New algorithm to estimate proton beam range for multi-slit prompt-gamma camera

  • Ku, Youngmo;Jung, Jaerin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3422-3428
    • /
    • 2022
  • The prompt gamma imaging (PGI) technique is considered as one of the most promising approaches to estimate the range of proton beam in the patient and unlock the full potential of proton therapy. In the PGI technique, a dedicated algorithm is required to estimate the range of the proton beam from the prompt gamma (PG) distribution acquired by a PGI system. In the present study, a new range estimation algorithm was developed for a multi-slit prompt-gamma camera, one of PGI systems, to estimate the range of proton beam with high accuracy. The performance of the developed algorithm was evaluated by Monte Carlo simulations for various beam/phantom combinations. Our results generally show that the developed algorithm is very robust, showing very high accuracy and precision for all the cases considered in the present study. The range estimation accuracy of the developed algorithm was 0.5-1.7 mm, which is approximately 1% of beam range, for 1×109 protons. Even for the typical number of protons for a spot (1×108), the range estimation accuracy of the developed algorithm was 2.1-4.6 mm and smaller than the range uncertainties and typical safety margin, while that of the existing algorithm was 2.5-9.6 mm.

전신 피부 전자선 치료(TSET)에서 EBT2 필름을 사용한 선량측정 (Dosimetry by Using EBT2 Film for Total Skin Electron Beam Therapy (TSET))

  • 황의중;라정은;정호진;안성환;김동욱;이상엽;임영경;윤명근;신동호;이세병;박성용;표홍렬;정원규
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.60-69
    • /
    • 2010
  • 전신 피부 전자선 치료(total skin electron beam therapy, TSET)를 위해서는 흔히 행해지는 일반적인 방사선 치료와 달리 치료 전 다양한 조건에서의 선량 측정과 더불어, 치료 중 지속적인 환자 신체부위별 선량 측정이 요구된다. 본 연구에서는 선형 가속기에 기반한 modified Stanford Technique으로 전신 피부 전자선 치료를 할 때 치료에 필요한 치료 전자선의 에너지와 선량의 공간적 분포 및 치료 중 환자의 각 부위별 조사선량을 EBT2 필름을 이용하여 측정 하였다. 전자선의 에너지는 이온전리함으로 측정한 값과 비교하였을 때 잘 일치하였고, 선량의 공간 분포 및 환자 각 신체부위에서의 선량 분포는 EBT2 필름을 이용하여 편리하게 측정할 수 있었다. 또한 TSET 치료중 EBT2 필름을 사용하여 in-vivo로 측정된 환자 신체 부위별 선량분포의 변화는 열형광선량계(thermoluminescent dosimeter, TLD)로 동시에 측정한 값과 비교하였을 때 잘 일치함을 알 수 있었다. 이로써 EBT2 필름의 전신 피부 전자선 치료를 위한 선량계로서의 가능성을 확인하였다.

Evaluation of Hitachi 3D Treatment Planning version 1.6

  • Fukuda, Shigekazu;Yokohama, Noriya;Maruyama, Ichiro;Kume, Kyo;Kagiya, Go;Yamamoto, Kazutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.298-299
    • /
    • 2002
  • WERC (Wakasa Wan Energy Research Center) has started the proton cancer therapy since June 2002. We use Hitachi 3D treatment planning (version 1.6) that can calculate the proton dose distribution by use of the pencil beam algorithm as well as the broad beam algorithm practically fast. This treatment planning software satisfies almost functions required in the proton therapy and includes some advanced techniques such as the 3D region glowing function that can search the target region three-dimensionally based on the CT-values. In this paper, we will introduce this planning system and present our evaluation from point of view of both clinical usage and QA.

