• Title/Summary/Keyword: Psychoacoustic Parameters

Search Result 34, Processing Time 0.027 seconds

Audio Transcoding for Audio Streams from a T-DTV Broadcasting Station to a T-DMB Receiver

  • Bang, Kyoung-Ho;Park, Young-Cheol;Seo, Jeong-Il
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.664-667
    • /
    • 2006
  • We propose an efficient audio transcoding algorithm that can convert audio streams from terrestrial digital television broadcasting service stations to those for terrestrial digital multimedia broadcasting hand-held receivers. The proposed algorithm avoids the complicated psychoacoustic analysis by calculating the scalefactors of the bit-sliced arithmetic coding encoder directly from the signal-to-noise ratio parameters of the AC-3 decoder. The bit-allocation process is also simplified by cascading the nested distortion control loop. Through subjective evaluation, it is shown that the proposed algorithm provides comparable audio quality to tandem coding but it requires much smaller complexity.

  • PDF

A Study on the Relationship between Sound Quality and Structural Mechanics in Automobiles (차량 구조 강성과 소음 음질간의 상관도 연구)

  • Choi Jongdae;Kim Sangmin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.239-242
    • /
    • 2000
  • In the present study, the influence of car body structures to the noise and vibration characteristics has been sought. The numerical modal analysis for the body-in-white is employed to predict the vibratory response of structure, and then followed by the experimental modal testing to confirm the validity of the model. Using the results of numerical simulations with the designated modal parameters, the optimal structural configuration has been deduced. Special interests have been paid to the sensitivity of sound quality to the structural integrity. Since the structural integrity has a close relationship to the structure-born noise, the substantially low frequency range, which is far below the frequency range almost barely sensible by human auditory organ but still quite influential to overall impression, is especially examined. The subjective assessment agrees with the objective evaluation by means of traditional sound measures as well as psychoacoustic metrics.

  • PDF

The Correlation between Human sensibility and psychoacoustic parameters for natural sound and artificial noise (자연음과 소음에 대한 감성과 심리음향인자와의 상관성)

  • Kim, Wuon-Shik;Jho, Moon-Jae;Hwang, Jae-Ho;Lee, Ji-Hye;Suh, Jae-Gap
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.489-494
    • /
    • 2000
  • 제품과 사용자간에 필연적으로 존재하는 소리를 쾌적하게 하기 위한 연구로서 자연음 6종과 소음 6종의 음압(dB)이 비슷하도록 조절하였을 때 소리의 어떠한 물리적 특성이 긍/부정감성에 주된 영향을 미치는지를 파악하기 위하여 남/녀 각각 35명씩의 대학생들에게 7점척도의 8가지 형용사 쌍을 이용한 음질평가 청감실험을 한 결과 물소리를 포함한 자연음은 소음보다 대체로 긍정감성이 높게 평가되었고 긍정감성과 심리음향인자와의 상관성은 Loudness의 -0.37을 비롯하여 "-"상관성을, Unbiased annoyance와 심리음향인자들과의 상관성은 Loudness의 0.92를 비롯한 "+" 상관성을 각각 갖었으며 여자는 남자보다 긍/부정감성에 더욱 예민하게 반응하는 것으로 나타났다.

  • PDF

Comparison of the Surgical Results in Mutational Dysphonia between Unilateral Shortening of Thyroid Cartilage Method and Bilateral Shortening of Thyroid Cartilage Method in Type III Thyroplasty (변성발성장애의 제3형 갑상연골성형술시 갑상연골익의 편측절제술과 양측절제술과의 치료성적 비교)

  • 최홍식;김세헌;김영호;이익호;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.7 no.1
    • /
    • pp.61-68
    • /
    • 1996
  • Failure to change from the higher pitched voice of preadolescence to the lower pitched voice of adolescence and adulthood is called "mutational dysphonia" The voice is weak, thin, breathy, hoarse, and mono-pitched. If the voice theraphy was failed, surgery to lower vocal pitch which is refered to thyroplasty type III, is indicated. We compared the post-op acoustic parameters with pre-op data in unilateral antero-posterior shortening of the thyroid cartilage method and bilateral antero-posterior shortening of the thyroid cartilage method each other. Bilateral antero-posterior shortening of the thyroid cartilage method shows significant drop of fundamental frequency and speaking fundamental frequency statistically than unilateral shortening method. There was no significant differences in Jitter, Shimmer, SNR, MFR and other psychoacoustic analysiss parameters between two groups. These data shows that unequal tension of the vocal cord in uilateral antero-posterior shortening of the thyroid cartilage method does not control the pitch effectively so bilatreal shortening method in Type III thyroplasty is recommandable procedure in surgery of the mutational dysphonia.

