• Title/Summary/Keyword: Pseudo

Search Result 3,761, Processing Time 0.029 seconds

Note on Almost Generalized Pseudo-Ricci Symmetric Manifolds

  • Baishya, Kanak Kanti
    • Kyungpook Mathematical Journal
    • /
    • v.57 no.3
    • /
    • pp.517-523
    • /
    • 2017
  • The purpose of the present paper is to study an almost generalized pseudo-Ricci symmetric manifold. The existence of such manifold is ensured by an example. Furthermore, having found, faulty example in [13], the present paper also attempts to construct a non-trivial example of an almost pseudo Ricci symmetric manifold.

Deep learning algorithms for identifying 79 dental implant types (79종의 임플란트 식별을 위한 딥러닝 알고리즘)

  • Hyun-Jun, Kong;Jin-Yong, Yoo;Sang-Ho, Eom;Jun-Hyeok, Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.196-203
    • /
    • 2022
  • Purpose: This study aimed to evaluate the accuracy and clinical usability of an identification model using deep learning for 79 dental implant types. Materials and Methods: A total of 45396 implant fixture images were collected through panoramic radiographs of patients who received implant treatment from 2001 to 2020 at 30 dental clinics. The collected implant images were 79 types from 18 manufacturers. EfficientNet and Meta Pseudo Labels algorithms were used. For EfficientNet, EfficientNet-B0 and EfficientNet-B4 were used as submodels. For Meta Pseudo Labels, two models were applied according to the widen factor. Top 1 accuracy was measured for EfficientNet and top 1 and top 5 accuracy for Meta Pseudo Labels were measured. Results: EfficientNet-B0 and EfficientNet-B4 showed top 1 accuracy of 89.4. Meta Pseudo Labels 1 showed top 1 accuracy of 87.96, and Meta pseudo labels 2 with increased widen factor showed 88.35. In Top5 Accuracy, the score of Meta Pseudo Labels 1 was 97.90, which was 0.11% higher than 97.79 of Meta Pseudo Labels 2. Conclusion: All four deep learning algorithms used for implant identification in this study showed close to 90% accuracy. In order to increase the clinical applicability of deep learning for implant identification, it will be necessary to collect a wider amount of data and develop a fine-tuned algorithm for implant identification.

Numerical Visualization of the Pseudo-Shock Waves using LES (LES를 이용한 Pseudo-Shock Waves의 가시화)

  • Deng, Ruoyu;Jin, Yingzi;Kim, Heuy Dong
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.3
    • /
    • pp.29-34
    • /
    • 2015
  • The interaction between a normal shock wave and a boundary layer along a wall surface in internal compressible flows causes a very complicated flow. This interaction region containing shock train and mixing region is called as pseudo-shock waves. Pseudo-shock waves in the divergent part of a rectangular nozzle have been investigated by using large-eddy simulation (LES). LES studies have been done for the complex flow phenomena of three-dimensional pseudo-shock waves. The LES results have been validated against experimental wall-pressure measurements. The LES results are in good agreement with experimental results. Pseudo-shock length and corner separation have been studied in three-dimensional LES model. Comparison of centerline pressure measurement and 3D visualization measurement has been discussed for the corner separation position. It has been concluded that the pseudo-shock length should be measured by using 3D visualization measurement.

Study of Multichannel Pseudo-spark Switch for High-voltage and High-current (고전압 대전류 Multichannel Pseudo-spark 스위치 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1859-1861
    • /
    • 2002
  • This paper attempts to discuss the pseudo-spark which is developed for high voltage and high current. The pseudo-spark switch is on the basic of the Paschen's law. The pseudo-spark switch fabricates the glass chamber. The pseudo-spark switch consists of hollow cathode, hollow anode, and trigger. The pseudo-spark switch is operated at the voltage of 20 kV and the pressure range of $20{\sim}80$ mtorr with He-gas. The switching current of the pseudo-spark switch was measured as 65 kA, and the duration of the pulse was about 100 ${\mu}s$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

Inhibition of Lipopolysaccharide-Induced Expression of Inducible Nitric Oxide and Cyclooxygenase-2 by Aquaous of Aconitum pseudo-laeve var. erectum in RAW 264.7 Macrophages