  • PDF

Evaluation of the effect of mechanical deformation on beam isocenter properties of the SC200 scanning beam delivery system

  • Wang, Ming;Zheng, Jinxing;Song, Yuntao;Li, Ming;Zeng, Xianhu
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.2064-2071
    • /
    • 2020
  • For proton pencil beam scanning (PBS) technology, the accuracy of the dose distribution in a patient is sensitive to the properties of the incident beam. However, mechanical deformation of the proton therapy facility may occur, and this could be an important factor affecting the proton dose distribution in patients. In this paper, we investigated the effect of deformation on an SC200 proton facility's beam isocenter properties. First, mechanical deformation of the PBS nozzle, L-shape plate, and gantry were simulated using a Finite Element code, ANSYS. Then, the impact of the mechanical deformation on the beam's isocenter properties was evaluated using empirical formulas. In addition, we considered the simplest case that could affect the properties of the incident beam (i.e. if only the bending magnet (BG3) has an error in its mounting alignment), and the effect of the beam optics offset on the isocenter characteristics was evaluated. The results showed that the deformation of the beam position in the X and Y direction was less than 0.27 mm, which meets the structural design requirements. Compared to the mechanical deformation of the L-shape plate, the deformation of the gantry had more influence on the beam's isocenter properties. When the error in the mounting alignment of the BG3 is equal to or more than 0.3 mm, the beam deformation at the isocenter exceeds the maximum accepted deformation limits. Generally speaking, for the current design of the SC200 scanning beam delivery system, the effects of mechanical deformation meet the maximum accepted beam deformation limits. In order to further study the effect of the incident beam optics on the isocenter properties, a fine-scale Monte Carlo model including factors relating to the PBS nozzle and the BG3 should be developed in future research.

Linear Energy Transfer Dependence Correction of Spread-Out Bragg Peak Measured by EBT3 Film for Dynamically Scanned Proton Beams

  • Lee, Moonhee;Ahn, Sunghwan;Cheon, Wonjoong;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.135-144
    • /
    • 2020
  • Purpose: Gafchromic films for proton dosimetry are dependent on linear energy transfers (LETs), resulting in dose underestimation for high LETs. Despite efforts to resolve this problem for single-energy beams, there remains a need to do so for multi-energy beams. Here, a bimolecular reaction model was applied to correct the under-response of spread-out Bragg peaks (SOBPs). Methods: For depth-dose measurements, a Gafchromic EBT3 film was positioned in water perpendicular to the ground. The gantry was rotated at 15° to avoid disturbances in the beam path. A set of films was exposed to a uniformly scanned 112-MeV pristine proton beam with six different dose intensities, ranging from 0.373 to 4.865 Gy, at a 2-cm depth. Another set of films was irradiated with SOBPs with maximum energies of 110, 150, and 190 MeV having modulation widths of 5.39, 4.27, and 5.34 cm, respectively. The correction function was obtained using 150.8-MeV SOBP data. The LET of the SOBP was then analytically calculated. Finally, the model was validated for a uniform cubic dose distribution and compared with multilayered ionization chamber data. Results: The dose error in the plateau region was within 4% when normalized with the maximum dose. The discrepancy of the range was <1 mm for all measured energies. The highest errors occurred at 70 MeV owing to the steep gradient with the narrowest Bragg peak. Conclusions: With bimolecular model-based correction, an EBT3 film can be used to accurately verify the depth dose of scanned proton beams and could potentially be used to evaluate the depth-dose distribution for patient plans.

Geant4 몬테카를로 코드를 이용한 양성자 치료기 노즐의 전산모사 (A Monte Carlo Simulation Study of a Therapeutic Proton Beam Delivery System Using the Geant4 Code)

  • 신정욱;심현하;곽정원;김동욱;박성용;조관호;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.226-232
    • /
    • 2007
  • 국립암센터에 설치된 양성자 치료기의 빔 전달 시스템에 대하여 Geant4 코드를 이용하여 몬테카를로 전산모사를 수행하였고, 선량검증 도구로써의 이용 가능성에 대하여 연구하였다. 몬테카를로 기술을 기반으로 하는 선량계산은 물질내의 선량분포를 이해하는 데 가장 정확한 방법으로 알려져 있다 외부조사 방사선치료에 있어서 이 방법의 장점을 극대화 하기 위해서는, 빔이 지나가는 곳에 놓여진 노즐 구성요소들의 정확한 모델링과 더불어 초기빔 특성파악은 무엇보다 중요하다. 국립암센터에 설치된 양성자 치료기는 총 3가지 형태-double/single scattering, uniform scanning and pencil-beam scanning-로 치료빔을 조사할 수 있으며, 본 연구진은 Geant4.8.2 코드를 기반으로 double/single scattering 모드를 구성하는 모든 노즐구성요소들에 대하여 모델링 하였다. 특정 치료감이에 대하여 실험치와 일치하는 전산모사의 결과를 얻었다 본 기관에 설치된 양성자치료기에 대한 몬테카를로 전산모사에 대한 기반을 성공적으로 구축하였고, 치료빔에 대하여 정밀한 선량측정에 이용할 수 있다. 치료빔의 전 에너지 영역에 걸쳐 추가적인 커미셔닝을 수행할 것이다.

