• Title/Summary/Keyword: Proton Treatment

Search Result 263, Processing Time 0.021 seconds

Simultaneous Spectrophotometric Determination of Cr(Ⅲ) and Cr(Ⅳ) in Chromium Plating Solution via Flow-Through Analysis (흐름계를 이용한 크롬도금 용액의 Cr(Ⅲ)와 Cr(Ⅵ)의 분광학적 동시 분석 방법)

  • Kim, Sun Kwan;Nam, Hakhyun;So, Jae Chun;Lee, Won;Cha, Geun Sig;Han, Sang Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.2
    • /
    • pp.87-93
    • /
    • 1995
  • The amount of Cr(Ⅲ) and Cr(Ⅵ) in a chromium plating solution could be determined simultaneously within five minutes using UV/VIS spectrophotometer coupled with a flow-through analysis(FTA) setup. The λmax's at 580 nm and 440 nm which correspond to Cr(Ⅲ) and Cr(Ⅵ), respectively, well obey the Beer-Lambert law in the range over 0.05 g/L for Cr(Ⅲ) and 0.005 g/L for Cr(Ⅵ). when the pH of the sample is less than 4.0, the absorption extinction coefficients of those peaks are not much dependent on the proton concentration. The amount of Cr(Ⅲ) and Cr(Ⅵ), and the total chromium in post treatment chromium plating solution, which normally has few g/L of Cr concentration, could be easily measured using UV/VIS spectrophotometry after the sample had been diluted with sulfuric acid of pH=1.0 in the flow-through analysis setup; this method is far more convenient and faster than the common redox titration (which requires at least 40 min/sample) method, while the accuracy of the method is highly comparable to conventional titrimetric method. Since the implementation of an PTA-UV/VIS setup in any plating industry is cost effective and easy to operate, the analytic method described in this paper may be applied directly for in situ analysis of plating solutions.

  • PDF

Effects of Selective Light Sources on Seedling Quality of Tomato and Cucumber in Closed Nursery System (폐쇄형 육묘시설 내에서 몇 가지 광원이 토마토와 오이의 묘소질에 미치는 영향)

  • Um, Yeong-Cheol;Jang, Yoon-Ah;Lee, Jun-Gu;Kim, Seung-Yu;Cheong, Seung-Ryong;Oh, Sang-Seok;Cha, Seon-Hwa;Hong, Seong-Chang
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.370-376
    • /
    • 2009
  • To produce uniform seedlings of tomato and cucumber with inexpensive way, their seedling quality by different light sources was investigated. The raising of seedling was performed by red LED (light emitting diodes), blue LED, red-blue mixed LED or fluorescent light with a fixed PPF(photosynthetic proton flux) level, about $40{\sim}60{\mu}mol{\cdot}m^{-2}{\cdot}sec^{-1}$. In the both tomato and cucumber, the rapid extension of hypocotyledonary axis was observed in Blue LED than fluorescent light, but opposite result was found in Red and mixed LED. During the nursery period of tomato and cucumber, the fresh weight was the highest in Red LED as 74% increasement in tomato and 74% in cucumber. In the case of seedling quality after the tomato nursery, there was no difference in the positions of 1st flower cluster and the number of bearing-flower per flower cluster by each light source. In case of cucumber, until 20th node, the setting ratio of female flower was higher in LED than fluorescent treatment, and also more healthy fruit setting was found in LED. Therefore, we assume that the Red or mixed (Red 2 + Blue 1) LED is more favorable to produce high quality tomato and cucumber seedlings in closed nursery facility.

Present Status and Future Aspects of Radiation Oncology in Korea (방사선 치료의 국내 현황과 미래)

  • Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.211-216
    • /
    • 2006
  • $\underline{Purpose}$: An analysis of the infrastructure for radiotherapy in Korea was performed to establish a baseline plan in 2006 for future development. $\underline{Materials\;and\;Methods}$: The data were obtained from 61 radiotherapy centers. The survey covered the number of radiotherapy centers, major equipment and personnel. Centers were classified into technical level groups according to the IAEA criteria. $\underline{Results}$: 28,789 new patients were treated with radiation therapy in 2004. There were 104 megavoltage devices in 61 institutions, which included 96 linear accelerators, two Cobalt 60 units, three Tomotherapy units, two Cyberknife units and one proton accelerator in 2006. Thirty-five high dose rate remote after-loading systems and 20 CT-simulators were surveyed. Personnel included 132 radiation oncologists, 50 radiation oncology residents, 64 medical physicists, 130 nurses and 369 radiation therapy technologists. All of the facilities employed treatment-planning computers and simulators, among these thirty-two percent (20 facilities) used a CT-simulator. Sixty-six percent (40 facilities) used a PET/CT scanner, and 35% (22 facilities) had the capacity to implement intensity modulated radiation therapy. Twenty-five facilities (41%) were included in technical level 3 group (having one of intensity modulated radiotherapy, stereotactic radiotherapy or intra-operative radiotherapy system). $\underline{Conclusion}$: Radiation oncology in Korea evolved greatly in both quality and quantity recently and demand for radiotherapy in Korea is increasing steadily. The information in this analysis represents important data to develop the future planning of equipment and human resources.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Spectra Responsibility of Quantum Dot Doped Organic Liquid Scintillation Dosimeter for Radiation Therapy

