• Title/Summary/Keyword: Psychrometric Chart

Search Result 11, Processing Time 0.029 seconds

Drawing of Twenty Kinds of State and Process on Psychrometric Chart (습공기선도 상에 20 종류의 상태 및 과정 값의 작도)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process (실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구)

  • Lee Hung Joo;Kim Yong Ku
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF

A Study on Pattern Recognition to Compute Guidelines Based on Evidence for Ecological Healing Environment at Agha Khan Hospital in Karachi - Focused on Human Thermal Comfort Model (HTCM), for Karachi, using Climate Consultant Program

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.27-35
    • /
    • 2015
  • Purpose: Healthcare is on the whole a personal and critical service that consumer's use, whereas hospitalization is as a rule painful, because nature nurtures and Sun Light Luminosity for healthcare settings is considered healing. The performance and design of climate responsive buildings such as AKU requires a detailed study of attributes of climate both at micro as well as macro level. The therapeutic value of contact with nature through window view, greenery and landscape is calculated there. Method: A two prong strategy is been devised for this article, at micro level three typical morphologies are analysed by creating same environment of neighboring building on sun shading chart, radiation and temperature range. Since the analysis of local climate helps to determine the design strategies for hospital Healing Environment which is suitable for Karachi climate; in order to track the macro climatic behaviour, a considerable analysis of psychometrics chart for AKU Karachi are designed on Climate Consultant (CC) and analysed by Machine Learning. Climate Consultant proposes different design strategies suitable for Karachi. And on the other hand time wise illumination sources for clinical area which are then measured on psychrometric chart- according to singular space: multi patient admission, secondly: acute ambulatory ward, and tertiary: multi windowed space according to the mushrabiyah and sky light pattern. Result: Our findings support the hypothesis that windowed wall is 75-80% more healing wall; an accelerated evidence was found for healing at macro level if the form of the hospital is designed according to the climatologically preferences, whereas at micro level: the light resource becomes the staff attentiveness determinant. In Conclusion evidence was provided that the actual form of luminosity results consequently in satisfaction while light entering from several set of windows and other sources might be valued if design according to the healing environment. The data added on the sun shading chart to calculate rays entraining into space in patient room equal to 124416.21 Watts/ meter $m^2$ is calculated as precise healing rate-and is confirmed by questionnaire from patients belonging from each clinical stage having different illnesses.

The Study about Variation of Physiology Signal based on EEG due to Variation of Illumination (조도 변화에 따른 뇌파 기반 생체신호 변화에 관한 연구)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.55-58
    • /
    • 2012
  • By using EEG and HRV, subjects were estimated on their psychological and physiological reaction when reading psychrometric chart in 7 point century font, in an environmental test room in the condition of temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/sec], giving variation in illuminance to 0.1, 300, 600, 1000, 1300 and 1600[lux]. As a result, it was at 1300[lux] that absolute ${\alpha}$ wave, SMR, SDNN were most vitalized, and also both sides ${\alpha}$ wave asymmetry index, SEF50, HRT, stress and fatigue degree were at the lowest. It was found that a certain illuminance which minimizes psychological stress and fatigue degree while enhancing concentration and task achievement stably does exist.

Theoretical Determination of Optimum Rotating Speed of Desiccant Rotor (이론적 방법에 의한 제습로터 최적 회전속도의 결정)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.603-608
    • /
    • 2008
  • A simple equation to find a optimum speed of desiccant rotor is presented in this theoretical study. Usually the determination of optimum speed of desiccant rotor requires tedious and lengthy procedures by solving governing differential equations with many complicated parameters. The determining equation of optimal rotating speed is derivated from governing differential equations with three linearization assumptions, which simplify temperature profile linear along the desiccant rotor depth, psychrometric chart within a proper range, and relative humidity-sorption capacity relation. This study shows that the dominant parameters of optimal rotating speed of desiccant rotor are NTU, flow velocity, desiccant rotor depth, and temperature different between dehumidification and regeneration. The comparison shows the good agreement between complicated calculation results and simple theoretical equation prediction.

  • PDF

Derivation and Analysis of Dimensionless Parameters Dominating the Dehumidification Characteristics of a Desiccant Rotor (제습로터의 운전특성을 재배하는 무차원 인자의 도출과 해석)

  • Lee Gilbong;Kim Min Soo;Lee Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.611-619
    • /
    • 2005
  • In a previous work of the authors, the heat and mass transfer in a desiccant rotor was analyzed theoretically through linearization assumptions and four dimensionless parameter groups dominating the dehumidification process were arranged. In this work is verified whether the four dimensionless parameters also play the dominant roles in more realistic situations where the nonlinear factors affect the heat and mass transfer. The results show that the dehumidification characteristics are closely similar to each other as long as the four dimensionless parameters have the same set of values while the rotor configurations and/or the operation conditions are different from each other. The four dimensionless parameters are $\Psi,\;\chi,\;\sigma$ and N, where $\Psi$ implies the average gradient of relative humidity lines in the psychrometric chart, $\chi$ the heat capacity of the rotor and $\sigma$ the sorption capacity of the rotor, and N implies the number of transfer unit.

A Physioclimatic Study on the Thermal Sensation in Korea (한국의 열감분포에 관한 생리 기후학적 연구 - 신유효온도를 중심으로 -)

  • 강철성
    • Journal of the Korean Geographical Society
    • /
    • v.32 no.2
    • /
    • pp.129-140
    • /
    • 1997
  • The purpose of this paper is to analyze thermal sensation which is measured bv human physioclimatic reactions in Korea. Human physiological reactions to temperature and relative humidity are analyzed to produce a nomogram from which average human reactions to the climatic factors can be deduced. Thermal - indices for each regular stations in both South (1961-1990) and North Korea(1973-1994) are calculated based on monthly meteorological data. A generalized annual physioclimatic maps for each Annual Cumulative Thermal Index for the 52 stations are constructed to show how men tend to feel in various areas. Resuts of this study can be applied for evaluation of thermal environment in our daily activities, and for searching relevant sports training-sites.

  • PDF

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan (기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구)

  • Kim, Yeong Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.191-200
    • /
    • 2016
  • The ventilation effect of a ventilation system, which is classified as the forced ventilation and natural ventilation, is predominantly dependent on the combination of air supply and discharge. Perhaps the simplest ventilation is merely supplying the air as it is. However, to improve the indoor working environment during the summer, an air supply that is cooled to some extent has been widely adopted. Recently, a cooling method utilizing the vaporization of water was introduced. In this study, the performance of an evaporation-type air supply unit that was produced by Japan K-company and was installed in a shoe-manufacturing plant in Busan was investigated. The purpose of the experiment was to measure how much the supplied air could be cooled. From this experimental study, we confirmed that the evaporation-type air supply system is efficient, capable of improving the working environment during the summer while minimizing the energy cost.