• 제목/요약/키워드: Proximal contact loss

검색결과 15건 처리시간 0.027초

식편압입의 발현에 관한 임상적 연구 (A CLINICAL STUDY ON THE OCCURRENCE OF FOOD IMPACTION)

  • 정재훈;오상천;동진근
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.50-58
    • /
    • 2000
  • The purpose of this study was to investigate the causes of food impaction and to explore solutions as well. For this study, 39 patients with food impaction were selected. 77 contact areas in these patients were investigated mobility, tightness of contact area, gingival index, plaque index, attachment loss, alveolar bone loss, proximal caries, marginal ridge distance and occlusal relationships. The results were as follows ; 1. Teeth without distal support were found to be the most frequent site of food impaction (41.6%). Food impaction was found to be more frequent in the upper teeth (65.2%) than the lower teeth (33.8%). 2. Food impaction was found in tight contact cases (71.4%). Alveolar bone loss was not found in the early stage of food impaction (83.1%) 3. The distance between the marginal ridges of food impaction sites (mean=0.48mm) was short-er than that of the control group. (mean=0.77mm) (p<0.001) 4. In 18.2% of the cases, proximal carries were found at the food impaction site. 5. Food impaction affected patient's occlusion with the following frequencies, cusp to marginal ridge relationship (72.7%), cusp to fossa relationship (3.9%) and stepped relationship (23.4%).

  • PDF

임플란트 고정성 보철물 사이에서의 인접면 접촉상실: 증례보고 (Interproximal contact loss between implant-supported prostheses: a clinical report)

  • 박연희;김경아;이정진;서재민
    • 대한치과보철학회지
    • /
    • 제62권1호
    • /
    • pp.47-53
    • /
    • 2024
  • 부분 무치악 환자가 임플란트 고정성 보철물 치료를 받은 경우 interproximal contact loss (ICL)은 가장 빈번하게 발생하는 합병증이다. 일반적으로 보고되는 임플란트 보철물의 ICL은 자연치의 이동에 따른 임플란트 보철물과 자연치 사이에서 발생하는 경우가 대부분이다. 임플란트 보철물과 자연치 사이에서 발생하는 ICL의 원인은 여러가지가 있다. 임플란트 보철물 사이에서 발생하는 ICL에 대한 보고는 거의 없으며, 이는 임플란트 보철물과 자연치 사이에서 발생하는 ICL의 원인만으로는 설명하기 어렵다. 본 증례에서는 임플란트 보철물 사이에서 발생하는 ICL을 증례보고하고, 이에 대한 원인 및 대처방법을 논의하고자 한다.

직접법과 간접법으로 수복한 복합레진의 1년간의 임상적인 평가 (1 YEAR FOLLOW-UP STUDY OF DIRECT AND INDIRECT COMPOSITE RESTORATIONS)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.284-289
    • /
    • 2002
  • Background : The purpose of the present study was to evaluate the direct and indirect composite restorations which had been placed for 1 year Methods : The composite restorations which had been placed between 1999. Mar and 1999, Dec was evaluated after 1 year For direct restorations. Spectrum (Dentsply, USA) and Z100 (3M, USA) were used in the anterior teeth and Surefil (Dentsply, USA) were used. For class V restorations of anterior and posterior teeth. Spectrum was used. For indirect restorations, Targis/Vectris system (Vivadent/Ivoclar, Liechtenstein) was used 2 examiners evaluated marginal quality, proximal contact. discoloration, presence of 2$^{nd}$ caries, loss of filling and hypersensitivity of restorations. The restorations was clinically evaluated by modified methods based on USPHS. Results : 60 teeth were evaluated. 59 were clinically acceptable and 1 restoration which was placed in class v cavity in the posterior tooth was fallen out. In most cases, the restorations were clinically accept-able. For restorations which had been directly placed in the class II cavities, loose proximal contact was indicated as the main complaints. Conclusions : Most of Anterior and posterior restorations which bad been directly or indirectly placed for 1 year were clinically acceptable. For posterior teeth, loose proximal contact was indicated as the main problem in the directly placed Class II restorations. Long term clinical study is needed.

제1대구치(第一大臼齒)의 맹출양장(萌出樣狀)에 관(關)한 연구(硏究) (THE STUDIES ON THE ERUPTION PATTERN OF FIRST PERMANENT MOLARS)

  • 손동수
    • 대한소아치과학회지
    • /
    • 제3권1호
    • /
    • pp.7-11
    • /
    • 1976
  • The author measured the degree of development and the eruption pattern of first permanent molars with orthopantomography in 553 Korean children(male; 302, female; 251) from 4 to 9 years old. The orthopantomographs were obtained from dept. of pedodontics, college of dentistry, Seoul National University. The results of the studies were as follows: 1. Upper first permanent molars were erupted with distal inclination of about 30 degrees in the early stage and they gradually moved in the mesial direction by bodily movement of the tooth to be in contact with the disto-proximal surface of primary secondary molars in the late stage. 2. Lower first permanent molars were erupted with mesial inclination in the early stage and moved mesially by tipping movement of the tooth to be in contact with the disto proximal surface of the second primary molars in the late stage. 3. The eruptive forces were considered to be main etiologic factors of space closure after the premature loss of primary molars.