  • PDF

Preliminary Molecular Dynamics Simulations of the OSS2 Model for the Solvated Proton in Water

  • 이송희
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.847-849
    • /
    • 2001
  • The OSS2(Ojame-Shavitt-Singer 2)[L. Ojame et al., J. Chem. Phys. 109, 5547 (1998)] model as a dissociable water model is examined in order to study the dynamics of H+ in water. MD simulations for 216 water system, 215 water + H+ ion system, and 215 water + OH- ion system using the OSS2 model at 298.15 K with the use of Ewald summation are carried out. The calculated O-H radial distribution functions for these systems are essentially the same and are in very good agreement with that obtained by Ojame.

채널 내장형 습도 센서를 이용한 고분자 전해질 연료전지의 습도분포 측정 (Measurement of Humidity Distribution in a Proton Exchange Membrane Fuel Cell Using Channel Embedded Humidity Sensors)

  • 이용택;양경열
    • 대한기계학회논문집B
    • /
    • 제39권5호
    • /
    • pp.397-403
    • /
    • 2015
  • 본 연구는 고분자 전해질 연료전지 (PEMFC)의 성능에 매우 중요한 영향을 미치는 물의 분포를 실험적으로 측정하였다. 내부에서 일어나는 활발한 화학반응과 물질전달 특성 때문에 PEMFC 내부에서 수분의 분포가 불균일하며 그 분포를 실험적으로 측정하기가 용이하지 않아 그 동안 간접적인 측정이 많이 이루어졌다. 본 연구에서는 초소형 온습도 센서를 연료전지의 채널에 직접 삽입하고 채널을 따라 흐르는 반응가스의 습도를 측정하였다. 수소극과 공기극 중 한곳만 가습하며, 가습하지 않은 곳에서 습도를 측정하여 멤브레인을 통한 물의 이동을 연구하였다. 가습기의 온도가 증가할수록 양극의 물농도 구배가 커져서 확산이 증가하나 높은 전류밀도에서는 전기삼투항력의 영향이 더욱 커졌다.

Off-line PET-CT를 이용한 양성자치료에서의 Range 검증 (Analysis of the Range Verification of Proton using PET-CT)