  • Han, Myung-Soo;Lee, Jae-Hyok;Kim, Ee-Hwa
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.678-683
    • /
    • 2008
  • Aconitum pseudo-laeve var. erectum has traditionally been used for the treatment of water retention in the body. Administration of the aqueous extract of Aconitum pseudo-laeve var. erectum has the efficiency of anti-inflammatory activity and modulates the intestinal immune system. However, the mechanism of anti-inflammatory action of Aconitum pseudo-laeve var. erectum has not been clarified yet. In the present study, the effect of Aconitum pseudo-laeve var. erectum against LPS-stimulated expressions of COX-2 and iNOS in cells of the murine RAW 264.7 macrophages was investigated using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, reverse transcription- polymerase chain reaction (RT-PCR), PGE2 immunoassay, and NO detection. The results of the present study indicate that Aconitum pseudo-laeve var. erectum is a potent inhibitor of the LPS-induced NO and $PGE_{2}$ production by blocking iNOS and $NF{\kappa}B$ activation in RAW 264.7 macrophages. These findings suggest that Aconitum pseudo-laeve var. erectum is a potential therapeutic for the treatment of inflammatory syndrome.

Seismic stability analysis of tunnel face in purely cohesive soil by a pseudo-dynamic approach

  • Huang, Qi;Zou, Jin-feng;Qian, Ze-hang
    • Geomechanics and Engineering
    • /
    • v.23 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • To give a solution for seismic stability of tunnel faces subjected to earthquake ground shakings, the pseudo-dynamic approach is originally introduced to analyze tunnel face stability in this study. In the light of the upper-bound theorem of limit analysis, an advanced three-dimensional mechanism combined with pseudo-dynamic approach is proposed. Based on this mechanism, the required support pressure on tunnel face can be obtained by equaling external work rates to the internal energy dissipation and implementing an optimization searching procedure related to time. Both time and space feature of seismic waves are properly accounted for in the proposed mechanism. For this reason, the proposed mechanism can better represent the actual influence of seismic motion and has a remarkable advantage in evaluating the effects of vertical seismic acceleration, soil amplification factor, seismic wave period and initial phase difference on tunnel face stability. Furthermore, the pseudo-dynamic approach is compared with the pseudo-static approach. The difference between them is illustrated from a new but understandable perspective. The comparison demonstrates that the pseudo-static approach is a conservative method but still could provide precise enough results as the pseudo-dynamic approach if the value of seismic wavelengths is large or the height of soil structures is small.

Estimation of Ionospheric Delays in Dual Frequency Positioning - Future Possibility of Using Pseudo Range Measurements -

  • Isshiki, Hiroshi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.185-190
    • /
    • 2006
  • The correct estimation of the ionospheric delays is very important for the precise kinematic positioning especially in case of the long baseline. In case of triple frequency system, the ionospheric delays can be estimated from the measurements, but, in case of dual frequency system, the situation is not so simple. The precision of those supplied by the external information source such as IONEX is not sufficient. The high frequency component is neglected, and the precision of the low frequency component is not sufficient for the long baseline positioning. On the other hand, the high frequency component can be estimated from the phase range measurements. If the low frequency components are estimated by using the external information source or pseudo range measurements, a more reasonable estimation of the ionospheric delays may be possible. It has already been discussed by the author that the estimation of the low frequency components by using the external information source is not sufficient but fairly effective. The estimation using the pseudo range measurements is discussed in the present paper. The accuracy is not sufficient at present because of the errors in the pseudo range measurements. It is clarified that the bias errors in the pseudo range measurements are responsible for the poor accuracy of the ionospheric delays. However, if the accuracy of the pseudo range measurements is improved in future, the method would become very promising.

  • PDF

Patterns and Usage of Pseudo Student Talk (PST) (유사학생발화의 유형과 분류)

  • Shin, Yoon-Joo;Choe, Seung-Urn
    • Journal of the Korean earth science society
    • /
    • v.29 no.1
    • /
    • pp.78-90
    • /
    • 2008
  • In most classrooms, teachers talk more than students. Teachers have been thought to be knowledge-donors and students have been thought to be knowledge-acceptors, so teacher-talks were thought to be more important than student-talks. But student-talks are very important to the students: not only to the students who speak out their opinions or answer to the questions given to them, but also to the others who say nothing in the class. Many students in Korea are not so fond of speaking out something to all the class, so some teachers are using a strategy: to say something as if he for she) is a student in the classroom. What teachers talk are not the words of the teacher-talks. They are only talked by the teachers, but they function like student-talks. To study this type of talks are needed to help both teachers and students but there are not much research about this. So in this paper we a) name it Pseudo Student Talk (PST), b) define it as 'a kind of talks that are not talked by students of the class but its functions are very similar to the student-talks', c) classify PST in 'EBS 2005 science class for 7th grade' according to types of student talks (categorized by Lemke, 1990), and d) show the usage of each kind of PST.