  • PDF

STUDY ON THE OPTIMAL DESIGN OF A VEHICLE INTAKE SYSTEM USING THE BOOMING NOISE AND THE SOUND QUALITY EVALUATION INDEX

  • LEE J. K.;PARK Y. W.;CHAI J. B.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, an index for the evaluation of a vehicle intake booming noise and intake sound quality were developed through a correlation analysis and a multiple factor regression analysis of objective measurement and subjective evaluation data. At first, an intake orifice noise was measured at the wide-open throttle test condition. And then, an acoustic transfer function between intake orifice noise and interior noise at the steady state condition was estimated. Simultaneously, subjective evaluation was carried out with a 10-scale score by 8 intake noise and vibration expert evaluators. Next, the correlation analysis between the psychoacoustic parameters derived from the measured data and the subjective evaluation was performed. The most critical factor was determined and the corresponding index for intake booming noise and sound quality are obtained from the multiple factor regression method. And, the optimal design of intake system was studied using the booming noise and the sound quality evaluation index for expectation performance of intake system. Conclusively, the optimal designing parameters of intake system from noise level and sound quality whose point of view were extracted by adapting comparative weighting between the booming noise and sound quality evaluation index, which optimized the process. These work could be represented guideline to system engineers, designers and test engineers about optimization procedure of system performance by considering both of noise level and sound quality.

Psychological and Physiological Responses to the Rustling Sounds of Korean Traditional Silk Fabrics

  • Cho, Soo-Min;Yi, Eun-Jou;Cho, Gil-Soo
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.450-456
    • /
    • 2006
  • The objectives of this study were to investigate physiological and psychological responses to the rustling sound of Korean traditional silk fabrics and to figure out objective measurements such as sound parameters and mechanical properties determining the human responses. Five different traditional silk fabrics were selected by cluster analysis and their sound characteristics were observed in terms of FFT spectra and some calculated sound parameters including level pressure of total sound (LPT), Zwicker's psychoacoustic parameters - loudness(Z), sharpness(Z), roughness(Z), and fluctuation strength(Z), and sound color factors such as ${\Delta}L\;and\;{\Delta}f$. As physiological signals, the ratio of low frequency to high frequency (LF/HF) from the power spectrum of heart rate variability, pulse volume (PV), heart rate (HR), and skin conductance level (SCL) evoked by the fabric sounds were measured from thirty participants. Also, seven aspects of psychological state including softness, loudness, sharpness, roughness, clearness, highness, and pleasantness were evaluated when each sound was presented. The traditional silk fabric sounds were likely to be felt as soft and pleasant rather than clear and high, which seemed to evoke less change of both LF/HF and SCL indicating a negative sensation than other fabrics previously reported. As fluctuation strength(Z) were higher and bending rigidity (B) values lower, the fabrics tended to be perceived as sounding softer, which resulted in increase of PV changes. The higher LPT was concerned with higher rating for subjective loudness so that HR was more increased. Also, compression linearity (LC) affected subjective pleasantness positively, which caused less changes of HR. Therefore, we concluded that such objective measurements as LPT, fluctuation strength(Z), bending rigidity (B), and compression linearity (LC) were significant factors affecting physiological and psychological responses to the sounds of Korean traditional silk fabrics.

