• 제목/요약/키워드: Proximal descending thoracic aorta

검색결과 37건 처리시간 0.017초

우측 하행 대동맥을 동반한 중복 대동맥궁 - 1례 수술 치험 - (Double Aortic Arch with Right Sided Descending Aorta - Report of 1 case -)

  • 조경수
    • Journal of Chest Surgery
    • /
    • 제23권1호
    • /
    • pp.201-204
    • /
    • 1990
  • The double aortic arch is the commonest anomaly among the vascular rings are relatively rare congenital vascular anomalies. This anomaly is malformation of the aortic arch system may, by compression of the trachea and esophagus, cause respiratory distress and dysphagia. We experienced one case of double aortic arch with right sided descending aorta with predominant right anterior arch treated surgically at Kyung Hee University Medical Center. 1-year-old male patient with acute airway obstruction due to combination of double aortic arch and right descending aorta. The diagnosis was made by simple X-ray & confirmed by barium esophagogram & aortogram. The operative approach was through left thoracotomy & underwent division of the left aortic arch & division of ligamentum arteriosum & suspension of divided proximal end of anterior arch to anterior thoracic wall. The postoperative courses was uneventful and doing well on the 3 years.

  • PDF

좌쇄골하동맥 기시 근위부에 발생한 대동맥교약증1 치험 (Coarctation of the aorta: unuaual type: a case report)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.12-18
    • /
    • 1984
  • Coarctation of the aorta usually occurs just distal to the origin of the left subclavian artery, but may involve proximal to this vessel. One unusual type of coarctation of the aorta which located proximal to the left subclavian artery is presented. The patient was 23 year old soldier whose primary complaints were occipital headache and dizziness. Examination showed a unilateral hypertension in the right arm. The aortogram demonstrated coarctation between the left common carotid artery and left subclavian artery. On Jun. 14, 1983, patch graft aortoplasty was performed but failed due to pliable poststenotic aortic wall. And bypass graft from origin of the left common carotid artery to the descending thoracic aorta was performed. Postoperative course was uneventful for 4 months follows up periods. We now report a unusual type of coarctation of the aorta and its surgical treatment.

  • PDF

신생아에서 심실중격결손증을 동반한 대동맥궁 결손증의 일단계 완전 교정술 -3례 치험- (One Stage Eepair of Interruption of Aortic Arch with VSD in Neonate)

  • 전희재
    • Journal of Chest Surgery
    • /
    • 제28권6호
    • /
    • pp.610-618
    • /
    • 1995
  • Three neonates with interrupted aortic arch with VSD underwent one stage repair using revised technique of cardiopulmonary bypass with short period of circulatory arrest. A left posterolateral thoracotomy was made to permit mobilization of the descending aorta and placement of polytetrafluoroethylene[PTFE graft for distal aortic perfusion. Then the patient was placed in the supine position and a median sternotomy was performed to permit the proximal dissection, VSD repair, and direct anastomosis between the ascending aorta and descending aorta. This technique has advantages to facilitate direct anastomosis between the ascending aorta and the descending aorta, to lessen circulatory arrest time, and to prevent dangerous laceration and post-operative narrowing of the thin small ascending aorta at cannulation site. There was no operative mortality but postoperative stenosis developed in one case which was relieved with balloon aortoplasty.

  • PDF

Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

  • Lee, Youngok;Kim, Gun-Jik;Kim, Young Eun;Hong, Seong Wook;Lee, Jong Tae
    • Journal of Chest Surgery
    • /
    • 제49권6호
    • /
    • pp.465-467
    • /
    • 2016
  • The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.

하행대동맥 수술의 기왕력을 가진 환자에서 발생한 대동맥궁 침투성 궤양의 파열 (Ruptured Penetrating Atherosclerotic Ulcer of the Aortic Arch in a Patient with a Previous History of Replacing the Descending Thoracic Aorta)

  • 김재범;최세영;박남희
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.647-650
    • /
    • 2008
  • 대동맥수술 후 대동맥질환의 재발은 주로 하부에 대동맥류의 형태로 나타나며 상부에 침투성 동맥경화성 궤양의 형태로 나타나는 것은 매우 드물다. 대동맥류 수술의 기왕력을 가진 환자에서 대동맥궁과 하행대동맥의 근위부에 걸쳐 발생한 침투성 동맥경화성 궤양의 파열을 완전순환정지 하에 인조혈관을 사용하여 패취봉합을 성공적으로 시행하였기에 문헌고찰과 함께 보고하는 바이다.

대동맥폐동맥 중격결손증, 개방성 대동맥관 및 우측 쇄골하동맥 이상기시를 동반한 대동맥궁 결손증 (Interrupted Aortic Arch Associated with AP Window, PDA, and Aberrant Origin of the Right Subclavian Artery from Proximal Descending Aorta [A Case Report])

  • 이정렬;노준량
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.360-370
    • /
    • 1985
  • A case of complete interruption of aortic arch with aortopulmonary window, patent ductus arteriosus, and aberrantly originated right subclavian artery from proximal descending aorta, in a four year old boy is reported in detail. This is the only reported case in Korea, who has had a successful one-stage total anatomical correction of this combination of defects. Under deep hypothermia and total circulatory arrest, aortic continuity was established using patent ductus arteriosus and anterior wall of pulmonary artery, which was anastomosed obliquely to anteromedial side of ascending aorta. Aortopulmonary window was closed using Impra patch via pulmonary arteriotomy. Then pulmonary arteriotomy was reconstructed primarily except at the junction of right pulmonary artery and main pulmonary artery, where a small piece of pericardium was used to close the defect to prevent kinking and narrowing of right pulmonary artery. Postoperative cardiac catheterization demonstrated a good reconstruction.