  • Kim, Sung-woo;Cho, Byungchul;Cho, Sangeun;Im, Hyunsik;Hwang, Ui-jung;Lim, Young Kyoung;Cha, SeungNam;Jeong, Chiyoung;Song, Si Yeol;Lee, Sang-wook;Kwak, Jungwon
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.226-231
    • /
    • 2017
  • The aim is to investigate the spectra responsibilities of QD (Quantum Dot) for the innovation of new dosimetry application for therapeutic Megavoltage X-ray range. The unique electrical and optical properties of QD are expected to make it a good sensing material for dosimeter. This study shows the spectra responsibility of toluene based ZnCd QD and PPO (2.5-diphenyloxazol) mixed liquid scintillator. The QDs of 4 sizes corresponding to an emission wavelength (ZnCdSe/ZnS:$440{\pm}5nm$, ZnCdSeS:470, 500, $570{\pm}5nm$) were utilized. A liquid scintillator for control sample was made of toluene, PPO. The Composition of QD loaded scintillators are about 99 wt% Toluene as solvent, 1 wt% of PPO as primary scintillator and 0.05, 0.1, 0.2 and 0.4 wt% of QDs as solute. For the spectra responsibility of QD scintillation, they were irradiated for 30 second with 6 MV beam from a LINAC ($Infinity^{TM}$, Elekta). With the guidance of 1.0 mm core diameter optical fiber, scintillation spectrums were measured by a compact CCD spectrometer which could measure 200~1,000 nm wavelength range (CCS200, Thorlabs). We measured the spectra responsibilities of QD loaded organic liquid scintillators in two scintillation mechanisms. First was the direct transfer and second was using wave shifter. The emission peaks from the direct transfer were measured to be much smaller luminescent intensity than based on the wavelength shift from the PPO to QDs. The emission peak was shifted from PPO emission wavelength 380 nm to each emission wavelength of loaded QD. In both mechanisms, 500 nm QD loaded samples were observed to radiate in the highest luminescence intensity. We observed the spectra responsibility of QD doped toluene based liquid scintillator in order to innovate QD dosimetry applicator. The liquid scintillator loading 0.2 wt% of 500 nm emission wavelength QD has most superior responsibility at 6 MV photon beam. In this study we observed the spectra responsibilities for therapeutic X-ray range. It would be the first step of innovating new radiation dosimetric methods for radiation treatment.

Surface Chemical Aspects of Coagulation, Deposition, and Filtration Processes: Variation of Electrokinetic Potential at Metal Oxide-Water and Organic-Water Interfaces in the $Na^+$ and $Ca^{2+}$ Ion Solutions

  • Kim, Sung-Jae
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.3
    • /
    • pp.173-183
    • /
    • 2000
  • This study measured the zeta potential of both latex colloidal particles with carboxylate surface groups and glass beads (collectors) with silanol surface group employing various solution with different chemical characteristics. The results have been compared with the surface chemistry theory. The zeta potential of the particle and collector increased with increasing pH up to 5.0 regardless of the solution chemistry. For a monovalent electrolyte solution(sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (calcium chloride solution). In other words, the more the pH decreases, the larger the effect of neutral salts, such as NaCl and CaCl$_2$, have on the ζ-potential values. In this study, the PZPC(point of zero proton condition) of the particle and collector occurred below a pH of 3.1, H(sup)+ and OH(sup)- acted as a PDI (potential determining ion), and Na(sup)+ acted as an IDI(indifferent ion). The magnitude of the negative ζ-potential values of the particle and collector monotonically increased as the concentrations of Na(sup)+ or Ca(sup)2+([Na(sup)+] or [Ca(sup)2+]) decreased (the values of pNa or pCa increased). In the case of latex particles, the ζ-potential should aproach zero (isoelectric point; IEP) asymptotically as the pNa approaches zero, while in the case of calcium chloride electrolyte, ζ-potential reversal may be expected to occur around 3.16$\times$10(sup)-2MCaCl$_2$(pCa=1.5). pH, valance and ionic strength can be used in various ways to improve the water treatment efficiency by modifying the charge characteristics of the particle and collector. Predictive capability is far less certain when EDL(electrical double layer) repulsive forces exist between the particle and collector.