A Study of the Sound Quality Characteristics for Environmental Noise Assessments Parameters (음질을 고려한 환경소음 평가 인자의 기여도분석에 관한 연구)

  • Jo Kyoung-Sook;Cho Yeon;Hwang Dae-Sun;Hur Deog-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.129-136
    • /
    • 2006
  • For the environmental noise assessments. A weighted equivalent noise level (LeqA) is used to measure the time varying environmental noise. However, it is not appropriately reflect various environmental noise features and human emotions. The human perception of the noise is affected largely by the psychoacoustic characteristics of noise as well as the sound pressure level In this study, the effective factors of noise qualify are analyzed using the subjective assessment and statistical analysis of environmental noise, such as road traffic noise. construction site noise, noise in daily living. and other. The analysis methodology is composed to three steps as follows : firstly, the values of the sound qualify metrics of various noise sources were analyzed. And to classify the noise sources, we conducted a cluster analysis using sound quality metrics. Secondly, subjective jury testing was carried out using the methods of paired comparisons and semantic differential. Finally, the correlation between the subjective parameters and the noise quality metrics were analyzed. As a result. the human perception characteristics of the various environmental noise are described in some physical parameters of the noise qualify metrics.

Study on the Evaluation of Sound Quality of a Vehicle Interior Noise (차량의 실내소음에 대한 음질평가 연구)

  • Lee, J.K.;Chai, J.B.;Jang, H.K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.945-953
    • /
    • 2005
  • The purpose of this paper is to develop a linear regression model for the sound quality index of vehicle Interior noise. For this, objective measurement data of the vehicles driving in acceleration was measured. On the basis of analysis, psychoacoustic parameters were extracted and subjective evaluation was performed by noise and vibration expert evaluators. For the subjective evaluation, the paired comparisons and the semantic differential methods were used to evaluate sound quality of vehicle interior noise. By the paired comparison which evaluate two pairs of vehicle interior noise, the preference was estimated. With the semantic differential and the factor analysis, it was evaluated words of two pairs which expressed appropriately the sense of evaluator about noise source. Therefore the characteristics of the sound qualify for the vehicle were differentiated. From the results of both the correlation analysis and the multiple factor regression analysis, the sound quality evaluation model for the sense of human hearing was derived and indexed.

The Word Recognition Score According to Release Time on Automatic Gain Control (자동이득 조절에서 해제시간에 따른 어음인지점수 변화)

  • Hwang, S.M.;Jeon, Y.Y.;Park, H.J.;Song, Y.R.;Lee, S.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.385-394
    • /
    • 2010
  • Automatic gain control(AGC) is used in hearing aids to compensate for the hearing level as to reduced dynamic range. AGC is consisted of the main 4 factors which are compression threshold, compression ratio, attack time, and release time. This study especially focus on each individual need for optimum release time parameters that can be changed within 7 certain range such as 12, 64, 128, 512, 2094, and 4096ms. To estimate the effect of various release time in AGC, twelve normal hearing and twelve hearing impaired listeners are participated. The stimuli are used by one syllable and sentence which have the same acoustic energy respectively. Then, each of score of the word recognition score is checked in quiet and noise conditions. As a result, it is verified that most people have the different best recognition score on specific release time. Also, if hearing aids is set by the optimum release time in each person, it is helpful in speech recognition and discrimination.

Effects of Abdominal Respiration and Self Voice Feedback Therapy on the Voice Improvement of Patients with Vocal Nodules (복식호흡 훈련과 Self Voice Feedback 프로그램이 성대결절 환자의 음성개선에 미치는 효과)

  • Kwon, Soon-Bok;Wang, Soo-Geun;Yang, Byung-Gon;Jeon, Gye-Rok
    • Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.133-149
    • /
    • 2006
  • This study attempted to compare acoustic parameters, physiological observation and perceptual evaluation values obtained from the treatment and control groups in order to find out which of the self voice feedback therapies was better and which methods to train them were more effective. The experimental group carried out various self voice feedback therapies while the control group did only vocal hygiene. The acoustic measurement and voice manipulation for providing the patients visual, auditory feedback were done by a speech analysis software, Praat. The authors designed vocal hygiene, abdominal respiration and Praat self voice feedback therapies and applied them to 15 patients while applying only one vocal hygiene to 15 of the control group. For the purpose of examining the degree of their voice improvement after the treatment, pre- mid- and final evaluations were made for the two groups at the beginning, the 6th week and immediately after the 8th treatment session. Results of this study were as follows: The treatment group showed much improvement after receiving the voice treatment. In particular, acoustical and physiological indices from the optical endoscopy, pitch variation(Jitter), amplitude variation (Shimmer), maximum phonation time(MPT), and psychoacoustic evaluation showed statistically significant improvements over the control groups.

  • PDF