  • 장준영;홍건철;박세준;박용철;최병기
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.101-108
    • /
    • 2017
  • 목 적: 양성자치료에 이용되는 양성자선은 종양 부위 앞에 있는 정상 조직에는 적은 선량을 주는 반면 암 조직 부위에서는 브래그 피크(Bragg peak)를 형성하며 최대 선량을 주고 바로 소멸하는 특징을 가지고 있으며 양성자치료의 장점을 극대화하기 위해서는 양성자의 도달 위치 검증이 매우 중요하다. 본 연구에서는 Off-line PET CT 방법을 이용하여 양성자 조사 후 양성자 궤적을 따라 생성된 11 C(반감기=20분), 150(반감기=2분), 13N (반감기=10분) 등의 핵자에서 방출되는 양전자의 분포를 측정하여 양성자의 Range와 Distal falloff 지점을 검증하게 되었다. 대상 및 방법: IEC 2001 Body 팬텀안에는 37 mm, 28 mm, 22 mm 구체를 삽입할 수 있게 구성되어 있으며 팬텀안에 물을 가득 채워 각 구체크기별로 CT image를 획득하였고 양성자의 Range와 Distal falloff 지점을 검증하기 위하여 양성자치료계획시스템으로 각 구체 크기 별로 37 mm 구체에서 46 mm, 28 mm에서 37 mm, 22 mm 구체에서 33 mm의 SOBP를 설정하였고, Scanning 방법으로 Gantry 0도의 Single beam으로 동일한 센터에서 양성자를 조사하였다. 조사된 팬텀은 PET-CT 장비를 이용하여 스캔하였고, PET-CT 영상획득방법은 1분씩 50개의 영상을 획득하여 팬톰 내의 구체를 포함하여 4개의 ROI를 설정한 후 10개씩 영상을 합산하여 재구성 하였다. 치료계획 시 수립한 구체크기에 따른 Dose profile과 비교하기 위하여 Depth에 따른 Activity profile로 나타냈다 결 과: 37 mm, 28 mm, 22 mm 구체에서 모두 Distal falloff position 에서 Dose profile과 같이 PET-CT의 Activity profile 역시 급격히 감소하는 양상을 나타냈다. 하지만 Range를 평가하는 구간인 SOBP구간에서는 Activity profile의 경우 Proximal 부분에서의 측정치가 Dose profile 양상과 다른 결과가 나왔으며, Distal falloff position을 구체 크기별로 양성자 치료계획과 PET-CT 측정치와의 차이를 비교해 본 결과 37 mm 구체에서는 Max dose의 50 % 지점에서 최대 1.4 mm, 28 mm 구체에서는 45 % 지점에서 최대 1.1 mm, 22 mm 구체에서의 차이는 40 % 지점에서 최대 1.2 mm로 모두 1.5 mm 미만의 차이를 보였다. 결 론: 양성자치료의 장점을 최대한 활용하기 위해서는 양성자빔의 Range를 검증하는 것이 매우 중요하다. 본 연구에서는 PET-CT 장비를 이용하여 양성자빔의 SOBP 와 Distal falloff 위치를 통해 양성자 Range를 확인하였고 그 결과 PET-CT 장비를 이용해 측정한 Activity 분포와 양성자 치료계획과의 Distal falloff position의 차이는 1.4 mm 내에서 일치함을 확인하였다. 이는 본원에서 양성자치료계획 시 적용하는 선량마진에 참고자료로 활용될 수 있을 것으로 사료된다.

  • PDF

Geant4 전산모사를 이용한 종양의 밀도 변화에 따른 양성자의 선량 분포 (Depth Dose Distribution of Proton Beams by Variation of Tumor Density using Geant4)

  • 김유미;천권수
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.771-779
    • /
    • 2021
  • 단일 에너지의 양성자 선원은 좁은 브래그 피크를 형성하므로 종양의 치료 범위를 포함하기 위해서는 여러 개의 피크를 중첩하여 확산된 브래그 피크를 형성한다. 선행 연구에서는 뇌종양의 밀도를 뇌 조직과 동일하게 구성하여 종양의 흡수선량을 계산하였다. 그러나 종양의 밀도는 일정한 값이 아니므로 본 연구는 몬테카를로 방법의 Geant4 전산모사를 이용하여 종양의 밀도 변화에 따른 양성자 선원의 확산된 브래그 피크를 평가하였다. 뇌 조직 팬텀을 구성하여 치료 범위를 고려하여 종양의 크기를 10 mm와 20 mm로 선택하였다. 종양의 위치와 크기에 맞는 확산된 피크를 형성하기 위하여 수학적 방법을 이용하여 양성자 선원의 에너지와 상대적 강도를 계산하였다. 종양의 밀도가 높아질수록 SOBP의 95% 선량 구간과 실정 비정은 감소하였으며 95% 선량 구간의 평균 흡수선량은 증가하였다. 종양의 밀도 증가는 양성자 선원의 선량 분포에 영향을 주어 종양의 크기보다 작은 확산된 브래그 피크를 형성하였다. 종양의 밀도 반영은 비정을 결정하는데 영향을 주어 치료구간의 여유 마진(margin)을 최소화하여 양성자 치료의 장점을 최대로 활용할 수 있을 것이다.