  • PDF

Use of Embolic Protection Devices during Hybrid Thoracic Endovascular Aortic Repair for a Shaggy Aorta: A Case Report

  • Kim, Eun Chae;Lee, Jae Hang;Chang, Hyoung Woo;Kim, Dong Jung;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.513-516
    • /
    • 2021
  • An 87-year-old man presented with a saccular aneurysm at the proximal descending thoracic aorta. As computed tomography revealed a shaggy aorta, we planned hybrid thoracic endovascular aortic repair (TEVAR) with embolic protection devices (EPDs) in both internal carotid arteries to prevent a cerebrovascular accident. We inserted an Emboshield NAV6 Embolic Protection System (Abbott Vascular, Abbott Park, IL, USA) into both internal carotid arteries before performing the TEVAR procedure. The patient was discharged from the hospital on postoperative day 4 without any neurological complications.

대동맥축착에 대한 Teflon 인조혈관 이식술 치험예 (A Successful Prosthetic Correction of Long Narrow Segment Coarctation of the Aorta: Report of A Case)

  • 김근호
    • Journal of Chest Surgery
    • /
    • 제10권1호
    • /
    • pp.90-97
    • /
    • 1977
  • This is a report of a. case in which a long narrow segment coarctation of the aorta was successfully corrected with Teflon graft. The patient was 30 year old man with hypertensive symptoms that occurred 7 years prior to operation. Blood pressure measured 230/110 mmHg in the arms and 110/80 mmHg in the legs. Pulses were strongly tensive in radial artery, but very weak in femoral artery and even absent in dorsal pedis artery. Final preoperative diagnosis was made by aortography which showed a long narrow segment between aortic arch and descending thoracic aorta and highly developed collateral circulations. A long hypoplastic narrow segment was located proximal to the ligament arteriosus, and diaphragmatic stenosis of the aorta was located just distal to the ligamentum arteriosus. After prosthetic correction of the coarctation of the aorta, blood pressure were measured 130/ 80 mmHg in the arms and 150/100 mmHg in the legs. Peripheral pulses were palpated normally, and the postoperative course was uneventful.

  • PDF

Surgical Management of Aorto-Esophageal Fistula as a Late Complication after Graft Replacement for Acute Aortic Dissection

  • Lee, Jae-Hong;Na, Bubse;Hwang, Yoohwa;Kim, Yong Han;Park, In Kyu;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • 제49권1호
    • /
    • pp.54-58
    • /
    • 2016
  • A 49-year-old male presented with chills and a fever. Five years previously, he underwent ascending aorta and aortic arch replacement using the elephant trunk technique for DeBakey type 1 aortic dissection. The preoperative evaluation found an esophago-paraprosthetic fistula between the prosthetic graft and the esophagus. Multiple-stage surgery was performed with appropriate antibiotic and antifungal management. First, we performed esophageal exclusion and drainage of the perigraft abscess. Second, we removed the previous graft, debrided the abscess, and performed an in situ re-replacement of the ascending aorta, aortic arch, and proximal descending thoracic aorta, with separate replacement of the innominate artery, left common carotid artery, and extra-anatomical bypass of the left subclavian artery. Finally, staged esophageal reconstruction was performed via transthoracic anastomosis. The patient's postoperative course was unremarkable and the patient has done well without dietary problems or recurrent infections over one and a half years of follow-up.

Next-Generation Frozen Elephant Trunk Technique in the Era of Precision Medicine

  • Suk-Won Song;Ha Lee;Myeong Su Kim;Randolph Hung Leung Wong;Jacky Yan Kit Ho;Wilson Y. Szeto;Heinz Jakob
    • Journal of Chest Surgery
    • /
    • 제57권5호
    • /
    • pp.419-429
    • /
    • 2024
  • The frozen elephant trunk (FET) technique can be applied to extensive aortic pathology, including lesions in the aortic arch and proximal descending thoracic aorta. FET is useful for tear-oriented surgery in dissections, managing malperfusion syndrome, and promoting positive aortic remodeling. Despite these benefits, complications such as distal stent-induced new entry and spinal cord ischemia can pose serious problems with the FET technique. To prevent these complications, careful sizing and planning of the FET are crucial. Additionally, since the FET technique involves total arch replacement, meticulous surgical skills are essential, particularly for young surgeons. In this article, we propose several techniques to simplify surgical procedures, which may lead to better outcomes for patients with extensive aortic pathology. In the era of precision medicine, the next-generation FET device could facilitate the treatment of complex aortic diseases through a patient-tailored approach.