• 제목/요약/키워드: Proximal fracture

검색결과 252건 처리시간 0.03초

Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철 (Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth)

  • 윤형인
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

IPS-Empress 도재관의 변연형태에 따른 파절강도에 관한 연구 (A STUDY ON THE FRACTURE STRENGTH OF THE IPS-EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPE)

  • 김현수;주태훈;오상천;동진근
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.296-307
    • /
    • 1997
  • The purpose of this study was to compare the fracture strength of the IPS-Empress ceramic crown according to margin types such as bevel, shoulder, rounded shoulder, shoulder with bevel, rounded shoulder with bevel and bevel with groove. After 10 metal dies were constructed for each group, the IPS-Empress ceramic crown were fabricated and each crown was cemented on each metal die with Bistite resin cement. The cemented crowns mounted in the testing jig were inclined 30 degree and universal testing machine (Zwick 1456 41, Zwick Co., Germany) was used to measure the fracture strength. The obtained results were as follows : 1. The fracture strength of the crown with rounded shoulder was the highest of all. The mean fracture strength was 484N in rounded shoulder, 357N in bevel, 341N in rounded shoulder with bevl, 300N in shoulder with bevel, 280N in shoulder and 275N in bevel with groove. 2. The fracture strength of rounded shoulder was statistically different from those of shoulder with bevel, shoulder and beve41 with groove. 3. In the strain at fracture, there was no significant difference among each group. 4. The fracture mode of the crown was similar and most of fracture line began at the loading area and extended through proximal surface perpendicularly to the margin, irrespective of margin type.

  • PDF

해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료 (Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture)

  • 정형진
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

IPS Empress 도재관의 파절강도 : 상악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECTS OF INCISAL REDUCTION AND AXIAL INCLINATION ON UPPER CANINE)

  • 신동국;강한중;박용석;박광수;동진근
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.30-40
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction (2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper canine. Material and methods. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and the universal testing machine was used to measure the fracture strength. Results. 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest (839N) Crowns of 2.0mm depth and $12^{\circ}$ inclination had the lowest strength (559N). 2. There was no significant difference in the fracture strength by axial inclination in the same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

IPS Empress 도재관의 파절강도 : 상악 중절치에서 절단연 삭제량과 축면 경사도에 따른 영향 (Fracture strength of the IPS Empress crown :The effect of incisal reduction and axial inclination on upper central incisor)

  • 송병권;이해형;동진근
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.237-245
    • /
    • 2000
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal depth(2.0mm, 2.5mm, 3.0mm) and axial inclination($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper central incisor. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results were : 1. The fracture strength of the ceramic crown with 2.5mm depth and $8^{\circ}$ inclination was the highest(965N). Crowns of 2.0mm depth and $4^{\circ}$ inclination had the lowest strength(713N). There were no significant differences of the fracture strength by axial inclination in same incisal depth group. 2. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal depth. There had correlation between fracture strength and fractured surface area.

  • PDF

IPS Empress 도재관의 파절강도: 하악 중절치에서 절단연 삭제량과 축면 경사도에 따른 영향 (Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary Central Incisor)

  • 남영성;김계순;정영찬;김유리;동진근
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.207-217
    • /
    • 2003
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the lower central ncisor. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows : The fracture strength of the ceramic crown with 2.0mm depth and $12^{\circ}$ inclination was the highest (648 N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (482 N). There were no significant differences of the fracture strength by axial inclination in same incisal depth group. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal depth. There had correlation between fracture strength and fractured surface area.

상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고- (Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report -)

  • 지종훈;김영율;박상은;라기항;도정훈;김원유
    • 대한정형외과스포츠의학회지
    • /
    • 제6권1호
    • /
    • pp.57-65
    • /
    • 2007
  • 목적: 관절경하에서 봉합 나사못을 이용하거나 또는 도관나사못을 동반 사용하여 상완골 대결절 골절편을 고정하며 동시에 동반된 병변을 치료하여 임상적 결과를 분석하고 그 유용성을 문헌 고찰과 함께 보고하고자 한다. 대상 및 방법: 2004년 4월부터 2006년 4월까지 전위 골절, 복잡 골절, 회전 근개 파열, 견관절 구축이 나 관절 순 손상을 동반한 미세 전위된 상완골 대결절 골절 중에서 관절경하에서 봉합 나사못을 이용하거나 또는 도관나사못을 동반 사용하여 정복 및 고정을 시행한 총 7예를 대상으로 후향적으로 분석하였다. 6개월 이상 추시된 환자의 최종 운동 각도 및 ASES 및 UCLA score를 이용하여 술후 임상적 결과를 분석하였다. 결과: 임상적 결과로 평근 ASES 및 UCLA score는 술후 최종 추시 시 93.6점과 31.5점로 향상되었으며 술후 최종 추시시 평균 운동 범위는 전방거상 154.3도, 측방거상 145.8도, 외회전 32.6도, 내회전 제 1 요추 수준으로 향상되었다. 결론: 상완골 대결절 골절에서 전위된 골절이거나, 골절편이 작거나 여러개일 경우, 또는 회전근 개 파열, 견관절 구축이나 반카르트 병변등의 동반질환들이 있는 경우에는 관절경하에서 동반 병변 치료와 함께 봉합 나사못을 이용하거나 또는 도관나사 못을 동반 사용하여 대결절 골절을 고정하는 방법은 유용한 치료방법중의 하나로 생각된다.

  • PDF

IPS Empress 도재관의 파절강도 : 하악 제2소구치에서 교합면 두께와 축면 경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON LOWER SECOND PREMOLAR)

  • 김희진;이해형;남영성;동진근
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.441-450
    • /
    • 2002
  • The purpose of this study was compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the lower second premolar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement. The cemented crowns were mounted on the testing jig with inclination of 30 degrees and the universal testing machine was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (1284 N). Crowns of 1.5mm depth and $8^{\circ}$ inclination had the lowest strength (951 N). 2. There were no significant differences in the fracture strength by axial inclination of the same occlusal depth group. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth.

IPS Empress 도재관의 파절강도 : 하악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향 (Fracture Strength of IPS Empress Crown : The Effect of Incisal Reduction and Axial Inclination on Lower Canine)

  • 정영찬;신동국;박은주;김민정;동진근
    • 구강회복응용과학지
    • /
    • 제20권1호
    • /
    • pp.19-29
    • /
    • 2004
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction(2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the lower canine. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest(1377N). Crowns of 2.0mm depth and $4^{\circ}$ inclination had the lowest strength (731 N). 2. There were no significant differences of the fracture strength by axial inclination in same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

IPS Empress 도재관의 파절강도: 하악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON LOWER FIRST MOLAR)

  • 김성훈;이진한;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.48-60
    • /
    • 2003
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the lower First Molar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan). The cemented crowns were mounted on the testing jig with inclination of 30 degrees and the universal testing machine(Zwick Z020, Zwick, Germany)was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (1789 N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (1091 N). 2. There were no significant differences in the fracture strength by axial inclination of the same occlusal depth group. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth. Size of fragment was affected by the amount of occlusal reduction.