs. ($457.0{\pm}181.3$) mL (p<0.01). Compared with the data of T1, the prothrombin time (PT) and activated partial thromboplastin time (APTT) measured after T3 were significantly longer (p<0.05) in both groups, but within normal range. There were no significant changes of thrombin time (TT) and D-dimer between two groups at different time points (p>0.05). SFMC and F1+2 increased in both groups, but were not statistically significant. PAC-1-positive cells and CD62P expressions in patients of ANH group were significantly lower than those at T1 (p<0.05) and T2-T5 (p>0.05). Conclusions: ANH has no obvious impact on fibrinolysis and coagulation function in elderly patients undergoing resection of liver cancer. The study suggested that ANH is safe to use in elderly patients and it could reduce allogeneic blood transfusion.

Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

Regional Citrate Anticoagulatinln for Continuous Renal Replacement Therapy in Children (소아의 지속적 신대체요법에서 Citrate 항응고요법의 경험)

  • Hahn Hye-Won;Park Young-Seo
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.76-82
    • /
    • 2005
  • Purpose : Regional anticoagulation with trisodium citrate for continuous renal replacement therapy(CRRT) is an effective and safe method, with lower bleeding risk. However it is not widely used because of complex current protocols used to prevent anticipated metabolic derangements. We evaluated simplified regional anticoagulation protocols with ACD-A(R) solution and commercially available calcium-containing dialysis solution. Methods : The medical records of twenty-eight patients who underwent CRRT were reviewed. Hemofilter life span according to the anticoagulation method used was compared, and laboratory findings at Pre- and 48 hours post-CRRT initiation were compared in the citrate-based CRRT group. Results : Of the twenty-eight Patients, five patients underwent citrate-based CRRT Hemofilter life span was 1.60 $\pm$ 0.72 days, showing no significant differences with the hemofilter life span in the heparin based and LMWH based CRRT group. No patients experienced hemorrhagic complications. PT, aPTT, sodium, t$CO_{2}$, iCa levels showed no difference in pre- and post-CRRT. Total calcium levels were increased. At the recommended postfilter iCa level, j.e., 0.25-0.39 mmol/L, all five patients needed increased amount of citrate infusion, and Ca infusion requirement was decreased. Conclusion : Simplified regional citrate anticoagulation with calcium-containing dialysate is an effective and safe method, and is not associated with increased hemofilter clotting. However, increased postfilter iCa level is recommended.

  • PDF

Evaluation of confidence for measurement of VOCs in indoor air (실내공기질 VOCs 측정의 신뢰도 평가를 위한 연구)

  • Kim, Myoung Ock;Kim, Young Lan;Hong, Suk Young;Heo, Gwi Suk;Lim, Hyun Woo;Choe, Seoung Hun;Lee, Won Suk;Han, Jin Seok;Kim, Kum Hee
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • To establishment of PT Program for Indoor air quality field that manufacture of confidential development PTMs (proficiency testing materials) and examined of proficiency testing evaluation included sampling process whether or not that is valid. Confirmation of homogeneity and stability of PTMs prepared. PTMs were confirmed to be homogeneous enough to be used as proficiency testing materials since withinbottle homogeneities of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The result of this study showed that the Robust RSD of proficiency testing for VOCs (volatile organic compounds) appeared 23~43% in concentration of 50~320 ${\mu}g/m^3$ for Method A(Distribution by adsorption in Tenax-tube of VOCs), but less 13~42% in concentration of 200~1200 ${\mu}g/m^3$, 16~31% in concentration of 100~450 ${\mu}g/m^3$ for Method B (distribution by VOCs of gas phase in 10L Tedalr bag), C (directly sampling of cylinder with high pressure) respectively. The result of this study showed that method C with sampling is most adequate to the proficiency testing for VOCs in indoor air.