  • PDF

The Removal Characteristics of Cs$^{+}$ and Co$^{++}$ from Aqueous Wastes by Ultrafiltration in Combination with Chemical Treatment Techniques(II) (화학처리와 한외여과막의 결합공정에 의한 Cs 및 Co의 제거특성 (II))

  • 이근우;정경환;김길청;김준형
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.56-64
    • /
    • 1996
  • The objective of this investigation is to establish the rejection characteristics of caesium and cobalt from radioactive liquid waste by chemical/ultrafiltration process. An extensive experimental investigation was conducted with inactive caesium and cobalt ions, utilizing ultrafiltration stirred cell. Caesium and cobalt could be effectively removed from waste solution using copper ferrocyanide and polyarcylic acid(PAA). The rejection dependence of the caesium was found to be a function of caesiun to potassium copper ferrocyanide feed molar ratio. The binding behavior of caesium on K$_2$Cu$_3$(Fe(CN)$\sub$6/)$_2$, particles was explained in terms of a Langmuir adsorption isotherm. When Cs/K$_2$Cu$_3$(Fe(CN)$\sub$6/)$_2$molar ratio was 1.5, the removal of caesium was the most efficient. The rejection efficiency of cobalt is dependent upon various parameters such as pH, cobalt concentration and PAA concentration. The rejection behavior of cobalt was explained in term of a equilibrium model taking into account the reaction between the ligand group, the proton and the cobalt ion. At the conditions of PAA/Co ratio of 2 and pH of 5.6, the removal of cobalt was over 90%. Also, the effect of chemical addition sequence for the simultaneously removal of caesiun and cobalt was discussed.

  • PDF

Study on Staffing of Medical Physicist in the Field of Radiation Therapy (방사선치료분야에서 의학물리사의 적정인력 분석)

  • Hwang, Ui-Jung;Lim, Young Gyung;Kim, Dong Wook;Shin, Dong Oh;Kim, Sung Kyu;Jung, Haijo;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Recently, an adequate number of qualified medical physicist is needed for achieving effective treatment and securing safety to the patient, staff and the public on the course of radiation therapy, since the equipment and the technique of radiation therapy are being developed fast and becoming complex. The studies on medical physics staffing level in United State and European countries were investigated. These results were applied to the domestic situation in order to anticipate indirectly the adequate number of medical physicist in Korea. The current number of medical physicists of 6 (middle to large sized) hospitals in Korea was less than 50% of number recommended in the study. Further detailed research specified on the domestic situation is needed in order to expect adequate number of medical physicist more accurately, and particle beam therapy has to be also considered in the research since the facility site is increasing gradually.

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

The Korean Cough Guideline: Recommendation and Summary Statement

  • Rhee, Chin Kook;Jung, Ji Ye;Lee, Sei Won;Kim, Joo-Hee;Park, So Young;Yoo, Kwang Ha;Park, Dong Ah;Koo, Hyeon-Kyoung;Kim, Yee Hyung;Jeong, Ina;Kim, Je Hyeong;Kim, Deog Kyeom;Kim, Sung-Kyoung;Kim, Yong Hyun;Park, Jinkyeong;Choi, Eun Young;Jung, Ki-Suck;Kim, Hui Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.1
    • /
    • pp.14-21
    • /
    • 2016
  • Cough is one of the most common symptom of many respiratory diseases. The Korean Academy of Tuberculosis and Respiratory Diseases organized cough guideline committee and cough guideline was developed by this committee. The purpose of this guideline is to help clinicians to diagnose correctly and treat efficiently patients with cough. In this article, we have stated recommendation and summary of Korean cough guideline. We also provided algorithm for acute, subacute, and chronic cough. For chronic cough, upper airway cough syndrome (UACS), cough variant asthma (CVA), and gastroesophageal reflux disease (GERD) should be considered. If UACS is suspicious, first generation anti-histamine and nasal decongestant can be used empirically. In CVA, inhaled corticosteroid is recommended in order to improve cough. In GERD, proton pump inhibitor is recommended in order to improve cough. Chronic bronchitis, bronchiectasis, bronchiolitis, lung cancer, aspiration, angiotensin converting enzyme inhibitor, habit, psychogenic cough, interstitial lung disease, environmental and occupational factor, tuberculosis, obstructive sleep apnea, peritoneal dialysis, and idiopathic cough can be also considered as cause of chronic cough. Level of evidence for treatment is mostly low. Thus, in this guideline, many recommendations are based on expert opinion. Further study regarding treatment for cough is mandatory.