  • PDF

개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향 (Effect of open proximal contact on adjacent tooth and implant)

  • 문소현;김광윤;조성현;송주헌;김희중
    • 구강회복응용과학지
    • /
    • 제38권1호
    • /
    • pp.9-17
    • /
    • 2022
  • 목적: 이 연구의 목적은 개방된 인접면 접촉이 인접하는 자연치와 임플란트에 어떠한 영향을 주는지 알아보고자 하였다. 연구 재료 및 방법: 조선대학교 치과병원에서 2008부터 2018년 사이에 개방된 인접면 접촉으로 제작된 구치부 임플란트 수복물을 장착한 환자 중에서 유지관리기간이 최소 3년 이상이고 인접하는 자연치아가 건강하면서 대합치가 고정성 수복물인 임플란트를 20개 선정하여 실험군(Group A)으로 하였다. 동일한 선정기준 하에 같은 기간 통상적인 방법으로 제작된 구치부 임플란트 20개를 대조군(Group B)으로 하였다. 두 그룹사이에 임플란트와 접하는 자연치의 우식, 식편압입, 임플란트의 변연골 상실을 비교 평가하였다. 결과: Group A과 Group B 사이에 치아우식과 식편압입 및 변연골 흡수의 발생빈도는 통계학적으로 유의성이 없었다. Group A와 Group B의 평균 변연골 흡수양은 각기 0.80 ± 0.39 mm, 1.1 ± 0.43 mm였으며, 두 그룹사이에 통계학적으로 유의한 차이가 있었다. 결론: 이 실험의 결과내에서, 개방된 인접면 접촉을 가진 임플란트 보철은 인접하는 자연치와 임플란트에 어떠한 유해한 영향을 주지 않으므로 선택적인 상황에서 임상에 적용할 수 있을 것으로 사료된다.

Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철 (Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth)

  • 윤형인
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

Evaluation of adjacent tooth displacement in the posterior implant restoration with proximal contact loss by superimposition of digital models

  • Jo, Deuk-Won;Kwon, Min-Jung;Kim, Jong-Hee;Kim, Young-Kyun;Yi, Yang-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.88-94
    • /
    • 2019
  • PURPOSE. This study was conducted to investigate patterns of adjacent tooth displacement in the posterior implant with interproximal contact loss (ICL) by 3-D digital superimposition method. MATERIALS AND METHODS. Posterior partially edentulous patients, restored with implant fixed partial prostheses before 2011 and suffered from food impaction of ICL between 2009 and 2011, were included. Two dental casts, at the time of delivery and at the time of food impaction in a same patient, was converted into 3-D digital models through scanning and superimposition was performed to assess chronologic changes of the dentition. Directions of tooth displacement were evaluated and the amount of ICL was calculated. Correlations between the amount of ICL and elapsed time, or between the amount of ICL and age after function, were assessed at a significance level of P<.05. RESULTS. A total number of 13 patients (8 males, 5 females) with a mean age of $65.76{\pm}9.94years$ and 17 areas (4 maxillae, 13 mandibles) were included in this retrospective study. Teeth adjacent to the implant restoration showed complex displacements but characteristic tendency according to the location of the arch. The mean amount of ICL was $0.33{\pm}0.14mm$. Elapsed time from function to ICL was $61.47{\pm}31.27months$. There were no significant differences between the amount of ICL and elapsed time, or age (P>.05). CONCLUSION. Natural teeth showed various directional movements to result in occlusal change in the arch. The 3-D superimposition of chronologic digital models was a helpful method to analyze the changes of dentition and individual tooth displacement adjacent to implant restoration.

한국인 구치열에서 치간유두 존재와 치아접촉점과 치간골 거리와의 관계 (Relationship between Interdental Papilla Existence & Distance from Interdental Alveolar Crest to Contact Point in the Posterior Dentition of Korean adults)

  • 김현철;전용선;장문택;김형섭;박정미
    • Journal of Periodontal and Implant Science
    • /
    • 제31권3호
    • /
    • pp.625-631
    • /
    • 2001
  • The anatomic structure around interproximal area plays an important role not only in the natural teeth, but also in the implant. The loss of papilla can lead to cosmetic deformity, phonetic problem, food impaction on the anterior dentition, and masticatory problem, food impaction and proximal caries on the posterior dentition. The purpose of this study was to evaluate the relationship between interdental papilla existence and distance from contact point to alveolar crest in Korean posteior dentition. 45 Korean adult patients(31males, 14 females) participated in this study. Measurements were carreid out total 126 interproximal areas, 18 first premolar, 31 second premolar, 40 first molar, and 37 second molar areas. Papilla index was recorded as suggested by Jemt. Distance between contact point and alveolar crest measrued by Florida $probe^{R}$, after flap elevation. Each distance was measured 10 times by every 0.1mm unit. The results showed that the mean Papilla index 1.37 and mean distance between contact point and alveolar crest was 7.44mm. The correlation between the Papilla index and distance was high negative correlation(Pearson correlation=-0.47), and it was statistically significant(P=0.000) When the distance between contact point and alveolar crest was 5mm, the loss of papilla was appeared almost in half cases. When the distance was 6mm, the papilla loss was present 95%, when 7mm, the papilla loss was 100%.

