• Title/Summary/Keyword: Psycho-acoustic Evaluation

Search Result 29, Processing Time 0.03 seconds

A Psychological-acoustic Study on the Evalution Factors of Construction Noise Quality (건설소음의 음질평가요인에 관한 음향심리 연구)

  • Cho, Won-Hee;Yang, Man-Woo;Kwak, Kwang-Soo;Kim, Jae-Soo;Han, Myoung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.966-971
    • /
    • 2000
  • For the accurate evaluations of influence of construction noise, it is necessary to investigate not only physical characteristics of construction noise but also the subjective psycho-acoustical respects of individual persons. To develope the effective evaluation procedures for construction noise, we investigated Korean vocabularies which can express the feelings for construction noise, and analyzed psychological factors influencing on the subjective feelings of persons, through a series of psycho-acoustical experiments to construction noise. As a result of, it was found that the construction noise sources including the six factors. And this study intends to get the basic data for the evaluations about construction noise.

  • PDF

Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment (청감실험을 이용한 건축설비소음의 등급화)

  • You, Hee-Jong;Jung, Chul-Woon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF

Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise (공기조화 취출구 소음 평가를 위한 물리지수 분석)

  • Park, Hyeon-Ku;Kim, Hang;Go, Seong-Seok;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

An Experimental Study on the Selection of the Proper Vocabularies for Evaluation about the Noise Emission from Water Supply and Drain Installations in Apartment Bathroom (공동주택 욕실 급배수 설비소음 평가를 위한 적정어휘 선정에 관한 실험적 연구)

  • Song, Guk-Gon;Kim, Hang;Lee, Tai-Kang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.679-682
    • /
    • 2007
  • This study aims to select the proper vocabularies for evaluation about the noise emission from water supply and drain installations in apartment bathroom. As a result of surveying overlapping vocabularies and scores of them for each sound sources, 'annoying', 'noisy', 'dynamic' and 'strident' are main unpleasant vocabularies to the noise from water supply and drain installations in apartment bathroom. And vocabularies such as 'dynamic', 'sudden', 'loudness', 'noisy' are classified into the first factor by analysis.

  • PDF

Classification of Vocabulary for Evaluation on Machine Noise at High Noisy Workshop (고소음 작업장 기계소음 평가를 위한 어휘의 유형화)

  • Yun, Jae-Hyun;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.748-755
    • /
    • 2011
  • After the Industrialization of 1960s, while it has greatly contributed to the industrial development owing to acceleration of mechanization, but it is real situation that the countermeasure to noise damage generating at the loud noise workshop is scarcely made. Especially, the machine noise made at factory and workplace is so shocking and repeatedly reiterating terrible noise that most of the spot workers are forcedly imposing such dangers as the severe unpleasant feeling and hearing impairments. On such point of view, this research has attempted to extract the proper rating vocabulary in order for evaluation on machine noise made at the high noisy workshop, therefore it is considering that those extracted vocabularies could be utilized as the useful psycho-acoustic experiment for evaluation on machine noise, also for establishment of regulation standard in domestic high noisy workshop.

Evaluation on Reduction Effect about Noise of Hydraulic Turbine Dynamo in Dam using Auralization (가청화를 이용한 댐 수차 발전기소음의 저감효과 평가)

  • Soul, Soo-Hwan;Ju, Duck-Hoon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.400-408
    • /
    • 2008
  • Multipurpose Dam, it produces electric energy by converting the potential energy into kinetic energy utilizing its head and quantity of the water. However, in this process, since during the time when the turbine connected to the hydraulic turbine generator revolves, there occurs a ceaseless loud noise, and due to this condition, it is true state that those people who work at inside of the power plant are damaging as hard as they are unable to concentrate on their work. Not only this, because the hydro-electric power generator room that locates at middle section between the hydraulic turbine room and the office is very large space volume, also since it was constructed chiefly by the reflecting material, it is functioning of amplify the noise when operating the generator, the soundproof measure against this condition is necessitated. On such viewpoint, I have presented the problem point of the relevant Hydraulic turbine dynamo and Hydraulic turbine dynamo room, and after improve such problem point, this study has ever investigated the satisfying degree about the noise-reduction at before and after of the improvement of soundproof measure, using the Auralizational technique that can experience virtual acoustic field. It is considering that such result could be utilized usefully as the fundamental material hereafter for the acoustic performance of the hydro-electric power generator room in dam and when its construction.

