• Title/Summary/Keyword: Proton exchange

Search Result 620, Processing Time 0.029 seconds

Proton Conductivity Measurement Using A.C. Impedance Spectroscopy for Proton Exchange Membrane

  • Lee, Chang Hyun;Park, Ho Bum;Lee, Young Moo
    • Korean Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The impedance and the subsequent proton conductivity of Nafion$\^$/ membranes as standard samples were measured and compared via the two-probe method and the four-probe method using the prepared impedance measurement system. The different impedance behavior for the same membrane was observed at the fully hydrated state in the Nyquist impedance plot. The effect of the humidity and the temperature on the proton conduction through a membrane was investigated and compared with two different cell configurations.

Problems and Solutions of Anion Exchange Membranes for Anion Exchange Membrane Fuel Cell (AEMFC) (음이온교환막연료전지용 음이온교환막의 문제점과 해결방안)

  • Son, Tae Yang;Kim, Tae Hyun;Kim, Hyoung Juhn;Nam, Sang Yong
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.489-496
    • /
    • 2018
  • Fuel cells are seen as eco-friendly energy resources that convert chemical energy into electrical energy. However, proton exchange membrane fuel cells (PEMFCs) have problems such as the use of expensive platinum catalysts for the reduction of conductivity under high temperature humidification conditions. Thus, an anion exchange membrane fuel cell (AEMFC) is attracting a great attention. Anion exchange fuel cells use non - Pt catalysts and have the advantage of better efficiency because of the lower activation energy of the oxygen reduction reaction. However, there are various problems to be solved including problems such as the electrode damage and reduction of ion conductivity by being exposed to the carbon dioxide. Therefore, this mini review proposes various solutions for different problems of anion exchange fuel cells through a wide range of research papers.

Review on Proton Exchange Membranes for Microbial Fuel Cell Application (미생물 연료 전지 적용을 위한 양성자 교환막에 대한 검토)

  • Kim, Ji Min;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.213-227
    • /
    • 2020
  • As unrenewable energy resources have depleted over the years, the demand for renewable energy has increased promoting research for more effective methods to produce renewable energy. The field of fuel cell development, specifically microbial fuel cells (MFCs), has developed because of the dual performance potential of the technology. MFCs convert power by facilitating electrode-reducing organisms such as bacteria (microbes) as a catalyst to produce electrical energy. MFCs use domestic and industrial wastewater as fuel to initiate the process, purifying the wastewater as a result. Proton exchange membranes (PEM) play a crucial role in MFCs as a separator between the anodes and cathodes chambers allowing only protons to effectively pass through. Nafion is the commercially used PEM for MFCs, but there are many setbacks: such as cost, production time, and less effective proton conductivity properties. In this review there will be largely two parts. Firstly, several newly developed PEM are discussed as possible replacements of Nafion. Secondly, MFC based on PEM, blended PEM and composite PEM are summarized.

Kinetic Study of Proton Exchange between Al($H_2O$)$_6^{3+}$ Ion and Bulk Water Molecules (Ⅰ) (Al($H_2O$)$_6^{3+}$ 이온과 물 용매 분자 사이에서의 수소 이온 교환의 반응속도론적 연구 (Ⅰ))

  • Moon-Hwan Cho;Jin-Ho Kim;Chang-Ju Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.436-442
    • /
    • 1988
  • The $^1H-nmr$ lineshapes of $H_2O$ in the solution containing $Al^{3+}$ ion have been measured as a function of temperature and $H^+$-ion concentration. Above [$H^+$] = 0.06, the lineshape were analyzed by the uncoupled two-site exchange model. From the proton exchange rate between hexaaquaaluminium ion and bulk water as a function of H-ion concentration. These kinetic data could be fitted to a following linear rate law; that is; 1/${\tau}$ = k$_1$/12 + $k_2$[$H^+$]/6. The following proton exchange parameters were obtained; $k_1^{298}$ = 38.5s$^{-1}$ ${\{Delta}H_1^{\neq}$ = $42.9kJ mole^{-1}$ ${\{Delta}S_1^{\neq}$ = -48.6J $mole^{-1}K^{-1}$ $k_2^{298}$ = $172s^{-1}mole^{-1}$ ${\{Delta}H_2^{\neq}$ = 27.8kJ $mole^{-1}$ ${\{Delta}S_2^{\neq}$ = -90.3J $mole^{-1}K^{-1}$ These activation parameters are indicating an associative interchange, Ia, mechanism for the acid-hydrolysis of hexaaquaaluminium ion and the proton exchange between the hydration spheres of $Al^{3+}$ and $H^+$.

  • PDF

SPECTRAL DIAGNOSTICS OF NON-THERMAL PARTICLES IN THE SOLAR CHROMOSPHERE

  • FANG C.;XU Z.;DING M. D.
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.55-61
    • /
    • 2003
  • There are at least three effects of the non-thermal particle bombardment on the solar atmosphere: (1) non-thermal ionization and excitation; (2) proton-hydrogen charge exchange; (3) impact line polarization. Due to the non-thermal ionization and excitation effects of electron bombardments in flares, H$\alpha$ line is widely broadened and shows a strong central reversal. Significant enhancements at the line wings of Ly$\alpha$ and Ly$\beta$ are also predicted. In the case of proton bombardment, less strong broadening and no large central reversal are expected. However, due to proton-hydrogen charge exchange, the enhancements at the red wings of Ly$\alpha$ and especially of Ly$\beta$ lines at the early impulsive phase of flares are significant. Electron beam can also in some cases generates visible and UV continuum emission in white-light flares. However, at the onset phase, a negative 'black' flare may appear in several seconds, due to the increase of the $H^-$ opacity. The impact polarization of atomic lines can provide complementary information on the energetic particles, the energy transport and deposit in the solar chromosphere. New results of spectropolarimetric analysis for the major flare on July 23, 2002 are also given in the paper.

Preparation and characterization of proton exchange membranes in non-aqueous conduction (무수 전도성 양성자 교환막 제조 및 특성평가)

  • Park, Jin-Soo;Sekhon, S.S.;Baek, Ji-Suk;Yang, Tae-Hyun;Kim, Chang-Soo;Yim, Sung-Dae;Park, Gu-Gon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.282-285
    • /
    • 2009
  • This study presents preparation and characterization of composite membranes based on ionic liquids. The ionic liquids act as water in sulfonated membranes. On the behalf of ionic conduction through ionic liquid inside the membranes, non-aqueous membranes showed Arrenhius dependence on temperature with no external humidification. It was implied that hopping mechanism of proton was dominant in the ionic liquid based membranes. In addition, small angle X-ray (SAXS) studies provided the information on morphology of ionic clusters formed by the interaction between sulfonic acid groups of the polymers and ionic liquids. The SAXS spectra showed matrix peaks, ionomer peaks and Prodo's law for Nafion based composite membranes and only matrix peaks for hydrocarbon based ones. However, ionic conductivity and atomic force microscopy (AFM) images showed the clear formation of ionic clusters of the hydrocarbon based composite membranes. It implies for ionic liquid based high temperature membranes that it is important to use sulfonated polymers as solid matrix of ionic liquid which can form clear ionic clusters in SAXS spectra.

  • PDF