  • PDF

금합금 연마재 종류에 따른 금합금 소실량과 연마 정도 (THE AMOUT OF LOSS AND THE DEGREE OF SURFACE SMOOTHNESS OF GOLD ALLOY BY GOLD ALLOY POLISHING RUBBER POINT MATERIALS)

  • 김명화;임순호;정문규
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.277-295
    • /
    • 1997
  • After clinical adjustment of dental casting restoration, re-polishing procedure is recommanded because the smooth gold sureface is lost. But there is the possibility to get more loose contact than that intended by loss of gold alloy according to the kinds of polishing materials and polishing time. Therefore in this study I polished type II gold alloy with 390gm force, 20,000rpm speed, and 8 kinds of gold alloy polishing materials, fabricated by 4 companies and then measured the amount of loss of gold alloy with Surfcorder SEF-30D and observed alloy surfaces polished by 3 brown rubber points with SEM. The amount of loss of gold alloys polished with 8 kinds of polishing materials and the degree of smoothness of gold alloys according to polishing time and polishing materials were compared. The following results were obtained : 1. When the amount of loss of gold alloys polished with 3 kinds of brown rubber point was compared, Alphalex brown point had the most amount of alloy loss, followed in decreasing order by Shofu brown point and Eveflex brown point. There was statistically significant difference in the amount of alloy loss according to polishing materials. 2. When the amount of loss of gold alloys polished with 5 kinds of green rubber point was compared, Shofu green point had the most amount of alloy loss, followed in decreasing order by Alphaflex green point, Dedeco green clasp polisher, and Eveflex green point. There was statistically significant difference in the amount of alloy loss according to polishing materials except Alphaflex green point and Dedeco green clasp polisher. 3. When the amount of loss of gold alloys polished with all kinds of rubber point was compared, there was no significant difference in Eveflex brown point, Alphaflex green point, and Dedeco green clasp polisher. 4. When average amount of alloy loss per 1 revolution by polishing materials was compared, Alphalex brown point had the greatest value as $0.329{\mu}m$ and Shofu supergreen point had the lowest value as $0.022{\mu}m$. 5. When the degree of sureface smoothness of gold alloy polished with 3 kinds of brown rubber point was compared, In Alphalex brown point surface roughness was completely lost after 20 seconds polishing time, in Shofu brown point 30 seconds, in Eveflex brown point 40 seconds. But in every gold alloys fine scratch formed by rubber points was observed. Based on the results of this study, as rubber polishing materials used in polishing of dental casting restoration after clinical adjustment influenced on the tightness of occlusal or proximal contact, we should make dental casting restoration with minimum error through careful laboratory procedure and form very smooth surface of restoration with tripoli and rouge after use of silicone polishing materials.

  • PDF

65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술 (Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years)

  • 이기원;최영준;안형선;김정환;황재광;강정호;추한호;박준석;김태경
    • Clinics in Shoulder and Elbow
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2012
  • 목적: 65세 이상의 상완골 근위부 골절 환자에 대하여 다축 각안정 잠김 압박 금속판 (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB)을 이용하여 내고정술을 시행하고 그 임상적, 방사선적 결과를 알아보고자 하였다. 대상 및 방법: 2007년 8월부터 2011년 1월까지 65세 이상의 상완골 근위부 골절 환자 중 NCB 금속판을 이용하여 내고정술을 시행한 32명의 환자를 대상으로 하였다. 평균 연령은 71세 였으며 평균 추시 기간은 11.5개월이였다. 골절의 분류는 2분 골절이 14예, 3분 골절이 18예였다. 임상적 평가는 VAS 점수와 Constant 점수를 이용하였으며, 방사선학적 평가는 골유합 시기와 Paavolainen 방법으로 경간각을 평가하였다. 결과: 최종 추시 시 VAS 점수는 평균 3점, Constant 점수는 평균 64.5점이었으며 모든 예에서 수술 후 평균 16.2주에 골유합을 얻었다. 방사선학적 평가 결과 최종 추시 시 경간각은 평균 125.9도로 우수 24예, 양호 8예이었다. 강선 파열 1예 및 지연유합 1예, 경미한 금속판의 견봉하 충돌로 인한 통증 호소 3예 등의 합병증이 관찰되었으며 정복소실, 나사 이완, 불유합, 상완골 골두의 무혈성 괴사 등은 없었다. 결론: NCB 금속판을 이용한 내고정술은 골절의 고정 및 정복의 유지가 어려운 고령의 상완골 근위부 골절 환자의 치료에 효과적인 수술 방법 중 하나로 생각된다.