Evaluation of Sound Quality for Ergonomic Design of Movable Parts in a Refrigerator (냉장고 동작부품의 소음특성 분석을 통한 감성품질 개선)

  • Kang, Seong Yeop;So, Sae Rom;Kim, Gun Ou;Kim, Ji Hoon;Park, Sang Hu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.7-15
    • /
    • 2018
  • We propose a method for evaluating sound quality quantitatively to develop high-level home appliances (HA). Generally, a refrigerator has diverse movable parts such as slider, drawer, and folding shelf. Therefore, an engineering treatment to control the noise quality is considered as one of key technologies for a higher level refrigerator. Among the movable parts, we have selected a folding shelf as an example, which is commonly setup inside of a home refrigerator for increasing space convenience, to control the noise quality. However, it is known that its noise level is very high comparing to other movable parts when folding or unfolding actions. In order to evaluate and compare the noise quality, we have tested different eighteen models, and have suggested an impact sound quality index (ISQI) based on subjective evaluation data obtained experimentally by thirty two evaluators. The ISQI was formulated using three sound quality elements (noise peak, raising time, impact duration) to determine psycho-acoustic properties. Through this work, we developed an evaluating process and ISQI that was verified the usefulness by comparing the test results of personal perceptions given by evaluators with the prediction value of ISQI. We showed a good relations between them, so we believe that the proposed method and ISQI can be utilized to control of the noise quality of HA effectively.

The Phoniatric Evaluation of the Effect of the Laryngomicrosurgery for the Laryngeal Polyps and the Nodules (성대폴립및 결절의 치료 효과에 대한 음성의학적 고찰)

  • 김기령;홍원표;김광문;이경재;정태영;이명호
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.8.2-9
    • /
    • 1983
  • Recently, the laryngomicrosurgery has been done for the removal of benign laryngeal mass and for the improvement of voice. For the evaluation of the effect of the treatment, there must be any objective method such as aerodynamic study, vocal fold vibration study, acoustic analysis, psycho-acoustic evaluation and the neuro-muscular study. The authors evaluated the phoniatric effect of the laryngomicrosurgery for the patients of 15 laryngeal polyps and 9 laryngeal nodules, who received pre-op. and post-op. vocal function study from Jun. 1981 to Mar. 1983. The results obtained were as follows ; 1) The post-op. mean value of the maximum phonation time was increased 40 % in the unilateral polyps, 62 % in the bilateral nodules and 18 % in the unilateral nodules. 2) The post-op. mean value of the phonation quotient was decreased 25 % in comparison with pre-op. value in the case of the bilateral polyps, 26 % in the unilateral polyps, 55 % in the bilateral nodules and 12 % in the unilateral nodules. 3) The post-op. mean value of the mean air flow rate was decreased 27 % in comparison with the pre-op. value in the case of the bilateral polyps, 25 % in the unilateral polyps, 65 % in the bilateral nodules, 25 % in the unilateral nodules. 4) The glottic chink of the 10 cases of polyps among the 11 cases were disappeared, and the glottic chink of the 5 cases of nodules among 7 cases were also disappeared after surgery. 5) The pre-op. hoarseness of the 10 cases of polyps among the pre-op. hoarseness of the 11 cases of polyps were changed to clear and the 3 cases of nodules were also changed to clear.

  • PDF

Phase-matched Harmonic Generation and Variable Slope Exponential Weighting for Virtual Bass System (위상 일치와 가변 지수 감쇠 가중치 부여 방법이 적용된 가상 저음 시스템)

  • Moon, Hyeongi;Park, Young-cheol;Whang, Young-soo
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.889-898
    • /
    • 2016
  • Virtual Bass System (VBS) is widely used to extend the lower frequency limit of small loudspeakers, which generates harmonics of a fundamental frequency. The perceptual quality of the VBS is highly dependent on the harmonic weighting strategy. There have been several weighting methods, including exponential attenuation and timbre matching. However, it is essential to match phases between harmonics in the original signal and generate harmonics to precisely convey the weighting strategy. This paper shows the limitations of the previous harmonic weighting schemes and proposes a new harmonic weighting scheme. The proposed weighting scheme proposes phase matching between the original and generated harmonics and varies the slope of the attenuation weighting dynamically according to the missing fundamental frequency. Objective and subjective tests show that the proposed harmonic weighting scheme provides more natural and effective bass perception in a limited situation than the conventional schemes, which implies that the phase matching is essential for the high quality bass enhancement.